Note: 

DC power coming to the WF-8930/50 Series Distribution Center could be routed in one 

of 2 ways. 

1.   Power could be coming directly into the WF-8930/50 Series Distribution Center fuse board 

from the converter/charger. The battery (if supplied) would also connect to the fuse board.

2.   Power from the converter charger would be connected directly to the battery. A cable from 

the battery would be connected to the fuse boards input lugs.

We’ll use the first connection method in our discussion below.

Connect the heavy Positive wire coming from the converter/charger to one of the 

POS+

 lugs of 

the fuse board. In a similar fashion, connect the heavy Negative wire from the converter/charger 

to the 

NEG-

 lug on the fuse board. Make sure the lugs are tightened to the specs in the torque 

chart locate on the back of the door assembly. Connect the battery Positive cable to the 

remaining 

POS+ 

lug making sure it is torqued properly. The Negative battery lead will be 

connected below.

As a last step, any DC negative leads should be connected to the internal Negative bus bars 

located at the bottom left of the fuse board. 

CONSUMER LIMITED WARRANTY
for WFCO Electronic Products

WFCO extends, to the original owner, a Two Year Limited Product Warranty. This 

warranty is in effect from the date of original purchase for a period of two (2) years. This 

limited warranty is extended specifically for and is limited to Recreational Vehicle 

application and is only valid within the continental United States, Alaska, Hawaii and the 

Provinces of Canada. WFCO warrants, to the owner, that its products are free from defects 

in material and workmanship under normal use and service based on its intended use and 

function. This warranty is limited to the repair or replacement, at WFCO’s discretion, of any 

defective parts or defective assembly. Any implied warranties of merchantability or fitness 

for intended use are limited in duration unless applicable State Law provides otherwise. You 

may have other rights as specified by each individual state.

EXCLUSIONS and LIMITATIONS

The OEM warranty specifically does not apply to the following: 
•  Any WFCO product that has been repaired or altered by an unauthorized person; 

•  Any damage caused by misuse, faulty installation, testing, negligence, accident or any  

    WFCO product installed in a commercial vehicle;

•  Any WFCO product, whose serial number has been defaced, altered or removed; 

•  Any WFCO product, whose installation has not been in accordance to the WFCO  

    written instructions; 

•  Any consequential damages arising from the loss of use of the product including but not  

    limited to: inconvenience, loss of service, loss of revenue, loss or damage to personal  

    property, cost of all services performed in removing or replacing the WFCO product.  

    Specifications are subject to change without notice or obligation.

•  Any WFCO Electronics products sold through unauthorized Internet sources  

    (Example: eBay) will be excluded from all warranty coverage offered by Arterra  

   Distribution / WFCO. 

10

Содержание WF-8930/50 Series

Страница 1: ...8997 Warranty warranty wfcoelectronics com Fax 574 294 8698 www wfcoelectronics com Power PROs Technical Support 877 294 8997 WF 8930 50 Series Distribution Centers WF 8930 50NP WF 8930 50NP 30 The Distribution Center model number is located on the front panel label near the AC breakers ...

Страница 2: ...in Circuit Breaker List 4 UL Listed Branch Circuit Breaker List 5 TROUBLESHOOTING INSTRUCTIONS Check Converter or Battery Input Voltage 6 Blown Fuse Indicators 6 GENERAL COMPLIANCE INFORMATION Agency Listings 7 INSTALLATION INSTRUCTIONS Mounting the Enclosure 7 Wiring the AC Breakers 8 Wiring the DC Fuse Board 9 WARRANTY INFORMATION 10 TABLE OF C ONTENTS 2 ...

Страница 3: ...cation and replacement instructions Blown Fuse Indicators on DC Fuse Board The DC Fuse Board has individual blown fuse indicators as standard equipment The WF 8930 50 Series Distribution Centers have 15 DC circuits Each of the circuits contain a Red LED to indicate a blown fuse If one of the circuits draws more current than the rating of the fuse the fuse will blow When this occurs the Red LED for...

Страница 4: ...eries Distribution Center accepts standard residential breakers The WF 8930 50NP has spaces for two 50 Amp or one 30 Amp Main breakers and up to 12 Branch breakers when using duplex breakers The WF 8930 50NP 30 has spaces for a 30 Amp Main and up to 6 Branch breakers when using duplex breakers A list of factory tested and approved breakers follows The breakers may be purchased at most big box depa...

Страница 5: ... C Type BRD BD and A Thomas Betts Type TB or TBBD ITE Siemens Type QP or QT Square D Type HOM or HOMT Murray Type MP T or MH T General Electric Type THQL When replacing any of the installed circuit breakers the replacement should be of the same manufacturer type designation and equal interrupting rating not to exceed 30 A The Short Circuit Current rating for the breaker should be 10 000 Amps Break...

Страница 6: ... lug and place the Negative black meter probe on the NEG lug If the voltage from the converter charger reads approximately 13 6 VDC 0 2 at the lugs the fuse board is getting DC power If no converter charger battery input voltage is read at these lugs check for an open inline fuse or disconnect switch in circuit coming to the fuse board One may have been installed by the RV manufacturer Also check ...

Страница 7: ...d for return label and disconnect each wire as it is removed from the fuse board lug Follow the packaging instructions in your warranty claim packet GENERAL COMPLIANCE INFORMATION Agency Listings UL The WF 8930 50 Series Distribution Centers are UL Listed and cUL Listed Canadian TROUBLESHOOTING INSTRUCTIONS 7 INSTALLATION INSTRUCTIONS Installing the WF 8930 50 Series Distribution Center Mounting t...

Страница 8: ... when using duplex breakers Refer to the tables on pages 4 and 5 for a selection of approved breakers The Main breakers should be installed in the center position See the wiring diagrams below A hold down clip is provided to keep the breaker securely in place The Shore cord should be routed through one of the large knockouts in the back of the wiring compartment as indicated above and secured with...

Страница 9: ...r current loads and can have a maximum 30 Amp ATO or ATC fuse installed The remaining 13 circuits are general purpose and can have up to a 20 Amp ATO or ATC fuse installed Make sure the fuses are seated properly All models have lug screw connections Strip approximately 1 4 of insulation from the DC load wires and insert the wire into the appropriate lug Tighten the lug screw to the torque spec fou...

Страница 10: ...ted to Recreational Vehicle application and is only valid within the continental United States Alaska Hawaii and the Provinces of Canada WFCO warrants to the owner that its products are free from defects in material and workmanship under normal use and service based on its intended use and function This warranty is limited to the repair or replacement at WFCO s discretion of any defective parts or...

Страница 11: ...y Department at 574 294 8698 After receipt of the forms an RGA number will be issued This number shall appear on all correspondence with warranty service Upon validation of the warranty WFCO shall replace the product with a like product The RGA number shall be placed on the outside of the carton used to return the product for ease of identification Do not mark directly on the product The product m...

Страница 12: ...W F C O E L E C T R O N I C S C O M ...

Отзывы: