WESTFIRE·WF
36
WF
37
14
UK
Operation with door left open
Operation with the door open can causeexcesssmoke. The appliance must not be operated with the appliance
door left open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excesssmoke. The appliance must not be
operated with air controls, appliance dampers or door left open except asdirected in the instructions.
Fuel Overloading
Themaximum amount of fuel specified in this manual should not be exceeded, overloading can causeexcess
smoke.
Annual service
Theinside of the stove should be serviced /cleaned once a year. To clean the inside, remove all ash, soot and tar
residue from the combustion chamber. Removeinsulated chamber panels and baffle, dirt and soot will collect
behind it and this must be cleaned out. Insulated panels may crackif hit too hard by a piece of firewood. Thishas no
effect on the function of the stove (this is not the casewith the smoke plate). The Insulated panels will only need to
be replaced once they become very worn and are no longer whole, or if they crack in several places. Checkglassis
correctly positioned, replace stove door rope cord in the door. Checkglass is correctly positioned.
Thestove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The
chimney should also be checkedfor blockages before relighting the stove if it has not been used for an extended
period of time.
Thepaint/ lacquer can wear thin in exposed places due to overheating. This,and other lacquer damage, may be
repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer.
Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.
TROUBLESHOOTING, CHECKTHEFOLLOWING:
1. Fire Will Not Burn
a)
the air inlet is not obstructed in any way,
b)
that chimneys and flueways are clear,
c)
that a suitable fuel is being used,
d)
that there is an adequate air supply into the room,
e)
that an extractor fan is not fitted in the same room asthe fire.
2. Fire Blazing Out Of Control
a)
the doors are tightly closed,
b)
the air control is turned down to the minimum setting,
c)
the air inlet damper is closed and that it is not prevented from closing completely by a piece of ash,
d)
a suitable fuel is being used,
e)
the door seals are in good condition.
f)
the chimney draft may be too strong
g)
check ash pan seal and
h)
check for ash below ash pan causing pan to not seat correctly and clean out.
3. Sootforms on the window
a)
Thefirewood may be too wet
b)
the intake of secondaryair may be insufficient
c)
fire not hot enough
4. The stove fails to heat fully
a)
Thefirewood may be too wet
b)
the intake of secondaryair may be insufficient
Содержание UNIQ37