background image

INSTALLATION INSTRUCTIONS

1.   Open Carton and Inspect Parts

   Installation Parts included – refer installation  

diagram. 

 

ITEM NO. 

DESCRIPTION

 

 

K-AU1000 Head Assembly 

  

with mounting bracket

 

 

C-AU1000 Quick Change Filter  
Cartridge 

  

 

Connection fitting to cold water  
cistern tap 

 

 

Isolation valve 

 

 

Pressure Limiting Valve 

 

 

Quick Connect ¼ ” Elbow fittings 

 

 

Quick Connect Locking Clips

 

 

Tubing ¼”

 

 

Chrome Filter Tap 

 

 

Mounting Screws 

 

 

Filter Monitor Alarm

2.   ENSURE THAT THE COLD WATER IS 

TURNED OFF

  •   Under the kitchen sink locate the cold  

water isolation tap/valve. 

  •   Turn the cold water off (check at main  

kitchen tap that water is fully turned off  
– if not, turn off at mains supply). 

  •   Unscrew the braided flex hose from the 

existing cold water isolation tap/valve. 

  •   Clean the ½” male bsp water connection thread.

3.   Under-sink Mounting Position for Head 

Assembly

  •   Remove the Head Assembly (1) and Filter 

Cartridge (2) from the carton. 

  •   Insert cartridge into head assembly and  

lock/twist until tight.

  •   Find a suitable location for the filter head 

and cartridge on the back or side wall of the 
under-sink kitchen cupboard – mark this 
location. Don’t forget to allow at least 50 mm 
underneath the bottom of the filter cartridge to 
allow for filter replacement. Please ensure that 
the location of the filter system is close to the 
cold water connection and below where the 
filter tap will be placed.

  •   Make sure that there is adequate space to 

avoid crimping the water line plastic tubing. 

4.   Connect Fittings to Cold Water Cistern Tap  

(item 3 & 4)

  •   Apply plumbing tape to the existing ½” male 

bsp water connection cistern tap fitting before 
screwing on the connection fitting (3).

  •   Also apply plumbing tape to the ½” male bsp 

connection on the outlet of the connection 
fitting (3). Wrap tape in direction of the threads 
to ensure a tight fit and avoid leaks. 

  •   Re-Connect the ½” female bsp end of the 

existing cold water hose to the ½” male bsp 
end of the connection fitting. 

  •  Take isolation valve (item 4) and wrap 

plumbing tape around male bsp end. Screw 
into connection fitting (item 3) ensuring that 
the connection is sealed and tight.

5.  Install the Filter Tap

  •    Remove filter tap from carton and assemble 

as shown below;

  •   Locate your filter tap position and drill a 

12.7mm (½”) hole in the sink or benchtop to 
accommodate the filter tap.

  •  Install the filter tap

6.  Inlet/Outlet Connection fittings

  •  Take the two quick connect ¼” elbow fittings 

(item 6). Apply plumbing tape to threaded 
male end and screw into inlet and outlet side 
of filter head assembly (item 1).

7.  Mount Filter Head under Sink

 

•  Secure filter head, cartridge and mounting 

bracket with screws provided in desired 
location.

8.   Connect Tubing to cold water inlet, Pressure 

Limiting Valve (PLV) and inlet of Head 
Assembly

•  Remove plastic tubing from carton.
•   The Pressure Limiting Valve (item 5) is 

connected between the isolation valve (item 4) 
and the Head Assembly (item 1).

•   Measure the desired length of tubing from the 

isolation valve to the inlet of the PLV.

•   Cut tubing using Stanley knife or similar ensuring 

the cut is square and clean.

•   Remove tightening nut from isolation valve and 

place over tubing then over isolation valve nipple 
- secure with tightening nut.

•   Take other end of tube and insert into inlet of 

PLV - push in tightly then pull back to ensure 
firm connection.

•   When pulling back plastic tubing, take a Quick 

Connect Locking Clip (item 7) and secure it 
behind the round collet to secure fitting - refer 
installation diagram.

•   Measure length of the tube from the outlet of the 

PLV to the inlet of the filter head assembly and 
repeat the process.

•   The Quick Connect Locking Clips should be 

used on the two PLV connections, two head 
connections and one tap adaptor connection.

9.   Connect Tubing to outlet of Head Assembly 

and to filter tap

  •   Measure length of tube from the outlet of the 

head Assembly (right hand side) to the base 
of the filter tap making sure that there are no 
kinks in the tubing.

  •   Cut tubing to desired length using Stanley 

knife or similar ensuring that the cut is square 
and clean.

  •   Insert tube end into the Head Assembly “push 

fit” connection on the outlet of the Head 
assembly (right hand side). Push the tube in 
tightly so that its firm – pull back on tube to 
secure - insert locking clip.

  •   

At other end insert tube into tap adapter. Push 
tube in tightly so that it’s firm - pull back on 
tube to secure - insert locking clip.

  •   Screw onto threaded base of the filter tap – 

secure tightly.

10. Flush the Filter Cartridge

  •   Turn mains water supply back on at mini 

cistern tap.

  •  Open cold water line at the isolation valve
  •   At this stage check for leaks and fix if 

necessary

  •   Turn filter tap on and flush the filter cartridge 

for at least 3 minutes. Collect water in 
container and use for garden etc.

NOTE – Flushing the filter cartridge is important 
to remove air from the system and any loose 
carbon. At first the water may appear cloudy 
due to compressed trapped air in the filter and 
hoses. However the cloudiness will disappear 
over time and with use.

11.   Installing the Filter Monitor Alarm (item 11)

   The filter monitor alarm (item 11) is supplied 

to assist you with knowing when it is time to 
replace your filter cartridge. Regular annual 
cartridge replacement ensures that your filter 
system is maintained in accordance with the 
manufacturers recommendations.

  a)  Remove double sided tape and plastic 

wrapper from monitor.

  b)  On the back of the monitor - Pull the tab 

back.

  c)  The LED and buzzer will cycle 3 times to 

confirm the start.

  d)  It is programmed to flash and sound again in 

12 months.

  e)  Remove the two adhesive tapes from the 

back of the monitor and locate/mount in a 
convenient location under your kitchen sink.

 NOTES

 

1)   This installation must comply with all 

applicable state and local regulations

  2)   Do not use with water that is 

microbiologically unsafe or of an unknown 
quality without disinfection before or after 
the system.

  3)   When storing filtered water in a 

refrigerator please ensure the container has an 
air tight seal / lid.

Unit Description, Permitted Use and 
Manufacturers Instructions for Use:

Unit Description:

  

K-AU1000

Product Specifications:

 

The unit must only be used for a potable water 
source and with cold water (with a temperature 
range between 5 and 38 degrees C). This unit 
must be installed in accordance with state and 
local laws.

Warranty

Water Filters Australia Pty Limited, Unit 1, 91-93 
Old Pittwater Road, Brookvale, NSW Australia 
2100 warrants to you, the first person who has 
purchased and used the unit (“you”) that this unit 
is free from defects due to faulty material and 
workmanship in accordance with the conditions 
set out in this document.

What this warranty covers:

This warranty covers defects due to faulty 
material and workmanship of the unit supplied 
to you:

•   For a period of 1 year from the date of 

purchase in respect of the entire unit, 
excluding the Replaceable Elements

The Replaceable Elements are consumable 
components and all parts of the unit which can 
be replaced including but not limited to the filter 
or water treatment cartridge if there is a defect in 
the filter or cartridge. This does not include the 
replacement of the filter or cartridge to extend 
the life of the filter or cartridge. The life of the filter 
cartridge is affected by water quality, usage and 
water pressure.

The warranty only extends to the original 
purchaser of the unit.

What this warranty does not cover:

This warranty does not cover the unit or a 
Replaceable Element of the unit where:
•   The defect, fault or failure is attributable, or 

substantially attributable to misuse, abuse, 

accident, misapplication, neglect, freezing, 
oxidizing agents (including but not limited to 
chlorine, ozone, chloramines and other related 
components) or act of God;

•   The unit has been in conditions which do 

not conform to the recommended design 
guidelines or has been operated in a manner 
which is contrary to WFA’s printed instructions;

•   The unit has not been installed in accordance 

with WFA’s printed instructions and has not 
been installed in compliance with all applicable 
laws, regulations and industry standards;

•   The unit has not been used in accordance with 

the manufacturers instructions;

•   The unit does not meet the conditions for use 

described in the owners guide or performance 
data sheet for this unit;

•   You use accessories or components which do 

not meet WFA’s specifications as set out in the 
Installation and Operating Manual;

•   The defect, fault or failure is due to normal 

wear and tear;

•   The defect, fault or failure has occurred where 

the unit has been used reasonably or has 
reached its serviceable life;

•   The serial or model number label of the unit is 

removed or defaced;

•   The unit is serviced, modified, altered or 

repaired by an unauthorized or unqualified 
person;

•   You have received incorrect advice from the 

retailer or authorized dealer about the suitability 
or capability of the unit;

The cost of freight for or relating to the repair or 
replacement of the Replaceable Element or the 
unit must be paid by you.

How to make a claim under this warranty:

To make a claim under this warranty you must 
contact WFA within 21 days of the defect, fault or 
failure occurring. WFA Warranty Contact number 
is 1300 785 355 or alternatively contact us via 
email [email protected] or by mail via 
PO Box 636, Freshwater NSW 2096.

At the time of repair or replacement under your 
warranty claim you must provide to WFA:
•   Proof that you purchased the unit from an 

authorized retailer or dealer within the warranty 
time; and

•   A copy of a certificate which certifies that 

the unit was installed in compliance with 
our printed installation instructions and all 
applicable laws, regulations and industry 
standards.

WFA will only pay for repair or replacement upon 
receipt of proof of your purchase showing the 
date of purchase.

Limitation of Liability of WFA under this 
warranty:

Where a warranty exists or is implied by law, 
WFA’s liability is limited (to the extent that it can 
be limited) to repair or replacement of the faulty 
Replaceable Element or the unit or an equivalent 
unit. WFA may, in its discretion, choose whether 
it shall repair or replace any unit or Replaceable 
Element or WFA may choose to pay to you the 
cost of replacing the Replaceable Element or the 
unit or the cost of having the unit repaired.
To the extent permitted by law, WFA assumes no 
liability whatsoever and disclaims all liability for 
direct, indirect or consequential loss, or special, 
general or other damage or expense caused by 
or arising out of:
•   Any failure to install or use the unit in 

accordance with the Manufacturers 
Instructions, the Installation and Operating 
manual or WFA’s printed instructions; or

•   The purpose for which you are purchasing the 

unit.

You acknowledge that the quality of water supply 
and your water usage rate and influent water 
pressure may vary seasonally or over a period of 
time. In addition to this water characteristics can 
differ if the unit is relocated or the environment 
changes.
You acknowledge that WFA does not know your 
requirements and cannot and does not warrant 
that the unit is fit for the purpose for which you 

intend to use the unit or is appropriate for the 
purpose for which you intend to use the unit.
WFA does not authorize others to assume any 
obligation on its behalf even if you inform them of 
the purpose for which you intend to use this unit.
Our goods come with guarantees that cannot 
be excluded under the Australian Consumer 
Law. You are entitled to a replacement or refund 
for a major failure and for compensation for any 
other reasonably foreseeable loss or damage. 
You are also entitled to have the goods repaired 
or replaced if the goods fail to be of acceptable 
quality and the failure does not amount to a major 
failure.

Warning
WFA does not recommend making alterations to 
your existing plumbing to accommodate this filter 
system. If you wish to modify existing plumbing 
you must comply with AS 3500 and use a 
licensed plumber.

Where internal water pressure exceeds 600 kPa 
a Watermark approved Pressure Limiting Valve 
must be installed prior to the filter system.

Warning
The contaminants or other substances removed 
or reduced by this water treatment system are 
not necessarily in your water supply. Do not use 
with water that is microbiologically unsafe or of 
an unknown quality without disinfection before or 
after the system.

Important
This filter is designed to be used with mains/city 
disinfected water supplies. 

Caution
Safely isolate the water supply prior to installing 
the filter system to avoid injury and property 
damage.

Owners Manual

Water Filter System

WARRANTY

Отзывы: