background image

2

The pump has a spring loaded wave action mechanism 

installed at the bottom of the bucket. 

WORKING OF PUMP

WETTED COMPONENTS

Steel, Nitrile Rubber 

RECOMMENDED USE

With NLGI 1 & 2 Greases

Subsequent strokes of the foot lever fill the delivery hose 

& discharge begins from the pistol handle.

Pressing the foot lever 

makes a cylinder to move 

forward leaving empty 

space behind it. The 

grease due to its 

weight fills this empty 

space. 

On releasing the foot lever, 

the cylinder returns to its 

original position pushing 

the accumulated grease 

into a hollow piston that 

throws the grease from 

the pump outlet into 

delivery hose. 

Cylinder in open position

Hollow Piston

Spring Loaded Mechanism

OPERATION & USE 

1.  Fill  correct grade grease into the pump bucket.
2.  Tamp the bucket on a firm surface to push the 

grease to displace air pockets trapped in the cavities 

in the base of the bucket.

3.  Operate the pump by pressing the foot lever a few 

times until delivery commences.

4.  Now the pump is ready for dispensing. When not 

in use, the pistol handle can be put into the nozzle 

holder provided at the side of the foot lever.

Westward Operating Instructions                                                                                                                               15F220

Foot Operated Grease Pump

WARRANTY

Should this product fail to perform satisfactorily due to a defect or poor workmanship within ONE YEAR from the date of 

purchase, return it to the place of purchase and it will be replaced, free of charge. Incidental or consequential damages 

are excluded from this warranty.

LIMITED ONE - YEAR WARRANTY

Manufactured for Grainger International, Inc.
100 Grainger Pkwy., Lake Forest IL 60045 U.S.A

PRIMING THE PUMP

Priming is getting the pump started by operating foot 

lever for 3-4 minutes until grease gets dispensed 

from the the pistol handle. 

Foot operated pumps are 

difficult to prime for the first time. It takes many 

strokes to get the pump working and hence pump is 

supplied in a Pre Primed condition. Pump will have 

some grease as pre priming leaves certain amount 

of grease in the system.

When working in cold weather or using a 

thicker grease, keep grease thin for easy 

workability in one of the following ways:

•  Mix some oil (SAE30) with grease. Shake 

the bucket & press the mixture thorough-

ly to remove any air pockets

• 

Heat grease bucket with a Barrel Warmer 

or Heating Jacket. The temperature 

should be kept at 0 - 30°C (32 - 86°F)

•  Keep work area clean and remove any excess 

grease from tools, hands, and clothing after use

•  The user may need to warm grease in cold 

weather. NEVER overheat grease as it may loose 

its lubricating properties

•  This pump is not a Food Grade product

Cylinder in closed position