13
Operation
Calibration
The digital spirit level has been calibrated in the factory for
maximum accuracy. If necessary, the digital spirit level
can be re-calibrated.
1. Clip the digital spirit level to a spirit level (
Fig. 1
).
2. Switch on the digital spirit level. Use an object that is
fine but not too sharp to press the recessed calibration
key CAL (7). The buzzer (3) starts to beep (
Fig. 2
).
3. Place the digital spirit level on a flat and level surface
and press the MODE key (6) once. Wait for a few
seconds until the buzzer beeps.
4. Place the spirit level reverse horizontal by 180º and
press the MODE key once. Wait until the buzzer beeps
(
Fig. 3
).
5. Place the spirit level vertically (in a right angle) and
press the MODE key once. Wait until the buzzer beeps
(
Fig. 4
).
6. Flip over the spirit level by 180º and press the MODE
key once. Wait until the buzzer beeps (
Fig. 5
).
7. Calibration is completed when the buzzer has stopped
beeping.
Note: Ensure the digital spirit level is kept absolutely
steady during calibration.