background image

 

 

Safety Notes 

 

Please note the following safety notes to avoid malfunctions, 
damage or physical injury: 

  This manual belongs to the product. It contains important notes 

on operating the unit. Please pass it on along with the unit if it is 
handed over to a third party! 

  Dispose of the packaging materials carefully; the plastic bags may 

become a deadly toy for children. 

  Please make sure the voltage stated on the type label corre-

sponds to the voltage of the application to be measured. 

  The unit meets measurements in measuring category 

III

. Do not 

use the unit for undertaking measurements in the measuring 
category 

IV

 (explanation see next chapter). 

  Do not continue to use the unit if the unit or the measuring probes 

are damaged. Repair work must be done by a qualified service 
technician. 

  Carry out measurements only on an insulated floor, in dry clothing 

and wearing rubber shoes (or standing on a rubber mat). Do not 
touch any metallic objects. 

  Do not touch bare wires or live parts during measurements. 

  Do not conduct the line cords  over sharp edges and corners or 

hot surfaces. 

  Observe the technical date and do not operate the unit beyond 

the stated specifications. 

  This field meter is a precision measuring instrument and must be 

handled with care. 

  Do not expose the unit to direct sunlight, humidity, strong 

mechanical stress, dirt, high temperature, strong light or strong 
magnetic fields. 

  Do not disassemble the unit or attempt to repair it yourself. It does 

not contain parts serviceable by you. In the case of questions or 
problems, turn to our customer support. 

Содержание 79 71 59

Страница 1: ...Drehfeld Messgerät Artikel Nr 79 71 59 Rotating Field Meter Article No 79 71 59 Bedienungsanleitung Instruction Manual ...

Страница 2: ...r you to handle the unit appropriately and help prevent misunderstandings and possible damage Dieses Drehfeld Messgerät ist ideal zum Ermitteln der Phasenlage in allen Bereichen in denen Dreiphasen Stromversorgungen zum Betreiben von Antrieben Motoren und elektrischen Systemen eingesetzt werden Ob die drei Phasen und die Phasen Drehrichtung korrekt sind zeigt das Gerät über die LEDs an Bitte mache...

Страница 3: ...III Übersicht Overview Phasenanzeige Phase Indicators Phasen Drehrichtung Phase Rotating Direction ...

Страница 4: ...ge 8 Measurement Page 8 Hints Page 9 Cleaning Page 10 Technical Data Page 11 Sicherheitshinweise Seite 1 Messkategorien Seite 2 Symbolerklärung Seite 2 Vor der ersten Benutzung Seite 3 Messung Seite 3 Hinweise Seite 4 Reinigung Seite 4 Technische Daten Seite 5 Table of Contents Inhaltsverzeichnis ...

Страница 5: ...uell Gummischuhen oder auf Gummimatte stehend durch Berühren Sie keine metallischen Gegenstände Berühren Sie beim Messen keine blanken Drähte oder spannungs führende Teile Führen Sie die Prüfleitungen nicht über scharfe Ecken und Kanten oder heiße Oberflächen Beachten Sie die technischen Daten und betreiben Sie das Gerät nicht außerhalb seiner Spezifikationen Das Drehfeld Messgerät ist ein Präzisi...

Страница 6: ...in Gebäudeinstallationen vorgesehen Beispiele sind Messungen an Verteilerkästen Unter brechern Verdrahtungen Anschlussleisten Verbindungsboxen Schaltern und Steckdosen der festen Hausinstallation aber auch für Messungen an industriellen Geräten und Ausrüstungen wie z B fest installierte Motoren Die Messkategorie IV ist für die Messung an der Quelle der Niederspannungsinstallation wie z B Zähler od...

Страница 7: ...e L1 U L2 Messleiter an die Phase L2 V L3 Messleiter an die Phase L3 W Achten Sie darauf die Messspitzen nicht zu berühren Es besteht die Gefahr eines elektrischen Schlages Achtung Lebensgefahr Halten Sie die Finger immer hinter dem Fingerschutz auf den Mess leitungen 3 Anhand der aufleuchtenden LEDs können Sie erkennen ob die 3 Phasen korrekt angeschlossen sind und die Phasen Drehrichtung stimmt ...

Страница 8: ...ln Eine Modifizierung oder Verände rung der internen Schaltkreise ist nicht gestattet Wartungs und Reparaturarbeiten am Gerät dürfen nur von qualifizierten Fachkräften vorgenommen werden Achten Sie darauf dass das Gerät nicht feucht oder nass wird Setzen Sie das Gerät keinen extremen Temperaturen aus und lagern Sie es nur in normal temperierten Räumen Betreiben oder lagern Sie das Gerät nicht in s...

Страница 9: ...sen CAT III 180 bis 480 V Frequenzbereich 20 Hz bis 380 Hz Betriebszeiten 3 Min 15 Min Pause Betriebstemperaturbereich 0 C bis 40 C 32 F bis 104 F Lagertemperaturbereich 10 C bis 50 C 14 F bis 122 F Luftfeuchtigkeit 75 Abmessung 93 x 70 x 30 mm Gewicht 165 g Kabellänge der Messleitungen 115 cm Schutzart IP 20 ...

Страница 10: ...if the unit or the measuring probes are damaged Repair work must be done by a qualified service technician Carry out measurements only on an insulated floor in dry clothing and wearing rubber shoes or standing on a rubber mat Do not touch any metallic objects Do not touch bare wires or live parts during measurements Do not conduct the line cords over sharp edges and corners or hot surfaces Observe...

Страница 11: ...ng measurements on house installations Examples are distribution boxes circuit breakers wiring terminal strips connectors switches and wall sockets of the fixed installations but also for measurements on industrial units and equipment such as permanently installed motors The measuring category IV is intended for taking measurements on the source of the low voltage installation e g electric meters ...

Страница 12: ...probe on phase L1 U L2 Measuring probe on phase L2 V L3 Measuring probe on phase L3 W Make sure not to touch the measuring tips There is risk of electric shock Attention Risk of Life Keep your fingers behind the protection guard of the measuring probes 3 Via lighting up LEDs you can verify whether the 3 phases are connected correctly and the phase rotating direction is correct If all three LEDs fo...

Страница 13: ...he phasing is not correct repair work on 3 phases sockets should be performed by professionals only 5 After measuring reattach the protection caps on the tips of the measuring probes Hints This field meter is a precision measuring instrument and must be handled with care Do not modify the unit or alter the inter nal circuits Maintenance and repair of the unit should only be performed by a qualifie...

Страница 14: ...ts are only guaranteed if the unit is handled with care and well maintained Do not operate the unit in a dusty or dirty environment Cleaning Only clean the unit with a soft moist cloth Make sure the unit is completely dry before using again Only use common mild detergents for cleaning Do not use aggressive chemicals or similar for cleaning ...

Страница 15: ...ases CAT III 180 to 480 V Signal Frequency Range 20 Hz to 380 Hz Operating Times 3 min 15 min break Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 10 C to 50 C 14 F to 122 F Humidity 75 Dimensions 93 x 70 x 30 mm Weight 165 g Cord Length of the Probes 115 cm Degree of Protection IP 20 ...

Страница 16: ... de caoutchouc on position permanents Ne pas toucher des objets métalliques Lors de la mesure ne touchez pas des fils dénudés ou des parties sous tension Ne pas faire passer les sondes de test d arêtes tranchantes et des arêtes vives ou sur des surfaces chaudes Respecter les caractéristiques techniques et ne pas utiliser l appareil en dehors de la zone spécifique L indicateur de phase est un instr...

Страница 17: ... asciutti e possibilmente scarpe di gomma o tappetino di gomma in piedi Non toccare oggetti metallici Quando si misura non toccare fili scoperti o parti in tensione Non far passare i puntali di controllo da spigoli vivi e bordi affilati o su superfici calde Osservare i dati tecnici e non azionare il dispositivo al di fuori delle specifiche riportate Il misuratore di fase è uno strumento di precisi...

Страница 18: ...14 Notizen Notes ...

Страница 19: ...15 Notizen Notes ...

Страница 20: ...16 Notizen Notes ...

Страница 21: ...ed in the European Directives and their amendments 2011 65 EU 2011 65 EU Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro und Elektronikgeräten RoHS Restriction of the Use of certain hazardous Substances in electrical and electronic Equipment RoHS 2004 108 EG 2004 108 EC Elektromagnetische Verträglichkeit EMV Electromagnetic Compatibility EMC EN 61326 1 2013 EN 61326 2 2 2013 ...

Страница 22: ...h Internet www westfalia net Kundenbetreuung Customer Services Werter Kunde bitte helfen Sie mit Abfall zu vermeiden Sollten Sie sich einmal von diesem Artikel trennen wollen so bedenken Sie bitte dass viele seiner Komponenten aus wertvollen Rohstoffen bestehen und wiederverwertet werden können Entsorgen Sie ihn daher nicht in die Mülltonne sondern führen Sie ihn bitte Ihrer Sammelstelle für Elekt...