BREAK-IN PERIOD

For proper break-in, 

DO NOT

  exceed  50%  of  the  rated 

running  watts  (1800  watts)  during  the  first  five  hours  of 

operation.
Vary the load occasionally to allow stator windings to heat 

and cool and help seat the piston rings. 

BEFORE STARTING THE GENERATOR

Verify that:

•  The generator is placed in a safe, appropriate location. 
• 

The generator is on a dry, flat, and level surface.

• 

The engine is filled with oil.

•  All loads are disconnected.

Fire and explosion hazard. 

DO NOT

 move or tip the 

generator during operation.

STARTING THE ENGINE

1. 

Verify that fuel is in the gas tank. 

2. 

Turn the fuel tank valve to the ON position. 

Note: 

If cold starting, move the choke lever to the ON 

position.  

3. 

Push the Run/Stop switch to the Run position. 

4. 

Firmly grasp and pull the recoil handle slowly until you 

feel increased resistance, then pull rapidly. 

5. 

After starting, allow the engine to run for several seconds 

then move the Choke lever to the fully OFF position. 

STOPPING THE ENGINE

1. 

Turn off and unplug all connected electrical loads. 

IMPORTANT: NEVER

 start or stop the generator with 

electrical devices connected. 

2. 

Let the generator run with no load for several minutes to 

stabilize internal temperatures of the engine. 

3. 

Push the Battery switch to the OFF position. 

Note: 

Alternately, if the generator is used infrequently, turn 

the fuel tank valve to the OFF position to limit the 

residual fuel remaining in the carburetor float bowl. 

The engine will stop when fuel in the carburetor and 

fuel line is exhausted. 

4. 

If operating on propane, turn the propane tank valve to 

the fully closed position. 

FREQUENCY OF USE

If the generator will be used on an infrequent or intermittent 

basis (more than one month before next use), refer to the 

Storage section of this manual for information regarding 

fuel deterioration. 

AC CIRCUIT BREAKERS

The circuit breakers will automatically switch OFF if there 

is a short circuit or a significant overload of the generator 

at each receptacle.  
If an AC circuit breaker switches OFF automatically, 

check that the appliance is working correctly and it does 

not exceed the rated load capacity of the circuit before 

resetting the AC circuit breaker ON. 

OPERATION

Содержание WGEN3600C

Страница 1: ...MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 WGen3600c Portable Generator Gasoline 3600 Running Watts 4650 Peak...

Страница 2: ...on or design change without notice UPDATES The latest User Manual for your Westinghouse generator can be found under our support tab https westinghouseoutdoorpower com pages manuals Or scan the follow...

Страница 3: ...exposed to temperatures outside of this range during storage it should be brought back within this range before operation This product must ALWAYS be operated outdoors in a well ventilated area and fa...

Страница 4: ...ded could result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage to the gen...

Страница 5: ...ly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and elec...

Страница 6: ...ine DO NOT allow the generator s gas tank to overflow when filling Shut down the engine and allow it to cool for two minutes before adding gasoline or oil to the generator NEVER remove the fuel cap wh...

Страница 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY LABELS AND DECALS SAFETY...

Страница 8: ...attery powered carbon monoxide alarm s in your home WARNING Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator wa...

Страница 9: ...ps 4 120 Volt AC 30 Amp NEMA L5 30R Twist Lock Receptacle Receptacle can supply a maximum of 30 Amps 5 120 Volt AC 20 Amp Duplex NEMA 5 20R Receptacles Receptacles can supply a maximum of 20 Amps 6 20...

Страница 10: ...10 Westinghouse Outdoor Power Equipment LLC COMPONENTS GENERATOR COMPONENTS...

Страница 11: ...ERATOR HAS BEEN SHIPPED WITHOUT OIL DO NOT attempt to crank or start engine before it has been properly serviced with recommended oil Failure to add engine oil before starting will result in serious e...

Страница 12: ...spark or flame while fueling USING FUEL STABILIZER Adding a fuel stabilizer not included extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system Follow t...

Страница 13: ...d area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning the generator GROU...

Страница 14: ...NGINE 1 Turn off and unplug all connected electrical loads IMPORTANT NEVER start or stop the generator with electrical devices connected 2 Let the generator run with no load for several minutes to sta...

Страница 15: ...Conditioner 11 000 BTU 1010 1600 TV Tube Type 300 0 RV Refrigerator 180 600 Radio 200 0 Light 75 Watts 300 0 Coffee Maker 600 0 2590 Total Running Watts 1600 Highest Starting Watts Total Running Watt...

Страница 16: ...ol or appliance does not exceed the rated power of the generator or the receptacle being used EXTENSION CORD SIZING Only use grounded 3 prong extension cords marked for outdoor use that are rated for...

Страница 17: ...EMENT PARTS Description Part Number Air filter 5206 Oil drain plug crush washer 94007 Spark arrestor 6789 Spark plug 97108 F7TC AIR FILTER MAINTENANCE Fire hazard NEVER use gasoline or other flammable...

Страница 18: ...l used based on weather conditions Check the engine oil level before each use or every 8 hours of operation 1 Place the generator on a level surface and allow the engine to cool for several minutes 2...

Страница 19: ...e from starting 1 Place the generator on a level surface and allow the engine to cool 2 Remove the spark plug boot by firmly pulling the spark boot directly away from the engine 3 Clean the area aroun...

Страница 20: ...lames pilot lights heat and other sources of ignition such as areas with a spark producing electric motor or where power tools are operated DO NOT store the generator gasoline or propane tanks near fu...

Страница 21: ...el valve to the ON position and check for leaks Replace the fuel valve if there is any leakage VALVE CLEARANCE NOTICE Checking and adjusting valve clearance must be done when the engine is cold 1 Remo...

Страница 22: ...starts then shuts down Out of fuel Refuel Incorrect engine oil level Check engine oil level Dirty air filter Clean the air filter Contaminated fuel Drain the fuel tank Refuel with fresh gasoline Defec...

Страница 23: ...Westinghouse Outdoor Power Equipment LLC 23 EXPLODED VIEWS AND PARTS LISTS ENGINE EXPLODED VIEW EXPLODED VIEWS...

Страница 24: ...2 91359 BOLT M8X60 8 3 241704 INTAKE VALVE 8 4 245904 EXHAUST VALVE NO Code Description 8 5 241806 INTAKE VALVE SPRING LOWER SEAT 8 6 246001 VALVE SPRING 8 7 241801 INTAKE VALVE SPRING SEAT 8 8 24180...

Страница 25: ...Westinghouse Outdoor Power Equipment LLC 25 GENERATOR EXPLODED VIEW EXPLODED VIEWS...

Страница 26: ...RMAL PROTECTOR 5 2 11 96120 PAPER WASHER 5 2 12 599065 CO FLAMEOUT ACTUATOR 6 FUEL TANK 6 1 94403 FUEL LINE CLAMP 6 2 700249L 116 FUEL TANK NO Code Description 6 2 1 6516 FUEL GAUGE 6 2 2 518801 FUEL...

Страница 27: ...Westinghouse Outdoor Power Equipment LLC 27 SCHEMATICS SCHEMATICS...

Отзывы: