Western Digital scorpio black mx320s-1 Скачать руководство пользователя страница 29

WD Scorpio ML320S-AF2

Product Features

2679-771320-A00

RELEASED 4/7/11 (WD CONFIDENTIAL)

21

3.7

Hot Plug Support

SATA supports hot plugging (also known as “hot swapping”), the ability to swap out a failed hard drive 
without having to power down the system or reboot. This capability contributes to both data 
availability and serviceability without any associated downtime, making it a critical feature for 
extending SATA into enterprise applications.

WD SATA drives support hot plugging only in systems where a SATA hard drive storage backplane is 
used.

The  Serial ATA revision 2.5 specification requires staggered pins for both the hard drive and drive 
receptacles. Staggered pins mate the power signals in the appropriate sequences required for powering 
up the hot plugged device. These pins are also specified to handle in excess of the maximum allowed 
inrush current that occurs during drive insertion. SATA-compliant devices thus need no further 
modification to be hot pluggable and provide the necessary building blocks for a robust hot plug 
solution, which typically includes:

„

Device detection even with power downed receptacles (typical of server applications).

„

Pre-charging resistors to passively limit inrush current during drive insertion.

„

Hot plug controllers to actively limit inrush current during drive insertion.

3.7.1

Hot Plug Technical Issues

Reliable hot plugging of disk drives requires careful design of specific issues. Generally, hot plugging is 
only allowed when blind mating with a backplane, where there are controlled tolerances for alignment 
of mating connectors. The main issue is preventing droop (a momentary drop in voltage) of the 
backplane's voltage busses during insertion because of inrush current to charging bypass capacitors in 
the disk drive.

3.7.1.1

Methods of Controlling Inrush Current

There are two methods of limiting inrush current when hot plugging disk drives. They are hot plug 
controller IC's and precharge resistors.

3.7.1.1.1 Hot Plug Controller IC's

Hot plug controller IC's ramp up voltages to the inserted disk drive at a controlled slow rate (a constant 
dv/dt), after full connector mating has been established. This eliminates almost all inrush current. This 
method does not require staggered precharge contacts, although there usually is a staggered ground 
'mate first' pin(s) to ensure ground connection before making power and signal connections. 
Sometimes added ground pins on both ends of the mating connector are staggered 'mate last' providing 
the hot plug controller a clear indication of all other pins making solid contact. From an engineering 
standpoint, this is the most reliable method of hot plugging disk drives, but is expensive to implement 
on backplanes.

3.7.1.1.2 Precharge Resistors

Current limiting series precharge resistors on designated power pins make contact before hard power 
connection is made, providing controlled partial charge of the disk drive's decoupling capacitors. This 
partial charge is due to IR drop across the precharge resistor caused by disk drive DC loads at partial 
power. A second current surge occurs when final power connections are made, completing charge of 
the decoupling capacitors. Use of precharge resistors requires three stages of contact sequencing on the 
mating connector. The first stage makes initial ground contact, establishing a ground reference between 
the disk drive and backplane. It also discharges any ESD voltage between the two devices. The second 
stage contacts connect the precharge resistors, supplying limited current to the inserting disk drive's 
voltage busses. This allows partial charging of decoupling capacitors on the disk drive. Stage three 
contacts make hard power and signals connections. The ideal value for precharge resistors is where peak 
inrush current for both the precharge resistor connections and final hard power connections are similar 
in amplitude. Even with precharge resistors, there may be some momentary droop of the backplane 

Содержание scorpio black mx320s-1

Страница 1: ...Technical Reference Manual WD CONFIDENTIAL WD3200BPVT WD2500BPVT WD Scorpio Blue ML320S AF2 SATA Hard Drives...

Страница 2: ...D logo and WD Scorpio are registered trademarks in the U S and other countries and Data Lifeguard CacheFlow and FIT Lab are trademarks of Western Digital Technologies Inc Other marks may be mentioned...

Страница 3: ...2679 771320 A00 RELEASED 4 7 11 WD CONFIDENTIAL WD Scorpio ML320S AF2 WD3200BPVT WD2500BPVT Technical Reference Manual...

Страница 4: ...RELEASED 4 7 11 WD CONFIDENTIAL 2679 771320 A00...

Страница 5: ...itions 12 2 8 Agency Approvals 13 2 9 Full Model Number Specification 13 3 PRODUCT FEATURES 14 3 1 SATA 3 Gb s and SATA 1 5 Gb s 15 3 2 Perpendicular Magnetic Recording PMR 15 3 3 Reduced Power Spinup...

Страница 6: ...Commands 28 4 2 S M A R T B0h 28 4 2 1 Read Attribute Values Sub Command 28 4 2 2 Supported Attributes 30 4 2 3 Read Log Sector 31 4 2 4 Offline Data Collection 31 4 3 Identify Device ECh 32 4 4 Set F...

Страница 7: ...ring Spinup 7 Figure 2 3 Drive Base Casting Thermocouple Location 9 Figure 2 4 Forced Airflow Direction 10 Figure 2 5 Standard Factory Connectors 11 Figure 3 1 RPS Spinup Profile 15 Figure 5 1 Drive H...

Страница 8: ...ce Pin Connector Pin Definitions 11 Table 2 3 Full Model Number Description 12 Table 4 1 ATA 7 ATA 8 Command Opcodes 26 Table 4 2 SATA 2 5 Command Opcodes 27 Table 4 3 Obsolete Command Opcodes 27 Tabl...

Страница 9: ...he SCT Command Transport feature set provides a method for a host to send commands and data to a device and for a device to send data and status to a host using log pages Reliability Features Set Data...

Страница 10: ...erforming offline data collection it automatically relocates the sector without end user intervention Self Monitoring Analysis and Reporting Technology S M A R T S M A R T enables a drive s internal s...

Страница 11: ...required to keep the VCM motor from overheating s seek performance will be impacted under this condition 2 As used for storage capacity one megabyte MB one million bytes one gigabyte GB one billion by...

Страница 12: ...thod Partial DC Target Partial DC Target ECC Reed Solomon Reed Solomon 1 As used for storage capacity one megabyte MB one million bytes one gigabyte GB one billion bytes and one terabyte TB one trilli...

Страница 13: ...WD CONFIDENTIAL 5 2 2 1 Physical Dimensions English Metric Dimension Tolerance Dimension Tolerance Height 0 374 inches 0 01 inch 9 50 mm 0 20 mm Length 3 94 inches 0 01 inch 100 20 mm 0 25 mm Width 2...

Страница 14: ...ows the mounting dimensions and locations of the screw holes for the drive Figure 2 1 Mounting Dimensions 2x 61 72 4x 4 60 MIN 100 20 0 25 2x 76 60 2x 4 07 4X M3 THREAD 2 5mm FULL THREAD DEPTH MIN C B...

Страница 15: ...Spinup Note Current is 200 mA per 10 mV vertical deflection Operating Mode Current1 Power1 5 VDC Spinup max 950 mA 4 75W Read Write average 320 mA 1 6W Seek average 320 mA 1 6W POWER MANAGEMENT COMMA...

Страница 16: ...exceeding the level listed in Table 2 1 Operating performance may degrade during periods of exposure to continuous vibration Non Operating Vibration Note This specification applies to handling and tra...

Страница 17: ...horizontally in a free free state and measuring the side to side vibration Self vibration may not exceed the level listed in Table 2 1 Rotational Shock Non Operating Drives are tested by applying a r...

Страница 18: ...mperature2 60 C 140 F Humidity 8 90 RH non condensing 29 4 C maximum wet bulb Thermal Gradient 20 C hour maximum Humidity Gradient 20 hour maximum Non operating Temperature 40 C to 65 C 40 F to 149 F...

Страница 19: ...vironment by restricting the use of certain hazardous substances in new equipment and consists of restrictions on lead mercury cadmium and other substances The reliability performance and specificatio...

Страница 20: ...segment S1 Gnd 2nd mate S2 A Differential signal pair A from Phy S3 A S4 Gnd 2nd mate S5 B Differential signal pair B from Phy S6 B S7 Gnd 2nd mate Key and spacing separate signal and power segments...

Страница 21: ...io Video and Similar Electronic Apparatus CE Compliance for Europe Verified to comply with EN55022 2006 for RF Emissions and EN55024 1998 A1 2001 A2 2003 EN61000 3 2 2000 EN61000 3 3 1995 A1 2001 for...

Страница 22: ...RPS System on Chip SOC S M A R T Command Transport SCT Reliability Features Set Data Lifeguard Hot Plug Support Active LED Status Fluid Dynamic Bearings FDB Staggered Spin Up and Activity Indication...

Страница 23: ...of each data bit is aligned vertically to the spinning disk rather than longitudinally as has been the case in hard drive technology for decades In longitudinal recording as the bits become smaller a...

Страница 24: ...ion Figure 3 1 RPS Spinup Profile Note Current is 200 mA per 10 mV vertical deflection 3 4 System on Chip SOC The System on Chip SOC is the foundation for WD s next generation electronics and firmware...

Страница 25: ...n monitor the progress of the Write Same by issuing SCT Status requests This frees the host system to do other tasks while the media is being cleared 3 5 2 Read Write Long The function performed by th...

Страница 26: ...free and low level formatted at the factory After prolonged use any drive including a WD drive may develop defects If you continue receiving data errors in any given file use the Data Lifeguard Diagno...

Страница 27: ...e drive Conveyance Test Quickly identifies issues caused by handling damage Selective Test Scans host defined sections of the drive The test may be run to completion or be performed as a background ta...

Страница 28: ...Extended Read Retry Procedure ECC On the Fly If an ECC error occurs the drive attempts to correct it on the fly without retries Data can be corrected in this manner without performance penalty The de...

Страница 29: ...ugging disk drives They are hot plug controller IC s and precharge resistors 3 7 1 1 1 Hot Plug Controller IC s Hot plug controller IC s ramp up voltages to the inserted disk drive at a controlled slo...

Страница 30: ...rtion velocity with SATA specification insertion velocity analysis 3 7 1 4 1 Calculated Velocity The minimum SATA mating connector staggered pin spacing is 0 35 millimeters Disk drives typically have...

Страница 31: ...urrent and voltages low during discharge Because of the unpredictable nature of ESD use of ESD resistive not metal insertion guides is a safer solution since it gradually discharges any static charge...

Страница 32: ...ice status and activity The signal provided by the device for activity indication is a low voltage low current signal It is not suitable for directly driving an LED A buffer circuit external to the de...

Страница 33: ...e command when a host resident disk inactivity timer expires The Standby Immediate command causes the drive to spin down and enter a low power mode Subsequent disk access commands would cause the driv...

Страница 34: ...aster Password Revision code value of 0001h 00FEh must be used A Master Password Identifier of 0000h is ignored When the master password is set the drive does not enable the device lock function When...

Страница 35: ...FY B1 DEVICE CONFIGURATION RESTORE B1 DEVICE CONFIGURATION SET B1 DOWNLOAD MICROCODE 92 EXECUTE DEVICE DIAGNOSTIC 90 FLUSH CACHE E7 FLUSH CACHE EXT EA IDENTIFY DEVICE EC IDLE E3 IDLE IMMEDIATE E1 NOP...

Страница 36: ...mmand Opcodes 4 1 3 Obsolete Commands Table 4 3 lists the hexadecimal codes specific to each obsolete command supported by these hard drives Table 4 3 Obsolete Command Opcodes STANDBY E2 STANDBY IMMED...

Страница 37: ...s several sub commands that are selectable via the Features Register when the host issues the S M A R T command To select a sub command the host must write the appropriate sub command code to the Feat...

Страница 38: ...be caused by handling 09 0Eh Reserved 0Fh Self test routine in progress 364 365 XX Total time in seconds to complete offline data collection activity 366 XX Reserved 367 7Bh Offline data collection c...

Страница 39: ...Attribute ID Number Pre Failure Advisory Bit Status Flags bit 0 1 Read Error Rate 1 Pre Failure Spin up Time 3 Pre Failure Start Stop Count 4 Advisory Re allocated Sector Count 5 Pre Failure Seek Erro...

Страница 40: ...pending offline data collection process begins If an in process automatic offline data collection process is interrupted by a host command the automatic offline data collection process will then resu...

Страница 41: ...NTIFY PACKET DEVICE command Bit 13 1 Standby timer values as specified in this standard are supported 0 Standby timer values shall be managed by the device Bit 12 Reserved for the IDENTIFY PACKET DEVI...

Страница 42: ...ative Command Queuing NCQ Bit 7 3 Reserved for future Serial ATA signaling speed grades Bit 2 1 Supports Serial ATA Gen2 signaling speed 3 Gb s Bit 1 1 Supports Serial ATA Gen1 signaling speed 1 5 Gb...

Страница 43: ...f set Read Write DMA Queued supported Bit 0 If set Download Microcode command supported 0111 1101 0000 1001b 84 Command and Feature sets supported Bit 15 Shall be cleared to zero Bit 14 Shall be set t...

Страница 44: ...iple FUA EXT commands supported Bit 5 If set General Purpose Logging Feature Set supported Bit 4 Obsolete Bit 3 If set Media Card Pass Through Command feature set supported Bit 2 If set Media serial n...

Страница 45: ...2 If set WRITE UNCORRECTABLE EXT is supported Bit1 If set Write Read Verify feature set is enabled Bit 0 Reserved 0100 0000 0001 1000b 121 126 Reserved 0 127 Obsolete 0 128 Security Status Bit 15 9 R...

Страница 46: ...performance 80h Minimum power consumption without standby Disable Advanced Power Management 85h Don t care Enable use of Serial ATA Feature 10h 02h DMA Setup FIS Auto Activate optimization 03h Device...

Страница 47: ...ESD problems wear a properly grounded wrist strap when handling the hard drive Articles of clothing generate static electricity Do not allow clothing to come in direct contact with the hard drive or...

Страница 48: ...void contact with any component on the printed circuit board Figure 5 2 Hard Drive Removal From Static Shielding Bag After attaching your wrist strap gently remove the drive from the static shielding...

Страница 49: ...Z axis depending upon the physical design of your system For best results mount the drive with all four screws grounded to the chassis If all four screws are not used see Grounding on page 42 5 2 2 S...

Страница 50: ...A B C and D below You must ground the drive with at least one mounting screw Figure 5 3 Grounding Diagram Side Mounting Use four metal screws in A B C and D If less than four screws are used remove i...

Страница 51: ...umper Settings It is not necessary to put a jumper shunt on the drive for notebook use Advanced settings for the drive are as follows SSC Mode Spread spectrum clocking feature Default setting is disab...

Страница 52: ...tions Do not touch the components on the printed circuit board Do not obstruct or cover any holes on the drive s cover Air must be able to pass through these holes to the external air filter for norma...

Страница 53: ...ide variety of technical support services on our Internet site at support wdc com NORTH AMERICA US Canada Central Time 800 ASK 4WDC Monday Thursday 9 00 am 7 00 pm Friday 9 00 am 5 00 pm Saturday 8 00...

Страница 54: ...he media ECC On the Fly A hardware correction technique that corrects errors in the read buffer prior to host transfer without any performance penalties These error corrections are invisible to the ho...

Страница 55: ...encies Disk RPM is a critical component of hard drive performance because it directly impacts the rotational latency of the disk transfer rate Serial ATA SATA SATA is the next generation bus interface...

Страница 56: ...R T 28 Set Features 38 Hot Plug Support 20 I Input Voltage Requirements 8 Installation and Setup 39 Interleave 3 Internal Environmental Protection System 18 J Jumper Settings 42 Jumper Settings Diagr...

Страница 57: ...taggered Spinup 23 System on Chip SOC 15 T Technical Support 44 Online Services 44 Temperature airflow 10 cooling 10 thermocouple location 9 Temperature and Humidity 9 Thermal Management 17 Thermocoup...

Страница 58: ...50 RELEASED 4 7 11 WD CONFIDENTIAL 2679 771320 A00 Index WD Scorpio ML320S AF2...

Страница 59: ...1320 A00 Apr 2011 800 ASK 4WDC North America 800 832 4778 Spanish 800 6008 6008 Asia Pacific 00800 27549338 Europe toll free where available 31 880062100 Europe Middle East Africa Western Digital 3355...

Отзывы: