Step 2
Utilize twist-on connectors to make electrical connections (FIG. 5, 6). All electrical connections must remain
inside back box. Fasten the wires by a provided cable tie, prior to closing and securing enclosure. Tighten
enclosure screw to seal fixture. (FIG.3)
Step 3
Please refer to FIG.4 for location for the photocell (Optional).
2.
Mounting Pole
Step 1
Screw the Mounting Pole on the back box (FIG.7, 8)
Step 2
Please refer to FIG.5 or FIG.6 for wiring, remove the screw at the knuckle of the Mounting Pole by screw
driver
,
put the wires pass through the hole of the Mounting Pole.
Step 3
Route electrical leads through the 1/2" NPS cover plate (supplied by others).
Seal knuckle threads with sealing compound (provided by others).
Secure cover plate to knuckle with lock nut (50-60 in-lbs). Make wire connection in outdoor rated junction
box. Mount cover plate to junction box. (FIG.9)