Station LAN

12 Foot Solid Dish

Broadband

Internet

Decoder #2 Relay Outputs

Pin Function

Pin Function

1 Relay 1

20

2 Relay 2

21 Relay

3 Relay 3

22 Common

4 Relay 4

23

5 Ground

24 Ground

6 Relay 5

25

7 Relay 6

26

8 Relay 7

27 All Relay

9 Relay 8

28 Commons

10 Ground

29 are

11 Relay 9

30 Connected

12 Relay 10

31

13 Relay 11

32

14 Relay 12

33 Ground

15 Ground

34 Relay

16 Relay 13

35 Common

17 Relay 14

36

18 Relay 15

37

19 Relay 16

Note: All Relay commons are ganged inside
the receiver. Conntact JRN if you need
isolated commons for each relay.

Decoder #1 Relay Outputs

Pin Function

Pin Function

1 Relay 1

20

2 Relay 2

21 Relay

3 Relay 3

22 Common

4 Relay 4

23

5 Ground

24 Ground

6 Relay 5

25

7 Relay 6

26

8 Relay 7

27 All Relay

9 Relay 8

28 Commons

10 Ground

29 are

11 Relay 9

30 Connected

12 Relay 10

31

13 Relay 11

32

14 Relay 12

33 Ground

15 Ground

34 Relay

16 Relay 13

35 Common

17 Relay 14

36

18 Relay 15

37

19 Relay 16

Note: All Relay commons are ganged inside
the receiver. Conntact JRN if you need
isolated commons for each relay.

Non-Dedicated Phone Line

If broadband Internet is not available.

Receiver Analog Output #1

1 Left Out (+)

6 Left Out (-)

2 Audio Ground

7 Audio Ground

3 n/c

8 n/c

4 Audio Ground

9 Right Out

5 Right Out (+)

Receiver Analog Output #2

1 Left Out (+)

6 Left Out (-)

2 Audio Ground

7 Audio Ground

3 n/c

8 n/c

4 Audio Ground

9 Right Out

5 Right Out (+)

AP News Output (if Affiliated)

1 AP 2 Min Out (+)

6 AP 2 Min Out (-)

2 Audio Ground

7 Audio Ground

3 n/c

8 n/c

4 Audio Ground

9 AP 3 Min Out (-)

5 AP 3 Min Out (+)

RBDS Data 1

2 RxD Data Out +

5 Ground

RBDS Data 2

2 RxD Data Out +

5 Ground

** Future Feature

** Future Feature

AES Digital Audio Outputs

1 Audio Port 1 +

6 Audio Port 1 -

2 Audio Port 2 +

7 Audio Port 2 -

3 n/c

8 n/c

4 ground

9 Right Out

5 ground

Note: AES is only available for Audio 1 and 2 (Not AP)

RS232 Monitor and Control

1 DCD

6 DSR

2 RXD

7 RTS

3 TXD

8 CTS

4 DTR 

9 NC

5 GND

Alarm

6 Cue Relay 1 Com

7 Audio Port 2 +

8 n/c

13 NO Alarm Out

14 Alarm Common

Old JDAR

Relay

New i6420

Relay

Description

Relay Number

1

Top of Hour

14

2

Legal ID

13

3

Backsell Liner

2

4

Stopset Start 2 Min*

1

5

Return Liner

3

6

Image Liner

4

7

Promo Liner

5

8

Network 1

6

9

Network 2

7

10

Closed Circuit

NA

11

AP Return

11

12

Stopset Start 3 Min*

12

* Stations which carry two minutes of network inventory use relay 1
to trigger location stopset starts. Stations which carry three minutes
of network inventory use relay 12.

Notes:

Recievers are shipped with network interfaces set for

DHCP IP address assignment. Units must be

manually configured for static IP addresses.

The receiver requires either a phone line or broadband

Internet connection. Not both.

Please install receivers in a climate controlled

envioronment from 65-75 degrees.