![Westinghouse GHP16 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/westinghouse/ghp16/ghp16_installation-manual_964417007.webp)
DIMENSION AND INSTALLATION GUIDE
PHL222
320mm
505mm
40mm
(built-in height)
600mm
303mm
485mm
50mm min
©
2008 Electrolux Home Products Pty Ltd
WDIMPHP222 Current as at Jul 2008
Note:
Connection type – hardwired
Maximum power load 3.0kW
Note:
Any walls surrounding the cooktop are to be heat resistant up to 90
o
C,
up to 150mm high eg. ceramic tiles.
Note:
If a barrier is not required, a minimum gap of 30mm is needed under
the cooktop.
Note:
If the base of the cooktop can be touched from inside a cupboard or
drawer, a barrier MUST be installed to prevent contact. The material for
the barrier must be capable of sustaining heat up to 70
o
C. Make sure
the barrier is at least 50mm and not more than 75mm below the base
of the cooktop. The barrier is to have ventilation holes evenly spaced
in the one of the following configurations: 25 x 25mm diameter,
15 x 35mm diameter or 6 x 50mm diameter.
cooktop dimensions
building-in cut-out dimensions
electric ceramic cooktop
MODEL:
PHP222