background image

 

 

 

    STORAGE OF VACUUM PUMPS 

 

Disconnect air lines and pump fittings from the intake and exhaust ports of the air pump.  Then open the 
flush valve and pour about  five ounces of oil into it.  Turn the rotor shaft by hand a few times to coat the 
inside of the pump housing with oil.  Close the flush valve and fill the oil tank with oil.  Plug the pump 
ports  with commercial  pipe plugs  or the plastic  plugs  that  were supplied  with the unit.   Coat the shaft 
with a small amount of grease or oil to prevent rust buildup during storage.  Store the air pump in a cool, 
dry place. 
 

IMPORTANT – 

When RE-STARTING the air pump after storage, turn the pump over by hand to be sure 

the shaft and rotor assembly spins freely within the pump housing.  If any binding or restriction is felt, the 
pump must be taken apart and cleaned. 
 
 
 
 

 

 

 

SLIDE VALVE OPERATION 

 
 

Page  3 

      

VACUUM  MODE 

PRESSURE MODE 

The Conde Slide Valve is a unique changeover valve developed by Conde Pumps to enable the 
vacuum pump to be switched from vacuum to pressure mode.  This is accomplished by simply 
pulling out the slide valve handle (vacuum mode) or pushing in the handle (pressure mode).  
The Conde Slide Valve also has a built in check valve to hold tank vacuum even when the pump 
is turned off. 

Position  Locking  Knob 
can be tightened to insure 
that handle remains in the 
proper  position  while 
pumping. 

Содержание CONDE SDS Series

Страница 1: ...OWNERS MANUAL CONDE SDS SERIES PUMPS Westmoor Ltd P O Box 99 906 West Hamilton Avenue Sherrill New York 13461 Phone 800 367 0972 Fax 315 363 0193 E mail pumps westmoorltd com S D S IMPLY ESIGNED UPER...

Страница 2: ...Close all openings in the vacuum system 3 Start pump 4 Remove plastic cover and loosen jam lock nut on top of the relief valve 5 Inside the jam nut is the adjustment screw Turn nut clockwise to increa...

Страница 3: ...to the pump the pump should be flushed im mediately to remove all contaminates If it is not immediately flushed rust can form inside the pump which can in turn cause pump failure FLUSHING INSTRUCTIONS...

Страница 4: ...NT When RE STARTING the air pump after storage turn the pump over by hand to be sure the shaft and rotor assembly spins freely within the pump housing If any binding or restriction is felt the pump mu...

Страница 5: ...the shaft collar from tool kit over shaft and tighten screw very securely Use the fan set hole to help keep the collar from sliding 6 Grease the ends of the bolts from tool kit and screw them into th...

Страница 6: ...the hex bolts and tighten securely 9 Press bearing onto shaft as previously done 10 Shim the pump as follows First of all turn rotor by hand to get a feel of how it turns when not binding on the endpl...

Страница 7: ...is closed Plumbing and or various other attachments Tighten all plumbing and anything are loose else connected to the system Motor is running too slow Adjust throttle so that the pumps are running be...

Страница 8: ...necessary Pump not receiving adequate oil Oil level in reservoir has dropped below wick Fill reservoir Vent hole on oil reservoir fill cap has plugged Clean Oil tube has come off or is leaking Reat ta...

Страница 9: ...lexible rubber spider between the pump mounted flange and the motor mounted flange Couplings must be carefully aligned per the manufacturer s speci fications A small straight edge and set of feeler ga...

Страница 10: ...the pump SECONDARY MOISTURE TRAP The secondary trap spins air to separate moisture out of the air It will also shut off the vacuum line in the event that the primary shut off fails 12 FINAL FILTER 1 S...

Страница 11: ...E REMOTE SLIDE VALVE INSTALLATIONS 7 7 EXHAUST DROP WITH DRAIN 7 EXHAUST DROP WITH DRAIN TO BE INSTALLED SO EXHAUST OIL WILL NOT DRAIN BACK TO PUMP NOTE IMPORTANT PRECAUTION WILL ENABLE TANK TO HOLD V...

Страница 12: ...HEX CAP SCREW G 4 PIN612S 1 4 X 7 8 LGTH DOWEL PIN H 16 FS19025 BEARING COVER SCREW I 2 BRC12 BEARING COVER BRS12 SET J BEARING SHIMS K 6306 HI TEMP BEARING L 2 SE0612SDS SDS SHAFT SEAL 1 4 SHAFT KEY...

Страница 13: ...M Maximum Vacuum 27 Hg intermittent Lubrication Conde Automatic Maximum Pressure 20 psig intermittent Port Size 1 1 2 Shaft Diameter 1 0 Weight Vacuum Only 87 Lbs Weight Vacuum Pressure 92 lbs ITEM Va...

Страница 14: ...MS K 6306 HI TEMP BEARING L 2 SE0612SDS SDS SHAFT SEAL 1 4 SHAFT KEY KEY06 1 3 PF215PN 2 1 8 NPT BRASS CLOSE NIPPLE O N M 3 POLY TITE ELBOW ITEM QTY PART NUMBER DESCRIPTION HS12SDS90 12 SDS VACUUM ONL...

Страница 15: ...28 Hg intermittent Lubrication Conde Automatic Maximum Pressure 20 psig intermittent Port Size 1 1 2 Shaft Diameter 1 1 8 Weight Vacuum Only 119 Lbs Conde SDS SDS 12 INLET A B C D E F G H I J K L M N...

Страница 16: ...12SDS SDS SHAFT SEAL 1 4 SHAFT KEY KEY06 1 3 PF215PN 2 1 8 NPT BRASS CLOSE NIPPLE O N M 3 POLY TITE ELBOW ITEM QTY PART NUMBER DESCRIPTION BRC12118 ULTRA VACUUM ONLY HOUSING ULTRA VAC PRESS HOUSING RT...

Страница 17: ...INLET Conde SDS INLET Conde SDS Page 16...

Страница 18: ...ENTED FILL PLUG PART NO OR212 RUBBER O RING TANK MOUNTING BOLT X4 PART NO TO016 1 4 X 040 TUBE 2 3 4 LGTH PART NO PF229 4 2 1 8 NPT X 1 4 BARB ELBOW X2 1 8 X 1 4 TUBE FEMALE ELBOW PART NO PF170P 4 2 P...

Страница 19: ...G PART NO OR212 PART NO LWSG21 2 SIGHT GLASS W O RING PART NO FSX19025 10 32 X 5 8 S S SCREW PART NO FSXW19000 10 S S SEALI NG WASHER PART NO OR231 RUBBER O RING PART NO RWPATUB025A 1 4 O D OIL TUBI N...

Страница 20: ...Page 19 C B A D E D F G EE FF H I J K L M N O P Q R S T U V W X Y Z I FSX31300 SDS SLIDE VALVE ASSEMBLY...

Страница 21: ...______________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ _...

Отзывы: