Type
Inverter heat pump
Model name
WHZ09SZA21S
WHZ12SZA21S
Power supply
208/230 V ~ 60 Hz
Available voltage range
187—253 V
Fan
Airflow rate
CFM (m
3
/h)
1,177 (2,000)
Type × Q'ty
Propeller fan × 1
Motor output
W
30
Sound pressure level *
1
dB (A)
55
Heat exchanger type
Dimensions
(H × W × D)
in (mm)
33-1/16 × 21-1/2 × 11/16 (840 × 546 × 18.19)
33-1/16 × 21-1/2 × 11/16 (840 × 546 × 18.19)
33-1/16 × 21-1/2 × 11/16 (840 × 546 × 18.19)
33-1/16 × 21-1/2 × 11/16 (840 × 546 × 18.19)
19-11/16 × 16-9/16 × 11/16 (500 × 420 × 18.19)
Fin pitch
FPI
18
Rows × Stages
2 × 26
2.5 × 26
Pipe type
Copper
Fin type
Type (Material)
Aluminum
Surface treatment
Blue fin
Compressor
Type
Rotary
Refrigerant
Type
R410A
Charge
lb oz
2 lb 7 oz
2 lb 14 oz
g
1,100
1,300
Refrigerant oil
Type
VG74 (POE)
Enclosure
Material
Steel sheet
Color
White
Dimensions
(H × W × D)
Net
in (mm)
23-1/16 × 31-7/8 × 11 (585 × 810 × 280)
Gross
25-3/16 × 37 × 15-3/16 (640 × 940 × 385)
Weight
Net
lb (kg)
75 (34)
84 (38)
Gross
82 (37)
93 (42)
Connection pipe
Size
Liquid
in (mm)
Ø1/4 (Ø6.35)
Gas
Ø3/8 (Ø9.52)
Method
Flare
Pre-charge length
ft (m)
24
.6
(7.5)
Max. length
65 (20)
Max. height difference
Indoor unit higher than outdoor unit: 32 (10)
Outdoor unit higher than indoor unit: 16 (5)
Operation range
Cooling
°F (°C)
-0.4 to 115 (-18 to 46)
Heating
-13 to 75 (-25 to 24)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB (26.67 °CDB) / 67 °FWB (19.44 °CWB), and outdoor temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB (21.11 °CDB) / 59 °FWB (15 °CWB), and outdoor temperature of 47 °FDB (8.33 °CDB) / 43 °FWB (6.11 °CWB).
– Pipe length: 24 ft 6 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
- 4 -