IV
9
This manual belongs to the product. It contains important notes on operating the
unit. Please pass it on along with the unit if it is handed over to a third party!
9
Dispose of the packaging materials carefully; the plastic bags may become a deadly
toy for children.
9
Do not pump objects over the specified max. pressure.
Using
To activate the air pressure gauge press the function key below the display. The last
selected measuring unit appears.
To change the measuring unit press the function key. Each time you press the function
key the measuring unit change from „Bar“ to „kgf/cm
2
“, „kPa“ and „PSI“ and after that it
starts from the beginning.
Select the desired measuring unit (you can also change it additionally), attach the
pressure gauge opening onto the valve of the tyre and keep the gauge pressed for
2 seconds. Make sure that no air can leak and the air pressure gauge sits steadily onto
the valve.
You can see the readings on the display. If the displayed pressure is too low or too
high, inflate or deflate.
To change the measuring unit after gauging, press the function key.
The air pressure gauge turns off automatically after 30 - 60 seconds. The last
measured reading will be deleted. To turn off manually, press and hold the function key
for approx. 5 seconds.
Changing the battery
If the battery symbol appears on the right side of the display the battery is spend and
should be changed directly.
Unscrew the four screws on the back side of the unit and open the housing.
Remove the spend battery and place a new one of the same type and dimension (3 V -
CR-2032), objecting right polarity (Plus pole face up).
Close the housing again and tight the screws.
Hint
Pressure ratings of tyre manufacturers always refer to cold tyre temperature.
Technical Data
Measuring Units.......................................... 0 - 100 PSI; 0 -7 Bar; 0 - 7 Kgf/cm
2
; 0 - 700 Kpa
Power Supply / Battery............................... 1 x 3 V CR-2032
Operating Temperature .............................. -5 to +50 °C
Storing Temperature .................................. -20 to +70 °C
Dimensions (L x W x D).............................. 60 x 40 x 13 mm
Weight (with Battery) .................................. 24 g