background image

www.westermo.com

         

  

               

                            

OS

RedFox 7528 Series

Industrial routing switches

Содержание RedFox 7528 Series

Страница 1: ...www westermo com OS RedFox 7528 Series Industrial routing switches ...

Страница 2: ... UL 62368 1 Notice 8 2 5 4 Corrosive Environment 8 2 5 5 Simplified Declaration of Conformity 9 3 Product Description 10 3 1 Product Description 10 3 2 Available Models 10 3 3 Hardware Overview 11 3 4 Connector Information 11 3 4 1 Power Input 11 3 4 2 I O Connection 12 3 4 3 Console Port 12 3 4 4 Micro SD 12 3 4 5 SFP Transceivers 13 3 5 LED Indicators 14 3 6 Dimensions 15 4 Mounting 16 4 1 Rack ...

Страница 3: ...ers of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at https www westermo com support product support 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source So...

Страница 4: ...zardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No person...

Страница 5: ...g installation ensure a protective earthing conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last HAZARDOUS VOLTAGE Do not open an energised product Hazardous voltage may occur when connected to a pow...

Страница 6: ...on inside the optical port They are very sensitive to dust and dirt If the fibre optic cable is disconnected from the product a protective plug must be used on the transmitter receiver The protective plug must be kept on during transportation The fibre optic cable must be handled the same way CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connec...

Страница 7: ...Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring the product is disposed of correctly you will help to reduce hazardous substances and prevent potential negative consequences to both the environment and human hea...

Страница 8: ...afety for Communication Technology In accordance with the definitions of the standard this product shall be handled by instructed personnel Energy source classifications are according to following Electrical energy source Power port ES1 Serial port ES1 Ethernet port ES1 TNV 1 I O port ES1 Power source Power port PS3 Thermal energy source Enclosure TS1 Mechanical energy source Enclosure MS1 MS3 for...

Страница 9: ... is in compliance with applicable EU directives and UK legislations The full declaration of conformity and other detailed information is available at www westermo com support product support Figure 2 The European Conformity and the UK Conformity Assessment markings RedFox 7528 Series 9 ...

Страница 10: ...atures and demanding electrical environments RedFox 7528 has been tested both by Westermo and external test labs to meet many standards regarding EMC isolation vibration and shock all to the highest levels suitable for heavy industrial environments and rail trackside applications Powered by WeOS the Westermo network operating system the switches are flexible feature rich as well as easy to install...

Страница 11: ...l 6 10 100 1000 Mbit s TX ports number depending on model 7 Power input 8 Protective earth 9 SFP ports 10 Label with data matrixa aThe base MAC address and production date of the product is included in the front label data matrix Figure 3 Location of interface ports and LED indicators illustrated by a RedFox 7528 F4G10 F12G T12G LV 3 4 Connector Information 3 4 1 Power Input Illustration Product m...

Страница 12: ...rm events within the product see WeOS Management Guide An external load in series with an external DC voltage source is required for proper functionality Unit condition Status NO C Status NC C Unpowered pre operational or Alarm active OPEN CLOSED Operational and Alarm inactive CLOSED OPEN Table 5 Status output 3 4 3 Console Port The console port can be used to connect to the CLI Command Line Inter...

Страница 13: ...product support In the event of contamination the optical connectors in the SFP transceivers should only be cleaned by the use of forced nitrogen and some kind of cleaning stick Recommended cleaning fluids are methyl ethyl isopropyl or isobutyl alcohol hexane or naphtha HANDLING OF SFP TRANSCEIVERS SFP transceivers are supplied with plugs to avoid contamination inside the optical port They are ver...

Страница 14: ...led BLINK Product selected as RSTP STP root switch USR1 Configurable see WeOS5 User Guide FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error FLASH Product configured as FRNT focal point DC1 OFF Product has no power GREEN Power OK on DC1 RED Input voltage is below operating voltage limit DC2 OFF Product has no power GREEN Power OK on DC2 RED Input voltage is below operating voltage limit USR2 Conf...

Страница 15: ...nsions Dimensions are stated in mm 482 4 43 32 469 462 18 411 466 240 7 2 x4 235 440 R 3 5 7 DETAIL A SCALE 1 1 Figure 5 Dimensional drawing illustrated by a RedFox 7528 F4G10 F12G T12G LV RedFox 7528 Series 15 ...

Страница 16: ...s Use maximum 6 4 mm or 1 4 screws DC1 DC2 FRNT RSTP USR1 USR2 ON CONSOLE SD NO I O DI Status Digital in NC C DI POWER 24 48 VDC COM DC DC 1 DC 2 2 1 4 3 6 5 8 7 9 10 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 SFP SFP Figure 7 Wall mounted product 4 3 Protective Earth Connection For correct function the earth connection needs to be properly connected to a designated PE rail See the figu...

Страница 17: ...ilation a minimal spacing of 1U according to IEC 60297 or 45 mm 1 75 above below is recommended For wall mounting in an area without forced ventilation a minimum spacing of 45 mm 1 75 above below and 10 mm 0 4 left right is recommended RedFox 7528 Series 17 ...

Страница 18: ...artup current 2x nominal current Polarity Reverse polarity protected Redundant power input Yes Isolation All other ports Connector Detachable screw terminal Conductor cross section 0 5 1 5 mm AWG 20 16 Use copper conductors only Stripping length cable 7 mm Cable temperature rating Minimum temperature rating of the cable to be connected to the field wiring terminals is 77 C Tightening torque termin...

Страница 19: ...levels Logic one 8 VDC Logic zero 5 VDC I O connection Relay output Connect resistance Maximum 30 Ω Isolation to All other ports Connector Detachable screw terminal Conductor cross section 0 08 1 5 mm AWG 28 16 Use copper conductors only Stripping length cable 7 mm Cable temperature rating Minimum temperature rating of the cable to be connected to the field wiring terminals is 77 C Tightening torq...

Страница 20: ...nual or auto Transmission range Depending on transceiver Connector SFP slot holding fibre transceiver aSFP ports are 5 6 11 14 19 22 27 28 b100 Mbit s or 1000 Mbit s tranceiver supported SFP portsa Optical Electrical specification IEEE std 802 3 Data rate 1000 Mbit s 10 Gbit sb Duplex Full or half manual or auto Transmission range Depending on transceiver Connector SFP slot holding fibre transceiv...

Страница 21: ...Micro SD Electrical specification Secure Digital 2 0 Circuit type SELV Maximum supply current 100 mA Connector Micro SD connector RedFox 7528 Series 21 ...

Страница 22: ...C Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m at 80 MHz to 2 7 GHz 10 V m at 2 7 to 6 GHz Conducted RF immunity EN 61000 4 6 Power port Ethernet ports I O ports Earth port 10 V 80 AM 1 kHz 0 15 80 MHz Radiated RF emission CISPR 16 2 3 Enclosure Class A 30 6000 MHz ANSI C63 4 Class A FCC Part 15 B 30 MHz to 26 GHz Conducted RF emission CIS...

Страница 23: ...m 80 kPa MTBF hours MIL HDBK 217F 371 000 hours Telcordia 763 000 hours Vibration IEC 60068 2 6 sine Operational 5 8 Hz 7 5 mm 8 500 Hz 2 g 5 sweeps per axis IEC 60068 2 64 random Operational endurance test 5 2000 Hz 2 3 m s2 rms 90 minutes per axis Shock IEC 60068 2 27 Operational 15 g 11 ms Enclosure EN IEC UL 62368 1 Aluminium Fire enclosure Weight 3 8 kg Degree of protection EN 60529 Enclosure...

Страница 24: ...6 Revision Notes Revision Date Change description Rev A 2022 05 First version of the user guide 24 RedFox 7528 Series ...

Страница 25: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6641 26001 REV A 2022 05 Westermo Network Technologies AB Sweden ...