Synchronisation 

 
Stand alone 

If no synchronisation the T/T works as stand alone. 
 

 
Minute impulse 

Set the straps according to the strapping schema page 6. 
Connect the wires, see page 5. 
The T/T could be set for synchronisation or slave mode.  
Synchronisation mode: 
Set the T/T in synchronisation mode InSy, see programming page 10. 
Set time and wait for next minute impulse. It is now synchronised. 
Slave mode: 
Set the T/T in slave mode InSL, see programming page 10. 
Set time and wait for next minute impulse. It is now working in slave mode. 

 
TC 

Set the straps according to the strapping schema page 6. 
Connect the  TC wires, see page 5. 
Set the T/T in synchronisation mode sync. Functions DCF see programming page 10. 
After one correct accepted time message the time is displayed and the colon starts flashing on and off.  
 
 

DCF 

Set the straps according to the strapping schema page 6 and 7. 
Connect the DCF wires, see page 5. 
Set the T/T in synchronisation mode sync. Functions DCF see programming page 10. 
After one correct accepted time message the time is displayed and the colon starts flashing on and off.  
 

Содержание 190130-30

Страница 1: ...An Date 2011 12 29 Page 1 av 17 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Manual Westerstrand T T displa...

Страница 2: ...PPING DCF RADIO 2 WIRE COMPUTER BOARD 6 STRAPPING DCF RADIO 3 WIRE COMPUTER BOARD 7 SYNCHRONISATION 8 CONNECTION TEMPERATURE SENSOR OPTION 9 PROGRAMMING 9 Manual programming time 10 Setting light inte...

Страница 3: ...nd temperature in 1 25 seconds intervals This device is for use alternatively as digital clock or as chronometer 7 segments LED digits in dimensions 150 190 250 300 and 450 mm The time and temperature...

Страница 4: ...urned off The internal clock continues to keep the correct time for 48 hours After power failure the display is turned on and correct time is shown Installation TC l1 Installation Mount the clock by m...

Страница 5: ...terstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection Connection synchronisation TC and MIN imp is connected at IMP and IMP V IMP IMP DCF DCF 2 wire is connected V and GN...

Страница 6: ...29 Page 6 av 17 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Strapping TC MIN impulse computer board defaul...

Страница 7: ...c Auth TAn Date 2011 12 29 Page 7 av 17 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Strapping DCF radio 3...

Страница 8: ...r next minute impulse It is now synchronised Slave mode Set the T T in slave mode InSL see programming page 10 Set time and wait for next minute impulse It is now working in slave mode TC Set the stra...

Страница 9: ...506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection temperature sensor option Temperature sensor connection 1 red 2 black 3 Screen 1 2 3 TEMP...

Страница 10: ...ction Accept displayed value P Program Enter the displayed function Increase displayed value Manual programming time Push F until display shows Push P display shows year Push P until desired year 00 9...

Страница 11: ...y The light intensity for the digits has one minimum and one maximum level The setting levels 1 50 are set in function disp An automatic dimmer function regulates the light intensity between minimum a...

Страница 12: ...westerstrand se Setting synchronisation Synchronisation for this model is minute impulse TC DCF or stand alone Push F until display shows Push P for desired synchronisation No synchronisation stand a...

Страница 13: ...esired alternating temperature 0 25 Accept with F Display shows Alternating time for display date is 4 seconds Push P for desired alternating time 0 25 Accept with F Push R for entering base mode or p...

Страница 14: ...can be set Push F until display shows Push P Display shows 12 hour format or 24 hour format Push P for desired format Push R for entering base mode or push F for next function Function as chronometer...

Страница 15: ...is monitored from a remote control unit with seven buttons MODE S S PRESET NO YES och MODE For the change between chronometer and clock S S Start stop PRESET Reset of time Reset can only be done when...

Страница 16: ...ows noAU or AUto In setting AUto the chronometer starts unconditionally when MODE is pressed from the clock mode Press NO until selected text is shown Press YES Display shows HnS Hn nSC nS nnS or nnC...

Страница 17: ...ow 00 01 00 Technical specification Common Mains 230 VAC 50Hz 10 Temperature range 20 C 40 C Synchronisation Polarised 24V impulse 1 1 TC DCF Accuracy 0 1 sek 24 hour Running reserve 48 hour Changing...

Отзывы: