Western Digital WD 1003-RA2 Скачать руководство пользователя страница 3

WDl003-RAH JUMPER SETTINGS

JUMPER

PIN CONNECTS

DESCRIPTION

W1

1-2

Standard factory setting. Status read is latched. Used for IBM
Personal Computer AT if Winchester activity LED is connected to
J6.

OPEN

Status read is not latched. Activity LED turns on during drive
access. W5 must be jumpered 2 to 3. Used for Compaq hosts.

W2

OPEN

Standard factory setting. Selects primary addresses, 1F0 through
1F7 and 3F0 through 3F7 hex. Do not modify the primary address
jumper unless your BIOS operating system is configured to accept
more than two hard disk drives.

1-2

Selects secondary addresses, 170 through 177 and 370 through
377 hex.

W3

OPEN

1-2

This configuration used with WD11C00C-22 at board location US
or if W5 is jumpered 1 to 2. Required only on early units with
WD11C00-22 at board location U8 and W5 is jumpered 1 to 2. DO
NOT JUMPER WITH THE WDl1C00C-22 INSTALLED.

W4

2-3

Standard factory setting. No translation for drive 0.

1-2

Enables translation for drive 0. Translation is only available for
615 cylinders and four headed drives. In translation mode, the
controller translates the 26 physical sectors per track into 17
sectors. The extra sectors are "translated" into logical heads. To
use the translation mode, select through the Setup program a 615
cylinder and six head drive type. (This is drive type three for IBM
Personal Computer AT users. Not all AT-compatible systems use
the same drive tables as IBM.) This configuration must be used
when running an operating system or application program which
requires a 17 sector per track disk drive.

W5

2-3

Standard factory setting. WG and drive select lines only enabled
when drive is accessed. This configuration also provides power up
and down protection.

1-2

WG and drive select lines are disabled during power up reset and
when  + 5V  power supply drops below approximately  +4.1 5V.

W6

2-3

Standard factory setting. No translation for drive 1.

1-2

Enables translation for drive 1. Translation is only available for
615 cylinders and four headed drives. In translation mode, the
controller translates the 26 physical sectors per track into 17
sectors. The extra sectors are "translated" into logical heads. To
use the translation mode, select through the Setup program a 615
cylinder and six head drive type. (This is drive type three for IBM
Personal Computer AT users. Not all AT-compatible systems use
the same drive tables as IBM.) This configuration must be used
when running an operating system or application program which
requires a 17 sector per track disk drive.

Содержание WD 1003-RA2

Страница 1: ...USER S GUIDE WD 1003 RAH WD 1003S RAH WD 1003 RA2 WD 1003A RA2 Winchester Disk Controllers Important Information Do not Discard...

Страница 2: ...translation operation only Feature 001 F00l Translation operation only The other controllers described in this document have one standard version These controllers are designed for use in IBM Personal...

Страница 3: ...translated into logical heads To use the translation mode select through the Setup program a 615 cylinder and six head drive type This is drive type three for IBM Personal Computer AT users Not all AT...

Страница 4: ...he closest available expansion slot relative to the drive CAUTION Handle the controller board by the ends of the board Some of the chips are static sensitive and damage may occur if the board is incor...

Страница 5: ...d when drive is accessed This configuration also provides power up and down protection 1 2 WG and drive select lines are disabled during power up reset and when 5V power supply drops below approximate...

Страница 6: ...ble mates with pin 1 on the connector Pin 1 is clearly marked on the board s connectors Pin 1 on the cables is usually on the color coded side 4 WD1003 RAH Attach 34 pin control connector to J1 WD1003...

Страница 7: ...pin floppy cable connector to J5 10 WD1003 RAH WD1003S RAH WD1003 RA2 Attach Winchester activity LED connector to J6 WD1003A RA2 Attach Winchester activity LED to Jl 11 Install the controller board in...

Страница 8: ...through 1F7 hex for the hard disk controller Do not modify the primary address jumper unless your operating system is configured to accept more than two hard disk drives Also verify that ES and E6 ar...

Страница 9: ......

Страница 10: ...W4 3 5 Standard factory setting Selects primary addresses 1F0 through 1F7 hex for the hard disk controller Do not modify the primary address jumper unless your operating system is configured to accep...

Страница 11: ...for Non Translation Mode NOTE Formatting disk media with this operational mode requires a host system with a 26 sector BIOS If the system does not contain a 26 sector BIOS Ontrack and Storage Dimensio...