Westinghouse 457-8600 Скачать руководство пользователя страница 5

 

5 CONGLOMKB .COM

Please contact 

[email protected]

 or 

1-877-333-0098

 for further assistance .

Pre-Installation

TOOLS/MATERIALS REQUIRED (NOT SUPPLIED)

Measuring tape

Level

Utility knife

Pencil

Certified

 

Duct Tape

Adjustable 
wrench

Phillips screwdriver

Flathead 
screwdriver

Needle nose 
pliers

Hammer

Electric drill

Safety goggles

Safety gloves

Glue

Содержание 457-8600

Страница 1: ...QR098 457 8600 QR083 457 8601 QR099 457 8602 OWNER S MANUAL UNDER CABINET RANGE HOOD...

Страница 2: ...ideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the l...

Страница 3: ...d burns Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flamin...

Страница 4: ...labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility...

Страница 5: ...further assistance Pre Installation TOOLS MATERIALS REQUIRED NOT SUPPLIED Measuring tape Level Utility knife Pencil Certified Duct Tape Adjustable wrench Phillips screwdriver Flathead screwdriver Need...

Страница 6: ...ge hood 1 B Aluminum charcoal filter 1 C Retangular damper located inside the hood 1 D Strips 3 HARDWARE INCLUDED NOTE Parts not shown in actual size AA BB CC Part Description Quantity AA Long tapping...

Страница 7: ...here the range hood is to be installed is recessed attach appropriately sized wood filler strips 4 on each side using wood screws 3 Screws are provided to secure the range hood to most types of cabine...

Страница 8: ...of 458 mm 18 in of straight vent between each elbow Elbow as far away from the range hood s exhaust opening as possible Cap the exterior of the duct with a wall cap 15 or roof cap 16 Never use 102 mm...

Страница 9: ...A hole cut through wood must be sanded until smooth A hole through metal must have a grommet 10 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden util...

Страница 10: ...e venting indoors unscrew the 2 screws holding cover 6 in place and remove the cover as per Fig 12 DO NOT REMOVE ANY OTHER VENTING HOLE COVER 5 BB BB INSTALLING THE DAMPER SKIP THIS STEP IF YOU ARE US...

Страница 11: ...range hood A into position feeding the power cable and the electrical wires through the power access opening Allow some slack in the cable and wires so that the appliance can be moved if servicing is...

Страница 12: ...arcoal filter should only be installed if you are not using an external venting system Turn the filter clip to either side and lift the aluminum filter Place the charcoal filter B in place ensure that...

Страница 13: ...THE UNIT To turn on the fan press the appropriate speed control switch Low Speed 3 High Speed 1 to select the desired level of power Once a button is pressed the previous speed mode will be cancelled...

Страница 14: ...ull it out to remove it Push in the new bulb and turn it clockwise Do not release the bulb until you are sure the bulb has been securely installed Then reconnect the power If new bulbs do not operate...

Страница 15: ...lutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow any deposits to remain for long periods of time on the range hood Rinse with water imm...

Страница 16: ...m detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Check that...

Страница 17: ...lb Wattage Venting Options QR098 QR083 QR099 758 mm 29 8 in W 120V 60Hz 1 1A Rocker Switches 160 10 High 1 x 40W Incandescent E26 base light bulb Top venting Back venting Recirculating Inside venting...

Страница 18: ...AL DIAGRAM OF RANGE HOOD 10 3 1 8 1 2 1 4 3 8 8 3 4 6 1 4 4 1 16 13 11 16 1 5 8 1 9 16 27 3 4 25 13 16 9 13 16 2 1 16 1 1 16 7 8 7 7 16 1 5 8 8 7 8 10 9 13 16 29 13 16 1 2 3 3 8 7 8 7 7 16 13 16 10 1...

Страница 19: ...B Rocker Switches Left Right QHR212 1 C Capacitor QHR213 1 D Motor QHR214 1 E Filter Clip QHR168 1 F White Filler Strips QHR190 3 F Stainless Steel Filler Strips QHR220 3 F Black Filler Strips QHR221...

Страница 20: ...098 cs conglomkb com service available in English and French Monday Friday from 8 30am 5pm EST www conglomkb com Made in China and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used...

Отзывы: