WD-ACS 47D
Rev. 1.0 (202003)
Installation instructions
14
3.6.3
Ventilation
The machine’s heat load for the room is stipulated in TECHNICAL SPECIFICA-
TIONS.
The machine has a condensing battery connected to an exhaust fan to reduce the
amount of steam released. Extractor fans for extracting steam can be installed
above the infeed and outfeed openings, as well as above the area of the machine
where steam is emitted from the condensing fan.
If a hood is fitted over the machine, it must cover both the infeed and the outfeed.
The front of the hood must be positioned at least 500 mm in front of the machine
to allow access for service and repairs.
3.6.4
Steam connection (option)
The connection for steam (8) is fitted with a filter. The machines are supplied as
standard without a shut-off valve for steam. A shut-off valve must be installed on
the incoming pipe.
3.6.5
Condensing water connection (option)
A connection for condensation (7) is only provided on steam-heated machines.
The pipe is connected to the system’s steam boiler.
3.6.6
Drain/waste pipe
The waste water system connected to (5) should consist of a 50 mm metal pipe
that will withstand mechanical impacts. The drain must run to a floor drain (6),
where its opening must be above the water level.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.