User Guide
1. Overview
1.9 Power Requirements
Parameter
Rack
PDU (Vertical)
PDU Mounting
Bracket
Additional Mounting
Bracket Hardware
SREXTENDER
48U (Rack
Extension)
Quantity
1 rack
2
1
N/A
Table 16:
Compatible Hardware Configuration 4
Parameter
Rack
PDU (Vertical)
PDU Mounting
Bracket
Additional Mounting
Bracket Hardware
Vendor
APC/Schneider
Server Technology
Server Technology
Various
Part
Number
AR3300W
412-0761-11_STV-4501
412-0761-20_STV-4502
412-0761-23_STV-4503
KIT-MBVPT-1B
(one kit per PDU)
4 x M6 x 16 Hex
Cap Screws
8 x M6 Fender
Washers
4 x M6 Hex Nut
with Nylon Lock
Quantity
1 rack
2
2
Varies
1.9
Power Requirements
The following table describes the A/C input power specification for the Ultrastar 8.
Table 17:
AC Power Specifications
Power
Alternating Current (AC) Power Supply (2 per enclosure)
Wattage (per power supply)
Supply Rating:
80 PLUS Platinum rated
Max Power Consumption:
~2000W
Typical Power Consumption:
~1800W
Voltage (per power supply)
200 - 240 VAC, auto-ranging, 50/60 Hz
Maximum inrush current (per power
supply)
AC line inrush current shall not exceed 35A peak
measured per IPC-9592B(L) Appendix C-4.1.
Caution:
The Ultrastar 8 can only be plugged into high line (220-240 VAC). If the unit is
plugged into low line (110-127 VAC), the PSU will report a "Critical" state when status pages are
queried using SES. In this case, the enclosure will power up, but the drives will not.
* Max and typical power consumption values represent the output power to the system. Input power will vary depending
on the PSU efficiency and load sharing between PSUs.
18