background image

 

IN

S

T

A

L

L

A

T

IO

N   I

N

S

T

R

U

C

T

IO

N

S

 

 

 

OEM Installation of the WFCO WF-6800 Series 
Deckmount Converter

Select a mounting location near the shore power and battery (batteries).

- Do not mount in an area where the owner may store items, as this 
could reduce the clearance requirements, obstruct ventilation
openings and affect the efficient operation of the converter.

- Horizontal mounting of the 6800 series is recommended although it 
can be mounted in any position that provides unobstructed ventilation
for the fan and vent holes. Secure the converter firmly to the mounting 
surface using standard fasteners. For propper operation the converter 
must be grounded to the chassis or frame. A ground lug is provided on
the side of the converter.
 
- Select a mounting location that is appropriate to prevent excessive 
heat, water, moisture, dust and dirt entering the unit installed.  Allow 
a minimum of two cubic feet of clear airspace and any additional 
venting as necessary to prevent the unit from overheating.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, 
REPLACE ONLY WITH THE SAME TYPE AND RATING FUSE.

The fuse rating that the manufacturer suggests for the output fuses
will be marked on the unit. Replace only with same type and rating.

During the manufacturing process, be sure that all converter openings 
are protected from debris falling into the unit. 

NOTE: 

If the reverse battery protection fuses are blown during 

installation, be sure that the battery has been connected properly, then 
replace the fuses with “ATC-style” fuse with the same rating as the 
original. 

WARNING

!

!

CAUTION

!

!

This equipment employs components that tend to produce arcs or sparks. 

To prevent fire or explosion, 

DO NOT INSTALL IN COMPARTMENT CONTAINING 

BATTERIES OR FLAMMABLE MATERIALS (LP gas)

.

 

2

3

 

S

P

E

C

IF

IC

A

T

IO

N

S

   

 

E

D

POS+

NEG-

FUSE

FUSE

FUSE

WF-6800 Series Converter Dimensions

A:

 13.36? 

B: 

7.87

C

1

:

 2.56

D

: 9.96? 

E

: 3.89?

?

?

C

2

:

 2.93?

A

B

Dimensions

C

2

C

1

REVERSE POLARITY 
       FUSES USED:

WF-68100 - 40/40/40 Amps

20A Power Cord