Lit. No. 99761/99762, Rev. 02
16
January 1, 2017
OPERATING THE SPREADER – CAB CONTROL
Setup Codes
Code
Definition
Procedure
Cb
Calibrate the Empty Hopper setting.
With control in ON mode, press and hold the left control knob until the
Cb
code displays. Calibration cycle is automatic.*
Cc
Clear calibration data for Empty Hopper
setting; clear EH code.
Press the right control knob to clear all calibration data during the
calibration cycle.
LS
Set LED brightness level.
With control in Ready mode, press and hold left control knob to get
LS
code. Release pressure and turn left control knob to desired
brightness setting. Wait for confirming
SL
code to display.*
SL
Confirms that LED brightness level has
been reset.
*
For full instructions, see the "Setup Procedures" section.
Information Codes
Code
Definition
Response
dU
Spreader is in dump mode:
• Material chute is open.
• Back Dump buttons are enabled.
To operate the dump function, see instructions in the "Operating the
Spreader" section of this manual.
If
dU
code displays when the material chute is closed and latched,
contact authorized dealer.
EH
Empty hopper (beep will sound).
Check hopper for material.
Recalibrate Empty Hopper setting as described above for
Cb
code.
Lb
Low battery. Hopper module is sensing
< 10V. (
Lb
becomes an error code
when module senses < 6V.)
Refer to the
Lb
row under "Error Codes" (next page).
CAB CONTROL CODES