Safety Information (continued)

COOKING SAFETY INFORMATION

1 .  Never leave the range hood unattended when in use . 

2 . 

Never cook over open flames under the range hood.

1 .  Always turn the range hood on when cooking at high heat  

or when cooking flaming foods.

2 .  If you choose to hang the range hood as below (Fig . 1) distance 

(D) from the cooktop surface, use extra caution as the surface 
of range hood may be extremely hot to the touch . For this unit, 
(D in Fig . 1) is 

458 mm - 710

 

mm (18 in - 28 in). If you choose 

an 18 inch installation, the temperature of the unit surface will 
be high if the unit is operated under high power cooking for a 
certain amount of time .

3 . 

Use caution when cooking with oil or with deep-fryers. 
Overheating may cause oil to reach its flash point and ignite. 

Used oil will ignite at lower temperatures than fresh oil . Heat 
oils slowly on low to medium setting .

4 .  Avoid boil overs, as they may cause smoking and greasy 

spillovers that could ignite .

5 . 

To prevent burns or fires, always use cookware appropriate to 

the size of the heating element that you are using .

6 . 

In event of a cooking fire, observe the following:

 

-

Be careful to avoid burns . 

 

- Smother flames with a close-fitting lid, cookie sheet, or 

metal tray, then turn off the burner. If the flames do not go 
out immediately, evacuate and call the fire department.

 

- Never pick up a flaming pan.

 

-

Do not use water, including wet dishcloths or towels, as you 
could cause a steam explosion .

 

- Use an extinguisher only if: (a) you have a class ABC 

extinguisher and you know how to operate it, (b) the fire is 
small and contained in the area where it started, (c) the fire 
department is being called, and (d) you can fight the fire with 

your back to the exit .

CLEANING SAFETY INFORMATION

1 . 

The fan and filters must be cleaned periodically and kept free 
from accumulation of cooking residue. Old and worn filters must 

be replaced immediately .

2 .  Never disassemble parts to clean . Parts should be disassembled 

by qualified persons only.

WARNING:

 

To reduce the risk of fire, use only metal duct 

work . Never use plastic duct work .

WARNING:

 

To reduce the risk of fire or electric shock, do 

not use this range hood with with any external solid state 
speed control device .

CAUTION: 

For general ventilation use only . Do not use the 

range hood fans to exhaust hazardous or explosive vapours .

CAUTION:

 

Never dispose of cigarette ashes, ignitable 

substances, or any foreign objects in fans .

CAUTION:

 

At least two people are needed to move and 

safely install the unit . Failure to properly lift the range hood 
could result in product damage or personal injury .

 

Содержание 457-8606

Страница 1: ...QR100 457 8606 QR101 457 8608 QR084 457 8607 OWNER S MANUAL UNDER CABINET RANGE HOOD...

Страница 2: ...ideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the l...

Страница 3: ...d burns Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flamin...

Страница 4: ...labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility...

Страница 5: ...r further assistance Pre Installation TOOLS MATERIALS REQUIRED NOT SUPPLIED Measuring tape Level Utility knife Pencil Certified Duct Tape Adjustable wrench Phillips screwdriver Flathead screwdriver Ne...

Страница 6: ...rcoal filter 1 C Rectangular damper located inside the hood 1 D Round adapter located inside the hood 1 HARDWARE INCLUDED NOTE Parts not shown in actual size AA BB CC DD Part Description Quantity AA L...

Страница 7: ...appropriately sized wood filler strips 4 on each side using wood screws 3 Screws are provided to secure the range hood to most types of cabinets but consult a qualified installer to verify that the su...

Страница 8: ...nce and use no more than three 90 elbows Ensure that there is a minimum of 458 mm 18 in of straight vent between each elbow Elbow as far away from the range hood s exhaust opening as possible Cap the...

Страница 9: ...ntil smooth A hole through metal must have a grommet 10 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden utilities 11 Wire size must conform to all l...

Страница 10: ...range hood A FOR INTERIOR VENTING If you are venting indoors unscrew the 2 screws holding cover 6 in place and remove the cover as per Fig 12 DO NOT REMOVE ANY OTHER VENTING HOLE COVER BB BB INSTALLI...

Страница 11: ...F YOU ARE USING EXTERIOR VENTING NOTE The charcoal filter should only be installed if you are not using an external venting system Turn the filter clip to either side and lift the aluminum filter Plac...

Страница 12: ...way leave the screw heads about 7 mm 0 28 in from the cabinet surface Lift the range hood A into position feeding the power cable and the electrical wires through the power access opening Allow some...

Страница 13: ...ach other TURNING ON OFF THE UNIT To turn on the fan press the appropriate speed control switch Low Speed 3 High Speed 2 to select the desired level of power Once a button is pressed the previous spee...

Страница 14: ...it out to remove it Push in the new bulb and turn it clockwise Do not release the bulb until you are sure the bulb has been securely installed Then reconnect the power If new bulbs do not operate ens...

Страница 15: ...lutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow any deposits to remain for long periods of time on the range hood Rinse with water imm...

Страница 16: ...m detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Check that...

Страница 17: ...del Dimensions Rating Control Type Max Fan CFM Speeds Light Bulb Wattage Venting Options QR100 QR101 QR084 757 mm 29 8 in W 120V 60Hz 1 5A Push Button 220 10 High 2 x 40W Incandescent E26 base light b...

Страница 18: ...75 in 655 mm 25 79 in 41 mm 1 6 in 220 mm 8 66 in 158 mm 6 22 in 39 mm 1 53 in 378 mm 14 88 in 19 mm 0 75 in 305 mm 12 in 450 mm 17 7 in 52 mm 2 04 in 102 4 in 189 mm 7 44 in 378 mm 14 88 in 220 mm 8...

Страница 19: ...e part number s ready A G H J K L M N P Q R S B C D E F Part Description Code Quantity A Rectangular Damper QHR186 1 B Switch QHR165 1 C Junction Box QHR166 1 D Motor QHR183 1 E Filter Clip QHR168 1 F...

Страница 20: ...098 cs conglomkb com service available in English and French Monday Friday from 8 30am 5pm EST www conglomkb com Made in China and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used...

Отзывы: