![WestwoodOne iPump 6420 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/westwoodone/ipump-6420/ipump-6420_quickstart-installation-instructions_966423003.webp)
Station LAN
12 Foot Solid Dish
Broadband
Internet
Decoder #2 Relay Outputs
Pin Function
Pin Function
1 Relay 1
20
2 Relay 2
21 Relay
3 Relay 3
22 Common
4 Relay 4
23
5 Ground
24 Ground
6 Relay 5
25
7 Relay 6
26
8 Relay 7
27 All Relay
9 Relay 8
28 Commons
10 Ground
29 are
11 Relay 9
30 Connected
12 Relay 10
31
13 Relay 11
32
14 Relay 12
33 Ground
15 Ground
34 Relay
16 Relay 13
35 Common
17 Relay 14
36
18 Relay 15
37
19 Relay 16
Note: All Relay commons are ganged inside
the receiver. Conntact JRN if you need
isolated commons for each relay.
Decoder #1 Relay Outputs
Pin Function
Pin Function
1 Relay 1
20
2 Relay 2
21 Relay
3 Relay 3
22 Common
4 Relay 4
23
5 Ground
24 Ground
6 Relay 5
25
7 Relay 6
26
8 Relay 7
27 All Relay
9 Relay 8
28 Commons
10 Ground
29 are
11 Relay 9
30 Connected
12 Relay 10
31
13 Relay 11
32
14 Relay 12
33 Ground
15 Ground
34 Relay
16 Relay 13
35 Common
17 Relay 14
36
18 Relay 15
37
19 Relay 16
Note: All Relay commons are ganged inside
the receiver. Conntact JRN if you need
isolated commons for each relay.
Non-Dedicated Phone Line
If broadband Internet is not available.
Receiver Analog Output #1
1 Left Out (+)
6 Left Out (-)
2 Audio Ground
7 Audio Ground
3 n/c
8 n/c
4 Audio Ground
9 Right Out
5 Right Out (+)
Receiver Analog Output #2
1 Left Out (+)
6 Left Out (-)
2 Audio Ground
7 Audio Ground
3 n/c
8 n/c
4 Audio Ground
9 Right Out
5 Right Out (+)
AP News Output (if Affiliated)
1 AP 2 Min Out (+)
6 AP 2 Min Out (-)
2 Audio Ground
7 Audio Ground
3 n/c
8 n/c
4 Audio Ground
9 AP 3 Min Out (-)
5 AP 3 Min Out (+)
RBDS Data 1
2 RxD Data Out +
5 Ground
RBDS Data 2
2 RxD Data Out +
5 Ground
** Future Feature
** Future Feature
AES Digital Audio Outputs
1 Audio Port 1 +
6 Audio Port 1 -
2 Audio Port 2 +
7 Audio Port 2 -
3 n/c
8 n/c
4 ground
9 Right Out
5 ground
Note: AES is only available for Audio 1 and 2 (Not AP)
RS232 Monitor and Control
1 DCD
6 DSR
2 RXD
7 RTS
3 TXD
8 CTS
4 DTR
9 NC
5 GND
Alarm
6 Cue Relay 1 Com
7 Audio Port 2 +
8 n/c
13 NO Alarm Out
14 Alarm Common
Old JDAR
Relay
New i6420
Relay
Description
Relay Number
1
Top of Hour
14
2
Legal ID
13
3
Backsell Liner
2
4
Stopset Start 2 Min*
1
5
Return Liner
3
6
Image Liner
4
7
Promo Liner
5
8
Network 1
6
9
Network 2
7
10
Closed Circuit
NA
11
AP Return
11
12
Stopset Start 3 Min*
12
* Stations which carry two minutes of network inventory use relay 1
to trigger location stopset starts. Stations which carry three minutes
of network inventory use relay 12.
Notes:
Recievers are shipped with network interfaces set for
DHCP IP address assignment. Units must be
manually configured for static IP addresses.
The receiver requires either a phone line or broadband
Internet connection. Not both.
Please install receivers in a climate controlled
envioronment from 65-75 degrees.