Содержание RedFox 5528 Series

Страница 1: ...www westermo com WeOS RedFox 5528 Series Industrial routing switches ...

Страница 2: ...rds Compliance 8 2 8 2 FCC Part 15 105 Notice 8 2 8 3 Corrosive Environment 8 2 8 4 Simplified Declaration of Conformity 9 3 Product Description 10 3 1 Product Description 10 3 2 Available Models 10 3 3 Hardware Overview 11 3 4 Connector Information 11 3 4 1 Power Input and I O 11 3 4 2 I O Connection 12 3 4 3 Console Port 13 3 4 4 SFP Transceivers 13 3 5 LED Indicators 14 3 6 Dimensions 15 4 Inst...

Страница 3: ...Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source Software FLOSS The s...

Страница 4: ...zardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No person...

Страница 5: ...rom all power supply Ensure compliance to national installation regulations This product relies on convection cooling To avoid obstruction of the airflow around the product follow the spacing recommendations See Cooling chapter WARNING PROTECTIVE EARTHING Before powering up a protective earthing conductor must be connected to the protective earthing terminal and have a cross sectional area of at l...

Страница 6: ...optical port or any connected fibre although the product is designed to meet the Class 1 Laser regulations and complies with 21 CFR 1040 10 and 1040 11 CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated connector pins NOTICE REDUCE RIS...

Страница 7: ...otective hood must be kept on during transportation The fibre optics cable must also be handle the same way If these recommendations are not followed the warranty might be at risk 2 6 Cleaning Optical Connectors In the event of contamination the optical connectors should only be cleansed with recommended cleaning fluids and correct cleaning equipment Recommended cleaning fluids Methyl ethyl isopro...

Страница 8: ...communications However there is no guarantee that interference will not occur in a particular installation If this product does cause harmful interference to radio or television reception which can be determined by turning the product off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the...

Страница 9: ...declares that this product is in compliance with applicable EU directives The full EU declaration of conformity and other detailed information is available at www westermo com support product support Figure 2 The European conformity marking RedFox 5528 Series 9 ...

Страница 10: ...ts or cooling holes in the case RedFox has been tested both by Westermo and external test labs to meet many standards regarding EMC isolation climate vibration and shock all to the highest levels suitable for heavy industrial environments and rail trackside application WeOS has been developed to allow offer cross platform and future proof solutions WeOS can deliver 20 ms ring recovery performance ...

Страница 11: ...o SD 5 100 1000 Mbit s SFP slots number depending on model 6 10 100 1000 Mbit s TX ports number depending on model 7 Power Input 8 Protective earth Figure 3 Location of interface ports and LED indicators illustrated by a RedFox 5528 F16G T12G 3 4 Connector Information 3 4 1 Power Input and I O Illustration Position Product marking Direction Description 1 2 3 4 1 DC1 Input Supply voltage 2 DC2 Inpu...

Страница 12: ...n Pin no Product marking Direction Description 1 2 3 4 Digital in Digital in NO NC C Status 5 1 Digital in Input Digital in 2 Digital in Digital in 3 Status NO Output Alarm status relay contact 4 Status C 5 Status NC Table 4 I O connection The Digital in is an opto isolated digital input which can be used to monitor external events The Status output is a potential free opto isolated alternation Fo...

Страница 13: ...ommand Line Interface The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally For drivers refer to www ftdichip com and download the appropriate VCP driver 3 4 4 SFP Transceivers The product supports Westermo labelled transceivers only See Westermo s modular transceivers datasheets 100 Mbit and 1 Gbit for supported SFP transceivers for the RedFo...

Страница 14: ...NK Product selected as RSTP STP root switch USR1 Configurable see WeOS Management Guide FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Product configured as FRNT focal point DC1 OFF Product has no power GREEN Power OK on DC1 RED DC1 input voltage is below operating voltage limit DC2 OFF Product has no power GREEN Power OK on DC2 RED DC2 input voltage is below operating voltage limit USR...

Страница 15: ...e stated in mm 32 480 462 469 43 Grounding Point Screw M5 x 0 8 mm Roll tap true all 235 466 18 240 7 2 4x 440 411 4 7 DETAIL A SCALE 1 1 Figure 5 Dimensional drawing Illustrated by RedFox 5528 F4G T24G HV LV RedFox 5528 Series 15 ...

Страница 16: ... Mounting The product can be mounted in all directions inside a 19 apparatus cabinet Use M6x25 or 1 4x1 CONSOLE Digital in Digital in NO C NC Stat us I O ON DC1 DC2 FRNT RSTP USR1 USR2 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 28 27 26 25 DC 1 DC 2 COM COM PO WE R Figure 6 Rack mounted product 4 1 2 Wall Mounting The product can be wall mounted in all directions Use maximum 6 ...

Страница 17: ... 22 23 24 25 26 27 28 DC1 DC2 COM COM POWER I O Figure 8 Earth connection 4 3 Cooling For mounting in 19 apparatus cabinet without forced ventilation a minimal spacing of 1U according to IEC 60297 or 45 mm 1 75 above below is recommended With forced ventilation no minimal spacing is required as long as the temperature of the rear cooling plates does not exceed 85ºC 185ºF For wall mounting in an ar...

Страница 18: ...t 110 VDC RedFox 5528 E F16G T12G LV 1 30 A at 24 VDC 0 64 A at 48 VDC RedFox 5528 E F16G T12G HV 0 65 A at 48 VDC 0 28 A at 110 VDC Fuse rating Component U2 LV U1 HV All modelsa 4A T Rated frequency DC Inrush current I t For all LV models 125 mA2s at 24 VDC 82 mA2s at 48 VDC For all HV models 34 mA2s at 48 VDC 33 mA2s at 110 VDC Startup currentb 2x nominal current Polarity Reverse polarity protec...

Страница 19: ...g torque terminal screw 0 22 0 25 Nm Terminal torque screw flange 0 3 Nm Maximum voltage current 60 VDC IIN 2 9 mA at 60 VDC Voltage levels Logic one 8 VDC Logic zero 5 VDC I O connection Relay output Connect resistance Maximum 30 Ω Isolation to All other ports Connector Detachable screw terminal Conductor cross section 0 14 1 5 mm AWG 28 16 Stripping length cable 7 mm Tightening torque terminal s...

Страница 20: ...ctrical specification IEEE std 802 3 Data rate 100 Mbit s 1000 Mbit sb Duplex Full or half manual or auto Transmission range Depending on transceiver Connector SFP slot holding fibre transceiver aSFP ports are RedFox 5528 E F4G T24G LV and HV 1 4 RedFox 5528 E F16G T12G LV and HV 1 6 11 14 19 22 27 28 b100 Mbit s or 1000 Mbit s tranceiver supported Console port Electrical specification USB 2 0 dev...

Страница 21: ...ulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m at 80 MHz to 2 GHz 10 V m at 2 6 GHz 1 kHz sine 80 AM Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet ports Earth port I O port Radiated RF emission CISPR 16 2 3 Enclosure Residential 30 6000 MHz ANSI C63 4 FCC Part 15 B Class B 30 MHz 25 5 GHz Conducted RF emi...

Страница 22: ...0 hours RedFox 5528 F16G T12G LV 386 000 hours RedFox 5528 T28G HV 366 000 hours RedFox 5528 T28G LV 356 000 hours Telcordia RedFox 5528 F4G T24G HV 667 000 hours RedFox 5528 F4G T24G LV 643 000 hours RedFox 5528 F16G T12G HV 735 000 hours RedFox 5528 F16G T12G LV 706 000 hours RedFox 5528 T28G HV 643 000 hours RedFox 5528 T28G LV 620 000 hours Vibration IEC 60068 2 6 sine Operational 2 g rms 5 50...

Страница 23: ... Cooling Convection aRefer to Safety and Regulations chapter regarding touch temperature bMethod 3 21 days corresponds to Harsh Industrial Environment G3 which is defined in ANSI ISA 17 04 2015 Table 8 Environmental and mechanical conditions RedFox 5528 Series 23 ...

Страница 24: ...s updated 5 1 Interface specifications updated 5 2 Type test and environmental conditions updated Rev C 2018 10 2 2 New warning added 2 7 Environmental protection updated to Product disposal 2 8 1 Agency approvals updated 2 8 3 Corrosive gases upgraded to Caution instead of Notice 2 8 4 DoC updated 3 1 Text updated 3 4 1 Warning updated with illustrations 3 4 4 Figure 3 deleted old 5 1 Fuse rating...

Страница 25: ...RedFox 5528 Series ...

Страница 26: ...RedFox 5528 Series ...

Страница 27: ...RedFox 5528 Series ...

Страница 28: ...Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6641 22820 REV D 2019 06 Westermo Network Technologies AB Sweden ...