Warranty

ONE YEAR LIMITED WARRANTY

A thorough inspection must be made before installation and any damage must be promptly reported . We will not be liable for failures or 
damage that could have been discovered or avoided by proper inspection and testing prior to installation .

Conglom Kitchen & Bath warrants this product to be free from defects in materials or workmanship for one (1) year from the date of purchase . 
Proof of purchase (original sales receipt) from the original consumer purchaser must be made available to Conglom Kitchen & Bath for all 
warranty claims .  

This warranty is non-transferable and shall be voided if the unit is removed from its initial installation or if it is not installed following the 

manufacturer’s instructions . It does not apply in the event of product damage due to the use of other than genuine Conglom Kitchen & 

Bath  replacement  parts,  (Replacement  parts  may  be  obtained  by  e-mail  at  [email protected]  or  by  calling  1-877-333-0098  between

 

8:30 am - 5:00 pm EST) installation error, abuse, misuse or improper care and maintenance (whether performed by a plumber, contractor, 

service provider or member of the purchaser’s household) . The warranty excludes damage due to aggressive air or water conditions, harsh 
or abrasive cleaners and/or materials . 

Under no circumstance shall we be held liable for personal injury or property damage resulting from improper installation or use of this 
product . We will not be held liable for inconvenience caused by loss of use of this product, costs incurred for labour or materials, removal 
and installation of replacement units, or any other incidental or consequential damages . Costs relating to obtaining access for repair or 
replacement are the responsibility of the user . 

Our obligation shall be limited to the repair or replacement of a unit (at our discretion) that may prove, by our sole examination, to be defective 
under normal use and service during the warranty period . 

Any failure of this product that is not traceable to a defect in material or workmanship is not covered by this warranty. These non-warrantable 
items include, but are not limited to: 

 

-

Improper installation not in accordance with manufacturer’s instructions .

 

-

Dents and/or scratches incurred during shipping, handling, or installation . 

 

- Change in colour or finish due to chemical usage.

 

-

Damage caused by failure to follow care and cleaning guidelines, including damage caused by the use of abrasive cleaners .

 

-

Alterations made to the unit by the purchaser or installer .

 

- Damage caused by accidental impact, fire, flood, freezing, and normal wear.

 

- Bends and warping caused by forced connections, over-tightened fittings, and inadequate support during installation.

 

-

Any defects or damage to light bulbs .

This warranty does not extend to commercial and institutional installation or use .

WARRANTY CLAIM PROCEDURE

If  a  claimable  defect  occurs  or  replacement  parts  are  needed,  please  contact  our  customer  service  team  at  [email protected]  or

 

1-877-333-0098 (Service available in English and French, Monday - Friday from 8:30 am - 5 pm, EST).

Before you make your call, please ensure that you have:

 

-

Model number or description .

 

-

Proof of sale .

 

-

Details regarding the defect and/or part number . 

 

-

Name(s) and address(es) of the owner and/or installer .

Содержание 457-8612

Страница 1: ...QR090 457 8612 QR091 457 8613 QR102 457 8614 OWNER S MANUAL UNDER CABINET RANGE HOOD...

Страница 2: ...ideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the l...

Страница 3: ...d burns Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flamin...

Страница 4: ...labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility...

Страница 5: ...r further assistance Pre Installation TOOLS MATERIALS REQUIRED NOT SUPPLIED Measuring tape Level Utility knife Pencil Certified Duct Tape Adjustable wrench Phillips screwdriver Flathead screwdriver Ne...

Страница 6: ...coal filters 2 C Rectangular damper located inside the hood 1 D Round adapter located inside the hood 1 HARDWARE INCLUDED NOTE Parts not shown in actual size AA BB CC DD Part Description Quantity AA L...

Страница 7: ...sized wood filler strips 4 on each side using wood screws 3 Screws are provided to secure the range hood to most types of cabinets but consult a qualified installer to verify that the supplied screws...

Страница 8: ...nce and use no more than three 90 elbows Ensure that there is a minimum of 458 mm 18 in of straight vent between each elbow Elbow as far away from the range hood s exhaust opening as possible Cap the...

Страница 9: ...A hole cut through wood must be sanded until smooth A hole through metal must have a grommet 10 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden util...

Страница 10: ...crews holding cover 6 in place and remove the cover as per Fig 12 DO NOT REMOVE ANY OTHER VENTING HOLE COVER INSTALLING THE DAMPER SKIP THIS STEP IF YOU ARE USING INTERIOR VENTING E Fig 14 NOTE Only i...

Страница 11: ...n the screws all the way leave the screw heads about 7 mm 0 28 in from the cabinet surface Lift the range hood A into position feeding the power cable and the electrical wires through the power access...

Страница 12: ...OR VENTING NOTE The charcoal filter should only be installed if you are not using an external venting system Remove filter by lifting up the filter clip and rotating the filter downwards Place the cha...

Страница 13: ...TURNING ON OFF THE UNIT To turn on the fan press the appropriate speed control switch Low Speed 4 Medium Speed 3 High Speed 2 to select the desired level of power Once a button is pressed the previou...

Страница 14: ...move it Push in the new bulb 2 in the direction indicated until it locks into the socket Do not release the bulb until you are sure the bulb has been securely installed Then reconnect the power If new...

Страница 15: ...lutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow any deposits to remain for long periods of time on the range hood Rinse with water imm...

Страница 16: ...m detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Check that...

Страница 17: ...e Venting Options QR090 QR091 QR102 758 mm 29 8 in W 120V 60Hz 1 0A Push Button 300 10 High 2 x 5W LED GU10 base light bulb Top venting Back venting Recirculating Inside venting 354 mm 13 9 in D Mediu...

Страница 18: ...94 in 457 mm 18 in 758 mm 29 8 in 758 mm 29 8 in 220 mm 8 66 in 350 mm 13 78 in 93 mm 3 66 in 41 mm 1 6 in 80 mm 3 15 in 102 mm 4 in 28 mm 1 1 in 52 mm 2 04 in 655 mm 25 79 in 340 mm 13 38 in 378 mm 1...

Страница 19: ...e required part s and have the part number s ready A G H I J B C D E F K M N O L Part Description Code Quantity A Rectangular Damper QHR186 1 B Switch QHR187 1 C Bulb Holder QHR223 2 D LED Bulb QHR181...

Страница 20: ...098 cs conglomkb com service available in English and French Monday Friday from 8 30am 5pm EST www conglomkb com Made in China and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used...