background image

6

6621-2260

Environmental conditions

Phenomena

Test

Description

Test levels

Temperature

Operating

–20 to +55ºC

Storage & Transport

–40 to +85C

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

Up to 2 000 m / 70 kPa

Enclosure

UL 94

Zink

Flammability class V-1

Dimension W x H x D

52.5 x 100 x 101 mm

Weight

0.6 kg

Degree of protection

IEC 529

Enclosure

IP 40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail

Type tests immunity

Environmental  
Phenomena

Basic  
Standard

Level

Electrostatic discharge  
Test

EN 61000-4-2

6kV/8kV (contact/air) 
Performance Criteria B

RF field AM modulated

EN 61000-4-3

20V/m 80–2700 MHz 
Performance Criteria A

Electrical fast transient 
Burst

EN 61000-4-4

±4.0 kV (power ports) 
±4.0kV (signal ports) 
Performance Criteria A

Surge

EN 61000-4-5

±4.0 kV (L-E power) 
±2.0 kV (L-L power) 
±2.0 kV (L-E signal) 
±1.0 kV (L-L signal) 
Performance Criteria B

RF conducted

EN 61000-4-6

10V/m 0,15 to 80MHz 
(power & signal port) 
Performance Criteria A

Power frequency 
(50 Hz) magnetic field

EN 61000-4-8

300 A/m

Slow damped oscillatory wave 
immunity test, 1 MHz burst

EN 61000-4-18

2.5 kV (CM)1.0 kV (DM)

Power frequency immunity test

IEC 60255-22-7

Voltage dips, short interruptions 
and voltage variations on d.c. 
input power port immunity tests

EN 61000-4-29 
(DC port)

Dips:  
30 %, 60% 
10, 30, 50, 100, 300, 1000 ms 
Interruptions:  
1, 3, 10, 30, 50, 100, 300, 1000, 5000 ms
Variations: 
80%, 120%, 10 s 
Performance Criteria A < 50ms 
Performance Criteria B > 50ms

Содержание Pilot Wire RPW600F

Страница 1: ...Pilotwire modem RPW600M RPW600F User Guide 6621 2260...

Страница 2: ...of merchantability and fitness for a particular purpose are made in relation to the accuracy and reliability or contents of this document The manufacturer reserves the right to revise this document o...

Страница 3: ...us voltage may occur within this unit when connected to power supply Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligation...

Страница 4: ...The fibre optic cable must also be handled the same way If this recommendation not will be followed it can jeopardise the warranty Cleaning of the optical connectors In the event of contamination the...

Страница 5: ...o enable ease of use no setting or configuration is needed with either of the RPW600 modem variants Pilot wire link lengths typically up to 8 km with 0 8 mm2 twisted pair cables can be applied With tw...

Страница 6: ...ted EN 61000 4 3 20V m 80 2700 MHz Performance Criteria A Electrical fast transient Burst EN 61000 4 4 4 0 kV power ports 4 0kV signal ports Performance Criteria A Surge EN 61000 4 5 4 0 kV L E power...

Страница 7: ...6 Test Fc 10 150 Hz 0 075 mm 10 58 Hz 10m s 58 150 Hz 1 sweep cycles in each of the three directions Vibration endurance test IEC 60068 2 6 Test Fc 10 150 Hz 20m s 58 150 Hz 20 sweep cycles in each o...

Страница 8: ...Not required External supply current capability for proper startup Pilot Wire Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 12 Shielded cable Not requir...

Страница 9: ...tions Pilot wire Position Direction Description 1 In Out 2 wire Receive Transmit 2 In Out 2 wire Receive Transmit Direction relative this unit Console see more information on page 8 LED indicators see...

Страница 10: ...a is transmitted PW Pilot wire link indication OFF Inactive link GREEN Active link GREEN FLASH Link negotiation QoS Quality of service pilot wire link quality indication LED 1 LED 2 LED 3 1 2 3 GREEN...

Страница 11: ...agnostic parameters Connection to the RPW unit is possible via the console port in the front of the unit using the serial con sole cable also part of the diagnostic kit The following steps needs to be...

Страница 12: ...Removal Press down the support at the back of the unit using a screwdriver See figure Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spaci...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...REV A 6621 2260 2010 07 Made for ABB by Westermo Teleindustri AB ABB Oy Distribution Automation P O Box 699 FI 65101 VAASA Finland Phone 358 10 22 11 Fax 358 10 22 41094...

Отзывы: