WD1003-WA2 JUMPER SETTINGS
PIN CONNECTS
DESCRIPTION
NOTE
DO NOT MOVE PRIMARY ADDRESS JUMPERS
UNLESS YOUR OPERATING SYSTEM IS CONFIGURED
TO ACCEPT TWO HARD DISK CONTROLLERS.
CERTAIN OPERATING SYSTEMS SUPPORT TWO
CONTROLLERS IN THE SAME SYSTEM. IBM DOS AND
MANY IBM-COMPATIBLE OPERATING SYSTEMS DO
NOT SUPPORT THIS FEATURE.
E2 to E3
Standard factory setting. Selects primary addresses.
E5 to E6
Standard factory setting. Selects primary addresses.
El to E2
Selects secondary addresses.
E4 to E5
Selects secondary addresses.
E7 to E8
Standard factory setting. Supports 360 RPM floppy disk drives.
ES to E9
Jumper in this position selects 300 RPM floppy disk drives.
6
SOFTWARE INSTALLATION
This section contains instructions for preparing (low level
format, etc.) your operating system to recognize the Western
Digital controller.
1. Insert your system Diagnostic Diskette (or equivalent).
2. Turn on the power
3. Boot diagnostic and select setup option.
4. Set clock etc.
CAUTION
Avoid system damage by consulting your
Technical Reference manual to ensure that your
drive type is supported by your host BIOS drive
tables. Not all AT-compatibles share the same
drive tables as IBM.
5. Select proper drive type. Consult your Technical Refer-
ence Manual for further information on these parameters.
NOTE
Step 6 requires execution of low level formatting. Use of the
IBM Advanced Diagnostic (or similar program for IBM-
compatibles) is necessary since these controllers contain no
on-board Basic Input/Output System (BIOS) ROM.
6. Insert your Advanced Diagnostic diskette and execute
low level Format. Follow instructions in your reference
manual.
7. Insert System Diagnostic Diskette (or equivalent) after
the system finishes the low level format.
8. Load and execute the FDISK and FORMAT programs.
Follow instructions in your reference manual.
7
If you require further information or
other technical support, please contact
your authorized dealer:
F.C.C. CERTIFICATION
THESE WESTERN DIGITAL PRODUCTS HAVE BEEN CERTIFIED TO COMPLY WITH THE LIMITS
FOR A CLASS B COMPUTING DEVICE PURSUANT TO SUBPART J OF PART 15 OF F.C.C. RULES.
THIS DOES NOT GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN INDIVIDUAL
INSTALLATIONS. WESTERN DIGITAL IS NOT RESPONSIBLE FOR ANY TELEVISION, RADIO, OR
OTHER INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS OF THIS PRODUCT.
IF INTERFERENCE PROBLEMS DO OCCUR, PLEASE CONSULT THE SYSTEM EQUIPMENT
OWNER’S MANUAL FOR SUGGESTIONS. SOME OF THESE SUGGESTIONS INCLUDE
RELOCATION OF THE COMPUTER SYSTEM AWAY FROM THE TELEVISION OR RADIO OR
PLACING THE COMPUTER AC POWER CONNECTION ON ANOTHER CIRCUIT OR OUTLET.
THIS PRODUCT WAS TESTED AND CERTIFIED WITH EXTERNAL SHIELDED INTERCONNECTING
CABLE(S). THEREFORE, SHIELDED CABLE(S) IS (ARE) REQUIRED TO BE USED WITH THIS
PRODUCT.
IBM, AT AND IBM PERSONAL COMPUTER AT ARE REGISTERED TRADEMARKS OR
INTERNATIONAL BUSINESS MACHINES CORPORATION.
COMPAQ 286 IS A REGISTERED TRADEMARK OF COMPAQ COMPUTER CORPORATION.
COPYRIGHT 1987 WESTERN DIGITAL CORP
ALL RIGHTS RESERVED.
This document is protected by copyright, and contains information proprietary to Western Digital Corp. Any
copying, adaptation, distribution, public performance, or public display of this document without the express
written consent of Western Digital Corp. is strictly prohibited. The receipt or possession of this document
does not convey any rights to reproduce or distribute its contents, or to manufacture, use or sell anything that it
may describe, in whole or in part, without the specific written consent of Western Digital Corp.
Western Digital
2445 McCabe Way
Irvine, California 92714
(800) 847-6181
WI2IOS 5/87 l00M
79-000063
8