Westinghouse 77885 Скачать руководство пользователя страница 1

BLUE

AZUL

BLEU

BLUE

AZUL

BLEU

BLUE (FOR LIGHT)

AZUL (PARA LA LUZ)

BLEU (POUR LAMPE)

AC 120V           INPUT

BLACK

NEGRO

NOIR

BLACK

NEGRO

NOIR

BLACK

NEGRO

NOIR

BLACK

NEGRO

NOIR

WHITE

BLANCO

BLANC

GREEN TO GROUND

VERDE A TIERRA

VERT DE MISE À LA TERRE

FAN

VENTILADOR

VENTILATEUR

GREEN TO GROUND

VERDE A TIERRA

VERT DE MISE À LA TERRE

BLACK (AC IN L) 

NEGRO (ENTRADA CA L)

NOIR (AC DANS L)

BLACK (TO MOTOR L) 

NEGRO 

(

AL MOTOR L)

NOIR (à MOTEUR L)

6-32 x 1-1/8" SCREWS

TORNILLOS DE 6-32 x 1-1/8"

VIS 6-32 x 1-1/8"

77885

77885

Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com

 

       and Westingouse are trademarks of Westinghouse Electric Corporation.                                  Used under license by Westinghouse Lighting.                                  All Rights Reserved.                                   Made in China 

SAFETY PRECAUTIONS:

WARNINGS: 

•  To avoid fire, shock, and serious personal injury, follow all instructions 

carefully. Read and save these instructions for future reference.

•  Do not install or use this unit if any part is damaged or missing.
•  WARNING! To reduce the risk of fire or electric shock, do not use it with 

any additional solid state fan speed control device, or any additional 
variable speed control.

NOTICE:

1.  This control is designed to operate only one ceiling fan and accessory light kit. 
2.  This wall control is rated for a maximum (ceiling fan only) of 1.0 motor amp at 120 

volts, and total lamp wattage equaling 80 Watt maximum. 

3.  Make sure no bare wires are exposed outside of the connectors.
4.  All wiring must conform to National and Local Electrical Codes. If you feel 

that you do not have enough electrical wiring knowledge or experience, have 
your fan control installed by a licensed electrician. 

Any electrical work not 

described in this manual should be performed by a licensed electri-
cian.

5. Use of this control with some ceiling fans could result in fire, shock, 

and serious personal injury. Use this fan control only with capacitor 
speed controlled ceiling fans only.

Installation & Operating Instructions for the 

Westinghouse Ceiling Fan/Light Wall Control 

WARNING: SHUT POWER OFF AT 

FUSE OR CIRCUIT BREAKER

MAKING THE ELECTRICAL CONNECTIONS:

NOTE: Installation of this control requires that the three-conductor cable with 
ground wire be run between the control wall box and the ceiling fan outlet.

1.  If your ceiling fan is equipped with variable speed and light ON/OFF pull 

chain switch controls, make sure to set the speed control at the highest 
speed and the light to the ON position before installing the wall control. This 
will avoid erratic speeds and possible damage to your ceiling fan.

2.  Verify proper operation of the ceiling fan wall control before installation. 

Improper wiring can damage the control and will void the warranty.

3.  Disconnect power to the ceiling fan at the main electric panel. Remove the 

fuse or switch the circuit breaker to the OFF position.

4. Remove the wallplate to expose the wiring and disconnect the existing 

switch. Install the control in a metal or plastic wall box.

5.  Make electrical connections as follows:

• Connect the black wire marked with "TO MOTOR L" from the wall 

control to the BLACK wire from the fan. 

•  Connect the BLUE wire from the wall control to the RED or BLUE wire 

from the fan. 

•  Connect the black wire marked with "AC IN L" from the wall control to 

the 120v AC HOT wire. 

•  Use the wire connectors provided to secure the connections. 
• Connect the GREEN/Ground wire from wall control to the grounding 

wire from wall box.

NOTE: Refer to the diagram on the back of the wall control.

1.  Secure the wall control to the wall box using the two 6-32” x 1-1/8” screws provided.
2.  Press the wallplate onto the wall control with an appropriate force. 
3.  Restore power at main electrical panel. 
4.  Operate ceiling fan and light by pressing the fan speed / light buttons to desired 

speed / light level. 

WARNING! HOOK UP “IN SERIES” ONLY!

Do not connect to hot and neutral wire of electric circuit or switch will 
be damaged. Refer to diagram above.

TROUBLESHOOTING GUIDE

PROBLEM: WALL CONTROL FAILS TO OPERATE
Check: 

•  Is there power to the control unit?
•  Is the control unit wired correctly?
•  Are the fan and light switches set on the highest position?

LIMITED WARRANTY

  The Westinghouse universal ceiling fan/light wall control offers a limited war-
ranty of one year from the date of purchase to the original owner against defects 
in material and workmanship. All spare parts are covered for ninety days only. This 
warranty is in lieu of all other warranties expressed or implied.
  Westinghouse will repair or replace this universal ceiling fan/light wall control if 
it is defective due to faulty materials or workmanship. This warranty does not cover 
service charges, defects resulting from accidents, damages caused through abuse 
or alterations or by affixing any attachment not provided with the product, improper 
installation or maintenance, failure of supporting devices not supplied as original 
mounting hardware, exposures to extremes of heat or humidity, incorrect voltage, 
surges in current, unauthorized repair, or failures caused by modifications of the 
product or the acts of third parties. See remote manual for proper installation.
  If this product fails for any reason covered by this warranty, please contact 

us at www.westinghouselighting.com/contact-us.

SET button

 (under the small wallplate):

The SET button is recessed into the hole, 
use a hard, slender object, such as a needle, 
to insert into the SET hole. It is for setting 
suitable dimmer level. 
1. When the light flickers after dimming, 
    you can use this button to improve this     
    as following:
    Turn on the fan light and dim light to 
    a suitable level, then short-press the SET 
    button, the light will turn off and back on,  
    it means the new dimmer level is activated 
    and memorized. 
2. Press and hold the SET button for 3 
    seconds to clear the memorized dimmer 
    level. The light will turn off and back on,  
    it returns to the default dimmer level.

HOW TO OPERATE YOUR WALL CONTROL:

The remote buttons function as follows:
(1) Fan speed:
              = High speed
              = Medium-high speed
              = Medium Speed
              = Low Speed
(2)          Button: Turn the fan off
(3)          - Light On/Off  - press and release light button.
              - Light Dimmer - continuously press the light 
                button to brighten the light
               - Light Dimmer - continuously press the light 
                button to dim the light. 

            

   Power off switch- Carefully take off the wallplate 

              and pull out this switch for cutting off the AC power.
              

Note: This switch to designed to disconnect the power if the 

            ceiling fan is not used for a long time.

Power Off Switch

Wallplate

Small Wallplate

Instrucciones de instalación y funcionamiento para 

el control de pared para ventilador de techo/juego 

de luz Westinghouse

¡ADVERTENCIA! DESCONECTE 

EL SUMINISTRO ELÉCTRICO 

QUITANDO EL FUSIBLE O 

APAGANDO EL CORTACIRCUITO.

PRECAUCIONES DE  SEGURIDAD:

ADVERTENCIAS: 

•  Para evitar incendios, descargas eléctricas y heridas personales graves, 

siga todas las instrucciones con cuidado. Lea y guarde estas instruc-
ciones para referencia futura.

•  No instale ni utilice esta unidad si alguna pieza está dañada o falta.
• ¡ADVERTENCIA! Para reducir el riesgo de incendio o descarga eléc-

trica, no lo use con cualquier dispositivo de control de velocidad de 
ventilador de estado sólido adicional, o cualquier control de velocidad 
variable.

AVISO:

1.  Este control está diseñado para operar solo un ventilador de techo y un 

juego de luces auxiliares.

2.  Este control de pared está clasificado para un máximo (solo ventilador de 

techo) de 1,0 amperios de motor a 120 voltios y un vataje total de la lámpara 
de 80 vatios como máximo.

3.  Asegúrese de que no queden cables desnudos fuera de los conectores.
4. Todo el cableado debe cumplir con los códigos eléctricos nacionales y 

locales. Si tu sientes que no tiene suficiente conocimiento o experiencia en 
cableado eléctrico, tenga su control de ventilador instalado por un electricista 
calificado. 

Cualquier trabajo eléctrico no descrito en este manual 

debe ser realizado por un electricista calificado.

5. El uso de este control con algunos ventiladores de techo podría provo-

car incendios, descargas eléctricas y heridas personales graves. Use 
este control de ventilador solo con ventiladores de techo controlados 
solo por capacitor de velocidad.

REALIZACIÓN DE LAS CONEXIONES 

ELÉCTRICAS:

NOTA: La instalación de este control requiere que el cable de tres   
conductores con cable a tierra entre la caja de pared de control y 
la salida del ventilador de techo.

1.  Si su ventilador de techo está equipado con tirador de cadenilla para 

velocidad variable y  controles de luz ENCENDIDO/APAGADO, asegúrese 
de establecer el control de velocidad variable en la posición de velocidad 
más alta y la luz en la posición ON (encendido) antes de instalar el control 
de pared. Esto evitará velocidades erráticas y posibles daños a su ventila-
dor de techo.

2.  erifique que el control de pared del ventilador de techo funcione correct-

amente antes de la instalación. El cableado inadecuado puede dañar el 
control y anulará la garantía.

3.  Desconecte la alimentación del ventilador de techo en el panel eléctrico 

principal. Quitale el fusible o cambie el corta circuito (disyuntor) a la posición 
APAGADO.

4. Retire la placa de pared para exponer el cableado y desconecte el exis-

tente. Instale el control en una caja electrica de metal o plástico.

5.  Realice las conexiones eléctricas de la siguiente manera:

•  Conecte el cable negro marcado con "TO MOTOR L" del control de 

pared al cable NEGRO del ventilador.

•  Conecte el cable AZUL del control de pared al cable ROJO o AZUL del ventilador. 
•  Conecte el cable negro marcado con "AC IN L" del control de pared 

al el cable VIVO de CA de 120 V.

•  Utilice los conectores de cables provistos para asegurar las conexiones.
• Conecte el cable verde del control de pared al cable de conexión 

puesto a tierra de la caja de pared.

   NOTA: Consulte el diagrama en la parte posterior del control de 

pared.

1.  segure el control de pared a la caja electrica usando los dos tornillos de 

6-32” x 1-1/8” provistos. 

2.  Presione la placa de pared contra el control de pared con fuerza adecua-

da.

3.  Restaure la energía en el panel eléctrico principal.
4.  Opere el ventilador de techo y la luz presionando los botones de luz/velocidad del 

ventilador al nivel deseado.