Installation to Solid Concrete and Cinder Block

1

• When installing Westinghouse wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual con-

crete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

WARNING

Remove cord covers from wall arm assembly (

A

) as

shown in figure 1.1. Level and use wall plate as
template to mark center of holes. Drill two 1/4" (6
mm) dia. hole to a minimum depth of 2" (51 mm).
Insert anchors (

B

) in holes flush with wall as shown

in fig 1.3. Place wall mount (

A

) over anchor and

secure with wood screw (

H

) as shown in figures 1.4

and 1.6. Make sure wall mount is level, and tighten
all fasteners. See figure 1.5.

Skip to step 2 on next page.

• Concrete anchors are 

not 

intended for attachment to

concrete wall covered with a layer of plaster, drywall,
or other finishing material as shown below. If mounting
to concrete wall covered with plaster/drywall is
unavoidable, plaster/drywall (up to 5/8" thick) must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than
5/8", custom fasteners must be supplied by installer.

WARNING

B

concrete
wall

B

Drill holes
and insert
anchors.

Place wall
plate over
anchor and
secure with
screw.

Tighten all
fasteners.

H

WALL PLATE

fig. 1.3

fig. 1.4

fig. 1.5

CUT

A

W

A

Y

 VIEW

CORRECT

concrete

plaster/
dry wall

INCORRECT

concrete

plaster/
dry wall

A

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

WARNING

A

H

B

A

fig. 1.6

WALL PLATE

Содержание MT80 ARM20

Страница 1: ...tures Universal design for 20 42 flat panel screens Three tensionable pivot points for extensive adjustment of viewing angle VESA 100 200 200 x 200 compatible Frees up space by folding flat against th...

Страница 2: ...good mechanical aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the eq...

Страница 3: ...3 16 allen wrench 1 560 9713 E M4 x 7 x 12 mm phillips screw 4 504 2013 F M4 x 7 x 20 mm phillips screw 4 504 2014 G M6 x 1 x 12 mm phillips screw 4 520 2039 H 14 x 2 1 2 flat head wood screw 2 520 2...

Страница 4: ...4 mm dia holes 2 5 65 mm deep Attach wall mount A to wall using two 14 x 2 5 flat head wood screws H as shown in figure 1 2 Skip to step 2 on page 6 1 Makesurethatthewallwillsafelysupportthecombinedl...

Страница 5: ...le to a minimum depth of 2 51 mm Insert anchors B in holes flush with wall as shown in fig 1 3 Place wall mount A over anchor and secure with wood screw H as shown in figures 1 4 and 1 6 Make sure wal...

Страница 6: ...crews using security allen wrench D For additional screen compatibility please refer to the Westinghouse D cor wall mount list on out website at www westinghousedigital com 2 If screws don t get three...

Страница 7: ...ate to back of screen using four M4 x 20 mm screws F as indicated in figure 2 5 FOR VESA 200 x 200 MOUNTING PATTERN Thread two M6 x 12 mm screws G leaving 25 exposed thread into top holes on back of s...

Страница 8: ...with excessive force Overtightening can cause damage to mount Tighten screws to 40 in lb 4 5 N M maximum torque CAUTION TENSIONKNOB Note Make sure cords have enough slack to allow full movement of th...

Страница 9: ...crease tension turn tension screw s clockwise with 3 16 allen wrench D To reduce tension turn tension screw s counter clockwise with allen wrench Do not turn more than half a turn 5 TENSIONSCREWS Do n...

Страница 10: ...damage caused by a service or repairs by anyone other than personnel authorized by Westinghouse Digital Electronics b the failure to utilize proper packing when returning the product c improper instal...

Отзывы: