background image

 14

 

Maintenance

REPLACING FILTERS

When filters need replacing, exchange with similar. Also replace 
filters that are damaged with punctures, bends, or broken 

frames .

 

-

Turn off the range hood and disconnect the power .

 

- Replace with an equivalent filter, then reconnect the 

power .

 

REPLACING LIGHT BULBS

 

When light bulbs burn out, replace them with a 5W GU10 base 

light bulb . 

 

-

Turn off the range hood, disconnect it from its power 
source, and ensure that the lights are cool .

 

-

Turn the bulb (1) in the direction indicated and pull it out 
to remove it .

 

-

Push in the new bulb (2) and turn it in the direction 
indicated until it locks into the socket . Do not release 
the bulb until you are sure the bulb has been securely 
installed . Then reconnect the power .

 

-

If new bulbs do not operate, ensure that they are 
inserted correctly .

DANGER: 

Turn off the power circuit breaker or the power 

switch on the junction box before performing maintenance . 
Touching circuitry inside the range hood while it is energized 
will result in death or serious injury .

WARNING:

 

Failure to replace worn out or damaged filters 

will increase the risk of fire.

 

  

WARNING:

 

Light bulbs can become hot when turned on . 

Do not touch bulbs until they are switched off and cooled . 
Touching hot bulbs could cause serious burns .

1

2

Содержание 457-8609

Страница 1: ...QR085 457 8609 QR086 457 8610 QR087 457 8611 OWNER S MANUAL UNDER CABINET RANGE HOOD...

Страница 2: ...ideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the l...

Страница 3: ...d burns Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flamin...

Страница 4: ...labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility...

Страница 5: ...r further assistance Pre Installation TOOLS MATERIALS REQUIRED NOT SUPPLIED Measuring tape Level Utility knife Pencil Certified Duct Tape Adjustable wrench Phillips screwdriver Flathead screwdriver Ne...

Страница 6: ...luminum charcoal filter 1 C Rectangular damper located inside the hood 1 D Round adapter located inside the hood 1 HARDWARE INCLUDED NOTE Parts not shown in actual size AA BB CC Part Description Quant...

Страница 7: ...iately sized wood filler strips 4 on each side using wood screws 3 Screws are provided to secure the range hood to most types of cabinets but consult a qualified installer to verify that the supplied...

Страница 8: ...ormance and use no more than three 90 elbows Ensure that there is a minimum of 458 mm 18 in of straight vent between each elbow Elbow as far away from the range hood s exhaust opening as possible Cap...

Страница 9: ...until smooth A hole through metal must have a grommet 10 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden utilities 11 Wire size must conform to all...

Страница 10: ...he range hood A FOR INTERIOR VENTING If you are venting indoors unscrew the screw holding cover 6 in place and remove the cover as per Fig 12 DO NOT REMOVE ANY OTHER VENTING HOLE COVER BB INSTALLING T...

Страница 11: ...U ARE USING EXTERIOR VENTING NOTE The charcoal filter should only be installed if you are not using an external venting system Turn the filter clip to either side and lift the aluminum filter Place th...

Страница 12: ...way leave the screw heads about 7 mm 0 28 in from the cabinet surface Lift the range hood A into position feeding the power cable and the electrical wires through the power access opening Allow some...

Страница 13: ...ach other TURNING ON OFF THE UNIT To turn on the fan press the appropriate speed control switch Low Speed 3 High Speed 2 to select the desired level of power Once a button is pressed the previous spee...

Страница 14: ...t Push in the new bulb 2 and turn it in the direction indicated until it locks into the socket Do not release the bulb until you are sure the bulb has been securely installed Then reconnect the power...

Страница 15: ...lutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow any deposits to remain for long periods of time on the range hood Rinse with water imm...

Страница 16: ...m detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Check that...

Страница 17: ...ulb Wattage Venting Options QR085 QR086 QR087 757 mm 29 8 in W 120V 60Hz 1 0A Push Button 250 10 High 2 x 5W LED GU10 base light bulb Top venting Back venting Recirculating Inside venting 450 mm 18 4...

Страница 18: ...mm 1 6 in 220 mm 8 66 in 158 mm 6 22 in 39 mm 1 53 in 378 mm 14 88 in 19 mm 0 75 in 305 mm 12 in 450 mm 17 7 in 52 mm 2 04 in 102 4 in 135 mm 5 31 in 178 mm 7 in 378 mm 14 88 in 220 mm 8 66 in 32 mm 1...

Страница 19: ...required part s and have the part number s ready P Q R Part Description Code Quantity A Rectangular Damper QHR186 1 B Switch QHR165 1 C Junction Box QHR166 1 D Motor QHR217 1 E Switch Plate QHR199 1 F...

Страница 20: ...098 cs conglomkb com service available in English and French Monday Friday from 8 30am 5pm EST www conglomkb com Made in China and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used...