TROUBLESHOOTING 

PROBLEM

POTENTIAL CAUSE

SOLUTION

Generator suddenly

stops running.

1. Generator is out of fuel.

1. Check fuel level. Add fuel if necessary.

2. The low oil shut down switch has 

stopped the engine.

2. Check oil level and add oil if 

necessary.

3. Too much load

3. Restart the generator and reduce the 

load.

4. If trying 1-3 above does not solve the 

problem,the cause might be a fault in the 

generator.

4. Take the generator to your nearest 

authorized service dealer.

Engine runs

erratic; does not hold a

steady RPM.

1. Dirty air filter

1. Clean the air filter.

2. Applied loads maybe cycling on and 

off

2. As applied loads cycle, changes in 

engine speed may occur; this is a normal 

condition.

3. If trying 1-3 above does not solve

the problem, the cause might be a

fault in the generator

3. Take the generator to your nearest 

authorized service dealer.

Содержание Gen9500

Страница 1: ...USER MANUAL WGen9500 Portable Generator 9500 Running Watts 12500 Peak Watts REMOTE START...

Страница 2: ...to be seriously hurt or killed Model Number Running Watts Peak Watts Fuel Tank Size L G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity L Oil Type THD WGen9500 9500...

Страница 3: ..._________________________ Model Number ______________________________________ Last Name ________________________________________ Serial Number _______________________________________ Street Address __...

Страница 4: ...e Fuel Tank 18 How to Pair Remote Key Fob 19 Power Output and Demand 19 Starting the Generator 20 Electric Start 20 Manual Start 21 Stopping the Generator 21 Normal Operation 21 During an Emergency 21...

Страница 5: ...ot avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause da...

Страница 6: ...Never remove the fuel cap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank wit...

Страница 7: ...3 4 2 Made in China Fabriqu en Chine MWE Investments LLC Columbus Ohio 43228 USA Con u columbus Ohio tats Unis MWE Investments LLC Columbus Ohio 43228 Etats Unis Part N0 Num ro de pi c e Designed in C...

Страница 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 9 7 10 8 9 6 6 7 5 10...

Страница 9: ...heel Kit Accessories cardboard box 3 Carefully cut two sides of the carton to remove the generator WHAT COMES IN THE BOX Manual Quick Start Guide Maintenance Schedule Wireless Remote Starter 1 1 1 Lit...

Страница 10: ...wheel kit is not intended for on road use The wheel kit is designed for use on this generator only INSTALLING FEET TO FRAME 1 Place generator on a flat surface 2 Place a piece of cardboard or other s...

Страница 11: ...iver remove the screw on the red positive battery lead 2 Securely tighten the positive battery cable red boot to the positive battery post Make sure boot is over battery post ASSEMBLY 3 Locate the bla...

Страница 12: ...tric start models Oil Fill Plug Dipstick Must be removed to add and check oil Oil Drain Plug Must be removed to drain engine oil FEATURES Never Flat Wheels For easy portability Fuel Shut off Valve Con...

Страница 13: ...r models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sparks from exiting the muffler It must be removed for servicing...

Страница 14: ...rminal The ground terminal is used to ground the generator Push Button Electric Start Push for 1 second to automatically start the engine Push again to stop the engine Engine Control Switch Battery Di...

Страница 15: ...utput will be reduced approximately 3 5 for every 1000ft of increased altitude from sea level This is a natural occurrence and cannot be adjusted by engine Increased exhaust emissions can also result...

Страница 16: ...on the top line of the chart Then select the rated amperage of the generator on the left side of the chart Where the two meet is the size of the conductor required for the application When using the W...

Страница 17: ...aintained during the operation of the generator Failure to maintain the proper oil level can result in engine damage OPERATION CONNECTING THE GENERATOR TO A BUILDING ELECTRICAL SYSTEM It is recommende...

Страница 18: ...ify the following The engine is filled with engine oil See Checking Engine Oil The generator is situated in a proper location Location Selection The generator is on a dry surface Weather and Dry Surfa...

Страница 19: ...e running power demand again but for the largest motor driven device use the value of its starting power demand instead of its running power demand This total must not be greater than the generator s...

Страница 20: ...then hold down START on the remote key fob until the generator starts then release see Figure 11 START STOP Figure 11 Push Button Start Remote Start The engine will automatically set the choke and be...

Страница 21: ...Figure 12 Pull recoil 7 Plug in electric devices STOPPING THE GENERATOR Normal Operation During normal operation use the following steps to stop your generator 1 Remove any connected loads from the co...

Страница 22: ...tor to malfunction and could result in death or serious injury NOTICE Periodic maintenance intervals vary depending on generator operating conditions Operating the generator under severe conditions su...

Страница 23: ...muffler cover 4 Once the cover is removed locate the screw on the tip of the muffler and remove Pull the spark arrestor out of the muffler see Figure 15 Figure 15 Remove spark arrestor 5 If the spark...

Страница 24: ...Figure 18 below Figure 18 Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick and wipe it clean Thread the oil fill plug dipstick all the way back i...

Страница 25: ...Only apply slow but firm squeezing action 6 Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action CHANGING ENGINE OIL 1 Always operate or maint...

Страница 26: ...ug boot by firmly pulling the plastic spark plug boot handle directly away from the engine see Figure 23 NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug...

Страница 27: ...nths and run for a minimum of 15 minutes or a charger should be plugged into the generator and the generator should be charged overnight Make sure the engine control switch is in the STOP position whe...

Страница 28: ...r to remove dirt and debris stuck in the cooling air inlets and exhaust ports General Cleaning of the Generator Use a damp rag to clean all remaining surfaces STORING GENERATOR WARNING Never store a g...

Страница 29: ...tton on the GFCI outlet 6 If trying 1 5 above does not solve the problem the cause might be the generator has a fault 6 Take the generator to your nearest authorized service dealer Engine will not sta...

Страница 30: ...load 4 If trying 1 3 above does not solve the problem the cause might be a fault in the generator 4 Take the generator to your nearest authorized service dealer Engine runs erratic does not hold a ste...

Страница 31: ...Westinghouse Portable Power 31 WGen9500 SCHEMATIC...

Страница 32: ...order 210004 GENERATOR COVER 210003 WGC25 25 POWER CORD 210052 30A 6 BREAKER TRANSFER SWITCH KIT MODEL WHMTS30 210075 25 CORD 30AMP TRANSFER SWITCH 210076 50A 6 BREAKER TRANSFER SWITCH KIT MODEL WHMTS...

Страница 33: ...ODED VIEW PART NO No Part DESCRIPTION 1 300654 FRAME 2 100552 ISOLATOR B 3 100558 BATTERY HOLDER 4 100551 NUT M10 5 180524 NUT M8 6 150507 CONNECTING PIPE 7 180563 BRACKET AIR CLEANER 8 120505 BOLT M6...

Страница 34: ...660 CRANKCASE 2 180593 BALL BEARING 3 180504 OIL SEAL 4 180411 SEAL GOVERNOR ARM SHAFT 5 180410 SHAFT GOVERNOR ARM 6 190409 WASHER GOVERNOR ARM SHAFT 7 190408 PIN LOCK 8 180507 BOLT DRAIN PLUG 9 18050...

Страница 35: ...217 STEPPER MOTOR 140548 HIGH ALTITUDE CARBURETOR ASSY SOLD SEPARATE m07500 MAINTENANCE KIT SOLD SEPARATE 170040 STARTING SOLENOID 300504 SPARK ARRESTOR WGen9500 ENGINE VIEW PART NO NO PART DESCRIPTIO...

Страница 36: ...es 1 1 qt 37 2 oz Low Oil Shutdown Automatic Fuel Type Unleaded Gasoline 10 Ethanol or less Fuel Shut Off Manual Fuel Tank Material Steel Fuel Tank Capacity Gallons Liters 6 6 gal 25 L Run Time at 25...

Страница 37: ...stinghouse Portable Power 37 Version 10 25 18KD Service Hotline 855 944 3571 777 Manor Park Drive Columbus OH 43228 TM 2019 Westinghouse Electric Corporation 2019 MWE Investments LLC All Rights Reserv...

Отзывы: