Translated into English by
www.westfaliaLT.info
– a useful website for VW Westfalia LT Camper enthusiasts.
220 V Mains Operation:
Outlets and battery charger are supplied
directly. The mains fuses (10 amp) that are located in the outer socket are
accessible from the front inside the van.
All the 12 V living equipment is still fed by the second battery but
depending on the position of the switch the power supply now backs up
the battery.
This mode allows an almost unlimited operational time.
During driving the starter battery and auxiliary battery are charged from
the alternator. The position of the toggle switch does not matter.
Control panel for battery charger at the bottom of wardrobe.
Control Panel
A green control light shows that the mains equipment is on.
The 12 V equipment is protected by the 10 amp circuit breaker.
By using the switch the output of the mains equipment can be directed to
either the starter battery or auxiliary battery.
Overcharging of the battery is prevented by electronically regulated
charging current.
www.westfaliaLT.info - a useful site for enthusiasts and owners of VW Westfalia LT campers