background image

 

 

IV 

 
 

9

  This manual belongs to the product. It contains important notes on operating the 

unit. Please pass it on along with the unit if it is handed over to a third party! 

9

  Dispose of the packaging materials carefully; the plastic bags may become a deadly 

toy for children. 

9

  Do not pump objects over the specified max. pressure. 

Using 

ƒ

  To activate the air pressure gauge press the function key below the display. The last 

selected measuring unit appears. 

ƒ

  To change the measuring unit press the function key. Each time you press the function 

key the measuring unit change from „Bar“ to „kgf/cm

2

“, „kPa“ and „PSI“ and after that it 

starts from the beginning. 

ƒ

  Select the desired measuring unit (you can also change it additionally), attach the 

pressure gauge opening onto the valve of the tyre and keep the gauge pressed for  
2 seconds. Make sure that no air can leak and the air pressure gauge sits steadily onto 
the valve. 

ƒ

  You can see the readings on the display. If the displayed pressure is too low or too 

high, inflate or deflate. 

ƒ

  To change the measuring unit after gauging, press the function key. 

ƒ

  The air pressure gauge turns off automatically after 30 - 60 seconds. The last 

measured reading will be deleted. To turn off manually, press and hold the function key 
for approx. 5 seconds. 

Changing the battery 

ƒ

  If the battery symbol appears on the right side of the display the battery is spend and 

should be changed directly. 

ƒ

  Unscrew the four screws on the back side of the unit and open the housing. 

ƒ

  Remove the spend battery and place a new one of the same type and dimension (3 V - 

CR-2032), objecting right polarity (Plus pole face up).  

ƒ

  Close the housing again and tight the screws. 

Hint 

Pressure ratings of tyre manufacturers always refer to cold tyre temperature. 

Technical Data 

Measuring Units.......................................... 0 - 100 PSI; 0 -7 Bar; 0 - 7 Kgf/cm

2

; 0 - 700 Kpa 

Power Supply / Battery............................... 1 x 3 V CR-2032 
Operating Temperature .............................. -5 to +50 °C 
Storing Temperature .................................. -20 to +70 °C 
Dimensions (L x W x D).............................. 60 x 40 x 13 mm 
Weight (with Battery) .................................. 24 g 
 

Operating Elements and Using 