background image

Installation Guide  

90cm freestanding cookers

The cooker MUST be installed in compliance with:

•  Wiring connections in AS/NZS 3000 Wiring Rules.
•  Local regulations, municipal building codes and other statutory 

regulations.

For New Zealand Only:

 

The cooking range must be connected to the supply by a 
supply cord fitted with the appropriately rated plug that is 
compatible with the socket-outlet fitted to the final sub-
circuit in the fixed wiring that is intended to supply this 
cooking range.

 

Supply cord size required: 

WFE904/WFE915/WFE916 models - 2.5mm

2

  

WFEP917 models - 4.0mm

2

WFE946 models - 6.0mm

2

The Data plate gives information about rating and is located behind 
the bottom of the oven door.

•  A functional switch MUST be provided near the appliance in an 

accessible position (AS/NZS 3000 - Clause 4.7.1).

•  Wiring MUST be protected against mechanical failure (AS/NZS 

3000 - Clause 3.9).

•  Disconnection in the fixed wiring must occur in accordance with 

the AS/NZS 3000 wiring rules.

•  The cooker MUST be properly earthed.
•  This range must be connected with cable of 75°C rating minimum.
•  This product has passed the insulation resistance test after 

manufacture. If the resistance reading is low at installation, it 

is probably caused by moisture from the atmosphere being 

absorbed by the elements after the range has been produced. 
(pass at 0.01 M  AS/NZS 3000 Wiring Rules Clause 8.3.6.3).

Note: When connections are made to a multi-phase 230/240V 
supply, the bridge piece MUST be removed from between the active 
connections.

 

Rated power input 

MODEL

TOTAL KW

A1  KW

A2 KW

WFE946

13.1

3.6

9.5

TIPS & INFORMATION

 IMPORTANT

Before you cook in your new oven it is important that the protective 

oils used in the manufacture of the product be removed.

•  Make sure that the room is well ventilated (to allow smoke to 

escape).

•  Run the grill on high for 30 minutes without grill dish.
•  Then run the oven on 180°C for 1 hour.

Connecting to services and commissioning

This appliance must be installed by an authorised person, according 

to all codes and regulations of:
•  Electrical supply authorities.
•  Building regulations.

•  Local government and council authorities.

•  AS/NZS5601.1 (particular attention to 6.10.1 and figure 6.3, and 

clause 6.10.1.11).

•  AS/NZS 3000 (particular attention to clause 4.7.1  

and clause 3.9).

Securing points

Plastic clips

Plastic clip

Hard wiring detail

1.  Remove terminal cover plate from rear panel of appliance.

2.  Fit wires through hole in cover plate and make connections to 

terminals.

3.  Engage wires into plastic clip. Secure plastic clip with two long 

silver screws (supplied in separate bag).

4.  Replace cover plate onto rear panel.

GAS REQUIREMENTS

27

8

67

3

69

6

95

168

Gas connection point  

to regulator

Electrical cable  

entry point

Gas hose restraints 

point to regulator

WIRING REQUIREMENTS

6

Содержание WFE946

Страница 1: ...ind a decorative door in order to avoid overheating Due to the weight 95 100kg and size of the cooker 2 persons are required to install it Gas model clearance requirements Ensure the appliance is installed in accordance with clauses 6 2 5 and 6 10 1 1 of AS NZS 5601 1 or clauses 6 9 1 and 6 9 5 of AS NZS 5601 2 with regard to clearances to combustible surfaces and materials and clearances to range...

Страница 2: ...l position Press the locking tab down for removing the door Locking tab up at normal position Press the locking tab down for removing the door Gently close the door until it comes to a stop Then lift the door off the hinge Locking tab up at normal position Press the locking tab down for removing the door 2 Gently close the door until it comes to a stop Then lift the door off the hinge Installation...

Страница 3: ... where the anti tilt brackets need to be installed 3 After the reference line is marked pull the appliance out of the cabinet cavity to install the anti tilt brackets Anti tilt bracket installation reference line WARNING WARNING Appropriate fasteners must be used to suit the type of wall on which the anti tilt brackets are installed Freestanding unit must be pushed up against the wall on installat...

Страница 4: ...vided The stops locate into slots in the base of the appliance to prevent the product from being pulled forward when installed Measurements from the rear wall are to be adjusted if there are tiles etc that come between the appliance and the wall Once services are connected product can be lifted onto the plinth and pushed back carefully ensuring the appliance engages into both brackets at the rear ...

Страница 5: ...es are in the same orientation after installation Clip the kick panel onto the front feet of the appliance Make sure the kick panel snaps onto the larger section of the front feet Installing the trivets Install the middle trivet first by aligning the trivet with the wok burner and gently placing the trivet on hob The middle trivet is designed to guide the location of the side trivets Gently place ...

Страница 6: ...r the range has been produced pass at 0 01 M AS NZS 3000 Wiring Rules Clause 8 3 6 3 Note When connections are made to a multi phase 230 240V supply the bridge piece MUST be removed from between the active connections Rated power input MODEL TOTAL KW A1 KW A2 KW WFE946 13 1 3 6 9 5 TIPS INFORMATION IMPORTANT Before you cook in your new oven it is important that the protective oils used in the manu...

Страница 7: ...to LPG 6 Turn on the gas supply and at each new connection check for leaks using soapy water Each hotplate valve should be turned on one at a time and the injector hole blanked off for several seconds 7 The operation of the regulator can be confirmed by connecting a manometer to the pressure test point located on the side of the regulator body adjacent to the outlet With the appliance operating ch...

Страница 8: ...as If the regulator appears to not be performing satisfactorily then check the following points 1 If the outlet pressure is consistently too low then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line If this is suspected then it may be necessary to repeat th...

Отзывы: