RT-370 User Guide
Page 30 (34)
Figure 17 Service 1000Base-TX interface
The connectors should be assembled with correct torque (appr. 1.0 Nm, check connector manufacturer data).
NOTICE
: The service Ethernet Interface connector fulfills the IP-protection when the cable plug or the dust cap is
connected. If the service Ethernet function is not used in application, the protective dust cap must be closed.
Connector Pin
Signal name, Function
Notes
1
MX1 +
Connector Type: Industrial ETHERNET M12-Socket “X”-
coded
2
MX1 -
3
MX2 +
4
MX2 -
5
MX4 +
6
MX4 -
7
MX3 -
8
MX3 +
Housing
Ground
For possible cable protection/screening
Table 25 Service 1000Base-TX Connector
NOTICE: The Pinning is compliant to IONA, Industrial Ethernet Planning and Installation Guide, Release 4.0.
5.2.1 Service Ethernet Port Features
The Ethernet port supports the following network standards:
Network Standard
Description
10BASE-T
Ethernet over two pairs of twisted wires
100BASE-TX
Fast Ethernet over two pairs of twisted wires
1000BASE-TX
Gigabit Ethernet over four pairs of twisted wires
Table 26 4.6.1 Ethernet port features