DIP switch settings SDW-541 and SDW-532
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to
configure the unit.
Warning!
Prevent damage to internal electronics from electrostatic discharges (ESD) by
discharging your body to a grounding point (e.g. use of wrist strap), before the lid
on top/front of the unit is removed.
Warning! Do not open connected equipment.
Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains
supply and all other electrical connections.
!
!
NOTE
When configuration via DIP-switches, the settings of DIP-switches configure the unit only
after a reboot (power off/on).
To be observe when the DIP-switches will be configured
… Speed and duplex setting only valid when auto-negotiation is disabled.
… When monitoring selected all outgoing packets from the switch is also copied to the
port 1.
… Speed and duplex switch settings are ignored for FX ports.
… If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
configuration.