- 5 -
Type
Inverter heat pump
Model name
WHP09SZA21S
WHP12SZA21S
Power supply
208/230 V ~ 60 Hz
Available voltage range
198—253 V
Fan
Airflow rate
CFM (m
3
/h)
971 (1,650)
1,177 (2,000)
Type × Q'ty
Propeller fan × 1
Motor output
W
30
Sound pressure level *
1
dB (A)
53
Heat exchanger type
Dimensions
(H × W × D)
in (mm)
26-7/8 × 18-3/16 × 11/16
(683 × 462 × 18.2)
25-3/4 × 18-3/16 × 11/16
(654 × 462 × 18.2)
33-1/16 × 21-1/2 × 11/16
(840 × 546 × 18.19)
33-1/16 × 21-1/2 × 11/16
(840 × 546 × 18.19)
Fin pitch
FPI
18
Rows × Stages
2 × 22
2 × 26
Pipe type
Copper
Fin type
Type (Material)
Aluminum
Surface treatment
Blue fin
Compressor
Type
Rotary
Refrigerant
Type
R410A
Charge
lb oz
2 lb 2 oz
2 lb 9 oz
g
950
1,160
Refrigerant oil
Type
68HES-H
VG74 (POE)
Enclosure
Material
Steel sheet
Color
White
Dimensions
(H × W × D)
Net
in (mm)
19 × 28-1/8 × 9-7/16
(482 × 715 × 240)
23-1/16 × 31-7/8 × 11
(585 × 810 × 280)
Gross
20-7/8 × 33-11/16 × 13-3/8
(530 × 830 × 340)
25-3/16 × 37 × 15-3/16
(640 × 940 × 385)
Weight
Net
lb (kg)
60 (27)
73 (33)
Gross
65 (29.5)
79 (36)
Connection pipe
Size
Liquid
in (mm)
Ø 1/4 (Ø 6.35)
Gas
Ø 3/8 (Ø 9.52)
Method
Flare
Pre-charge length
ft (m)
24 (7.5)
Max. length
65 (20)
Max. height difference
Indoor unit higher than outdoor unit: 32 (10)
Outdoor unit higher than indoor unit: 16 (5)
Operation range
Cooling
°F (°C)
5 to 115 (-15 to 46)
Heating
-4 to 75 (-20 to 24)
NOTES:
•
Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB (26.67 °CDB) / 67 °FWB (19.44 °CWB), and outdoor temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB (21.11 °CDB) / 59 °FWB (15 °CWB), and outdoor temperature of 47 °FDB (8.33 °CDB) / 43 °FWB (6.11 °CWB).
– Pipe length: 24 ft 6 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
•
Protective function might work when using it outside the operation range.
•
*1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Содержание WHP09SZA21S
Страница 9: ...Installation space requirement Unit in mm 8 Provide sufficient installation space for product safety ...
Страница 11: ...Model WHP12SZA21S Unit in mm 11 280 23 1 16 585 6 5 5 7 3 0 1 8 8 7 1 3 12 3 16 310 20 1 16 510 10 ...
Страница 16: ...Refrigerant circuit Models WHP09SZA21S WHP12SZA21S WHP18SZA21S and WHP24SZA21S 15 ...
Страница 19: ...Wiring diagrams Models WHP09WMA21S WHP12WMA21S WHP18WMA21S and WHP24WMA21S 18 ...
Страница 50: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 OUTDOOR UNIT WHP24SZA21S 49 ...
Страница 53: ......