Westfalia 94 54 47 Скачать руководство пользователя страница 15

 

 

11 

Operation 

have to be sealed with duct tape. 

 

When  using  for 

opening  toilet  drains

,  fill  the  toilet  with  water.  The 

water level must be higher than the toilet bowl attachment. 

Flush lower floor toilets to be sure they are clear before using the drain 
cleaner on upper floor toilets. 

If necessary, use a splash guard foil to protect against possible splash. 
Drape the protection foil over the rim of the bowl and secure the edges 
of the foil with duct tape. 

 

When  using  the  drain  cleaner  for 

opening  exterior  drains

,  pay 

attention to the water level. The system must be full of water. Add water 
to the system if necessary.  

For  drain  systems  with  multiple  openings  begin  by  using  the  drain 
cleaner closest to clog while plugging all adjacent openings. 

Repeat  steps  as  necessary  with  each  of the  other  openings  upstream 
until the drain system flows normally. 

Operation 

1.  Prepare the drain cleaner 

as described in chapter “

Assembling

”. 

2.  When  using  the  drain  cleaner  on  any  exposed  drain  traps,  be  sure  to 

support the bottom of the trap with a strong, non-flexible object, e.g. a 
sturdy  pot,  a  book,  etc.  The  drain  cleaner  uses  air  pressure  to  work. 
Failure  to  support  any  exposed  drain  trap may  result  in the  drain  pipe 
fitting  become  loose  due  to  the  compression.  Unexposed  drain  traps 
used in showers, bath tubs, etc. do not need support. 

3.  Put the drain cleaner on a firm and flat surface. Use the pump lever (6) 

to  pump  air  into  the  air  reservoir  (3).  Pump  until  you  feel  a  strong 
resistance (normally this occurs after approx. 20 to 30 strokes). 

4.  Run water in the obstructed drain until the water level reaches the drain 

opening.  Place  the  drain  cleaner  on  the  blocked  drain  opening.  A 
pressure-resistant sealing is important. 

5.  Firmly hold the  drain cleaner with both hands.  One hand holds the air 

reservoir (3) and the other hand holds the handle (5). Quickly press the 
trigger  (4).  The  air  rapidly  escapes  from  the  air  reservoir  through  the 
clogged pipe and clears the obstruction in the drain. 

6.  Slowly  lift  the  drain  cleaner  from  the  drainage  and  immediately  flush 

with  plenty  of  running  water.  If  necessary,  repeat  the  process  several 

Содержание 94 54 47

Страница 1: ...Profi Druckluft Rohrreiniger 5 tlg Artikel Nr 94 54 47 5 Pcs Pro Drain Cleaner Article No 94 54 47 Originalanleitung Original Instructions...

Страница 2: ...nd keep it for future reference Bedienungsanleitungen enthalten wichtige Hinweise f r den Umgang mit Ihrem neuen Produkt Sie erm glichen Ihnen alle Funktionen zu nutzen und sie helfen Ihnen Missverst...

Страница 3: ...III bersicht Overview 2 3 4 1 5 6 7 9 10 8...

Страница 4: ...gelgelenk Air Vent with Ball Joint 3 Druckbeh lter Air Reservoir 4 Abzug Trigger 5 Handgriff Handle 6 Pumpenhebel Pump Lever 7 Aufsatz klein Attachment small 8 Aufsatz mittel Attachment middle 9 Aufsa...

Страница 5: ...Seite 7 Benutzung Seite 8 Hinweise Seite 9 Sicherheitsventil Seite 9 Reinigung und Lagerung Seite 9 Table of Contents Safety Notes Page 4 Assembly Page 11 a Using on most Sink Openings Page 11 b Using...

Страница 6: ...n in Sp lbecken Badewannen Duschen oder Toiletten Verwenden Sie den Abflussreiniger nicht wenn sich noch R ckst nde von chemischen Reinigern im Abfluss befinden Verwenden Sie den Abflussreiniger nicht...

Страница 7: ...ded for use with water drains used in sinks bathtubs showers or toilets Do not use the drain cleaner if chemical drain cleaners are present in the pipes Do not use this drain cleaner in freezing condi...

Страница 8: ...les toilettes Ne pas utiliser le produit de d bouchage s il ya des r sidus de produits chimiques de nettoyage dans les eaux de ruissellement Utiliser les nettoyeurs de drains n a pas de tuyaux ou syst...

Страница 9: ...acqua pi pulita di scarico scarichi in lavandini vasche docce e servizi igienici Non usare il pulitore di scarico non se ci sono ancora residui di detergenti chimici gi per lo scarico Utilizzare i pul...

Страница 10: ...icht wenn sich noch R ckst nde von chemischen Reinigern im Abfluss befinden berpr fen Sie den festen Sitz der Verbindungen Ihres Abflusssystems Verwenden Sie den Abflussreiniger nur bei einwandfreien...

Страница 11: ...beband an der Toilette fest Benutzung f r Au enabfl sse Bei Abflusssystemen mit mehreren Abfluss ffnungen verwenden Sie den Abflussreiniger als erstes an der ffnung die der Verstopfung am n chsten ist...

Страница 12: ...berlauf ffnungen anschlie end wieder Hinweise Der Abflussreiniger kann auch als vorbeugende Ma nahme verwendet werden wenn noch keine starke Verstopfung vorliegt Bei starken Verstopfungen die durch F...

Страница 13: ...n befeuchtetes Tuch Verwenden Sie keine kratzenden oder scheuernden Reinigungsmittel bzw Chemika lien Lagern Sie den Abflussreiniger au er Reichweite von Kindern an einem trockenen vor Staub Schmutz u...

Страница 14: ...re present in the pipes Check if all tubes of the drain system are firmly connected Only use the drain cleaner if the tubes are properly connected When using the drain cleaner for opening sink opening...

Страница 15: ...r on any exposed drain traps be sure to support the bottom of the trap with a strong non flexible object e g a sturdy pot a book etc The drain cleaner uses air pressure to work Failure to support any...

Страница 16: ...tubes of the drain system are still firmly connected Safety Valve The safety valve is preset by factory If pressure becomes too high air is released through the safety valve Turn the knob of the safet...

Страница 17: ...V Notizen Notes Notizen Notes Notizen Notes Notizen Notes...

Страница 18: ...r Kunde bitte helfen Sie mit Abfall zu vermeiden Sollten Sie sich einmal von diesem Artikel trennen wollen so bedenken Sie bitte dass viele seiner Komponenten aus wertvollen Rohstoffen bestehen und wi...

Отзывы: