Westinghouse iGen1200 Скачать руководство пользователя страница 24

24 | Westinghouse Portable Power

WARNING

Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner’s 

manual and understand and follow all safety instructions. Failure to follow all instructions may result in conditions that 

can lead to voiding of the EPA certification or product warranty, serious personal injury, property damage or even death.

TROUBLESHOOTING 

PROBLEM

POTENTIAL CAUSE

SOLUTION

Engine is running, but no 

electrical output.

1. Reset breaker is tripped.

1. Reset the reset breaker (see page 16).

2. The power cord’s plug connector is not fully 

engaged in the inverter’s outlet.

2. Verify plug connector is firmly engaged 

in the inverter’s outlet.

3. Faulty or defective power cord

3. Replace power cord.

4. Faulty or defective electrical appliance

4. Try connecting a known good appliance 

to verify the inverter is producing electrical 

power.

Engine will not start or remain 

running while trying to start.

1. Inverter is out of gasoline.

1. Add gasoline to the inverter (see page 

14).

2. Fuel flow is obstructed.

2. Inspect and clean fuel delivery passages.

3. Dirty air filter

3. Check and clean the air filter (see page 

19).

4. Low oil level shutdown switch is preventing 

the unit from starting.

4. Check oil level and add oil if necessary 

(see page 18).

5. Spark plug boot is not fully engaged with 

the spark plug tip.

5. Firmly push down on the spark plug boot 

to ensure the boot is fully engaged.

6. Spark plug is faulty.

6. Remove and check the spark plug. 

Replace if faulty (see pages 21).

7. Dirty/plugged spark arrestor

7. Check and clean the spark arrestor (see 

page 22).

8. Stale fuel

8. Drain fuel and replace with fresh fuel.

Inverter suddenly

stops running.

1. Inverter is out of fuel.

1. Check fuel level (see page 14). Add fuel 

if necessary.

2. The low oil shut down switch has stopped 

the engine.

2. Check oil level and add oil if necessary 

(see page 18).

3. Too much load

3. Restart the inverter and reduce the load.

Engine runs

erratic; does not hold a

steady RPM.

1. Choke was left in the CHOKE position.

1. Move choke to the RUN position

2. Dirty air filter

2. Clean the air filter (see page 19).

3. Applied loads maybe cycling on and off

3. As applied loads cycle, changes in 

engine speed may occur; this is a normal 

condition.

Содержание iGen1200

Страница 1: ...USER MANUAL iGen1200 Digital Inverter Generator 1000 Running Watts 1200 Peak Watts FOR MODELS...

Страница 2: ...tructions and precautions can cause you and others to be seriously hurt or killed Model Number Running Watts Peak Watts Fuel Tank Size L G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Strok...

Страница 3: ...TINGHOUSE PRODUCT REGISTRATION FORM PERSONAL INFORMATION INVERTER INFORMATION First Name ________________________________________ Model Number ______________________________________ Last Name ________...

Страница 4: ...11 Power Output and Demand 12 Initial Oil Fill 13 Adding Checking Engine Fluids and Fuel 14 Checking and or Adding Engine Oil 14 Adding Gasoline to the Fuel Tank 14 Starting iGen1200 15 Stopping the I...

Страница 5: ...ot avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause da...

Страница 6: ...ever remove the fuel cap with the engine running Never refuel the inverter while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank with...

Страница 7: ...sonal injury UNPACKING Tools required box cutter or similar device 1 Carefully cut the packing tape on top of the carton 2 Remove socket wrench oil and funnel and save for later 3 Carefully cut two si...

Страница 8: ...il Handle Pull to start the engine Engine Control Switch Turns the fuel on and off 1 5 6 7 8 9 2 3 4 2 1 3 4 5 6 7 8 9 Engine Service Panel Remove the panel to access the engine and oil for maintenanc...

Страница 9: ...uce the load Push in the reset breaker to reset it Efficiency Mode Switch When turned to the ON position the engine will sense the load needed and run at a slower RPM to save fuel 1 2 3 4 5 6 7 8 9 Gr...

Страница 10: ...more often during the first couple times of operating the generator NOTICE Weather will affect engine oil performance Change the type of engine oil used based on weather conditions to suit the engine...

Страница 11: ...d on other manufacturers inverters Always ensure that both ends of the paralleling cord are switched off before connecting the inverters INVERTER PARALLELING OPERATION 1 Using only the Westinghouse pa...

Страница 12: ...to estimate it A rule of thumb for devices fitted with an electric motor is to apply a starting power multiplier of 1 2 for small hand held or portable devices and a value of 3 5 for larger stationar...

Страница 13: ...ING ENGINE OIL REVIEW SAFETY SECTION STARTING ON PAGE 5 NOTICE Engine oil must be added when the inverter is on a flat level surface or an inaccurate reading may result Do not overfill If the engine i...

Страница 14: ...engine oil will permanently damage internal engine components The engine is equipped with a low oil shutdown switch If the oil level becomes low the engine may shut down and not start until the oil i...

Страница 15: ...l circuit Never operate the inverter in an enclosed area Engine exhaust contains carbon monoxide Only operate the inverter outside and away from windows doors and vents Starting the iGen1200 Be sure t...

Страница 16: ...ments Efficiency mode should be used only after the inverter has been warmed up to operating temperature 1 To turn on the efficiency mode press the switch to the ON position 2 If no load is present th...

Страница 17: ...the touch prior to performing any maintenance procedure Internal pressure can build in the engine crankcase while the engine is running Removing the oil fill plug dipstick while the engine is hot can...

Страница 18: ...e oil as specified in Figure 13 8 Using the supplied oil funnel slowly add engine oil to the engine Stop frequently to check the oil level and avoid overfilling 9 Continue to add oil until the oil is...

Страница 19: ...e of used engine oil by dumping the oil into a sewer on the ground or into groundwater or waterways Always be environmentally responsible Follow the guidelines of the EPA or other governmental agencie...

Страница 20: ...air filter element by again applying a slow firm squeezing action 9 Return the air filter element to its position in the air cleaner housing 10 Install the air cleaner cover making sure the tabs lock...

Страница 21: ...e Figure 21 Figure 21 Remove spark plug with socket wrench MAINTENANCE 7 Place a clean rag over the opening created by the removal of the spark plug to make sure no dirt can get into the combustion ch...

Страница 22: ...ain the correct valve lash When the valve lash is correct hold the adjusting nut and tighten the jam nut to 106 in lb 12 N m 8 Recheck the valve lash after tightening the jam nut 9 Perform this proced...

Страница 23: ...ylinder wall from corroding during storage 7 Replace the spark plug see Spark Plug Maintenance on page 21 8 Move the inverter to a clean dry place for storage CLEANING THE INVERTER It is important to...

Страница 24: ...er see page 14 2 Fuel flow is obstructed 2 Inspect and clean fuel delivery passages 3 Dirty air filter 3 Check and clean the air filter see page 19 4 Low oil level shutdown switch is preventing the un...

Страница 25: ...or Main winding R R R W W W Bl Bl Bl R R Y G Bl R Y Bu Bl R Bl W P Bl Bl Bl Bu W Br Gr Br R Generator Engine AC pilot light Overload indicator light Oil warning light Control Panel Reset Bl W Bl W DC...

Страница 26: ...26 Westinghouse Portable Power iGen1200 EXPLODED VIEW...

Страница 27: ...E 29 FUEL HOSE 30 CLIP FUEL LINE 9 5 31 CLIP FUEL LINE 11X0 8 32 FUEL PUMP 33 SELF TAPPING SCREW M5X16 34 100526 PANEL LEFT NO PART DESCRIPTION 35 150524 OIL DRAIN 36 150523 FUEL TANK CAP SOMP 37 1505...

Страница 28: ...28 Westinghouse Portable Power iGen1200 ENGINE VIEW NOTE Parts with no number are not stocked by the manufcturer Please call our service team if you have questions...

Страница 29: ...TOR 35 BOLT M5 25 36 STATOR 37 BOLT STUD 38 THE TRIGGER 39 CLIP BOLT 40 100592 CLIP FUEL LINE 41 BOLT STUD 42 SEAT CRANKCASE 43 OIL SEAL NO PART DESCRIPTION 44 TUBE FUEL INLET 45 SWITCH ASSEMBLY OIL L...

Страница 30: ...lastic Fuel Tank Capacity Gallons Liters 8 gal 3 L Run Time at 25 Load hrs 9 hrs Run Time at 50 Load hrs 7 hrs Gasoline Fuel Gauge No Choke type Manual Choke Location Side Panel AC Outlets 1 Duplex 12...

Страница 31: ...Westinghouse Portable Power 31 Version 6 15 18KD...

Отзывы: