7
6644-2240
Type tests and environmental conditions
Environmental phenomena Basic standard Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
±2 kV
Signal ports
±2 kV
Surge
EN 61000-4-5
Power port
Line to earth: ±2 kV
Line to line: ±1 kV
Signal ports
Line to earth: ±2 kV
Line to line: ±1 kV
Power frequency magnetic field EN 61000-4-8
Enclosure
300 A/m; 0, 16.7, 50 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF immunity
EN 61000-4-3
Enclosure
20 V/m @ (80 – 2700) MHz
10 V/m @ (2700 – 6000) MHz
1 kHz sine, 80% AM
Conducted RF immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Signal ports
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission
CISPR 16-2-3
Enclosure
Class B (30 – 6000 MHz)
ANSI C63,4
(FCC Part 15)
Class B (30 – 6500 MHz)
Conducted RF emission
CISPR 16-2-1
Power port
Class B
Signal ports
Class B
Dielectric strength
EN 60950-1
Power interface to all other 1.5kV AC @ 60s duration
TX signal interface to all other 1.5kV AC @ 60s duration
TX shield interface to all other 1.5kV AC @ 60s duration
Environmental
Temperatures
EN 60068-2-1
EN 60068-2-2
Operating
–40 to +74 °C (–40 to +165 °F)
Storage and transport
–50 to +85 °C (–58 to +185 °F)
Relative humidity
EN 60068-2-30
Operating
5 to 95 % (non-condensing)
Storage and transport
5 to 95 % (condensation allowed
outside packaging)
Altitude
Operating
2 000 m/70 kPa
Service life
Operating
10 year
Reliability prediction (MTBF)
MIL-HDBK-217F
Operating
SDW-541-F1G-T4G: 1.182.000 hours
SDW-550-T5G: 1.121.000 hours
Vibration
IEC 60068-2-6
(sine)
Operating
5–9 Hz ±6 mm
9–500 Hz ±2 g
Shock
IEC 60068-2-27
Operating
15 g, 11 ms
Mechanical
Enclosure
UL94
Plastic
Flammability Class V-0
Dimension W x H x D
34 x 123 x 121 mm
Weight
0.2 kg
Mounting
DIN-rail
Degree of protection
EN 60529
Enclosure
IP21
Cooling
Convection
Configuration
Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches. Port
mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing
traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total
throughput exceeds the port speed of port 1.