18

6651-2231

S2 DIP-switch

ON 

 1  2  3 4  5 6  7 8

CTS always active.

ON 

 1  2  3 4  5 6  7 8

Use secondary data channel.*

ON 

 1  2  3 4  5 6  7 8

Transport RTS to CTS.*

ON 

 1  2  3 4  5 6  7 8

Single channel system redundant 
ring. E.g. only the primary or  
secondary channel is used.

ON 

 1  2  3 4  5 6  7 8

Multidrop mode.

ON 

 1  2  3 4  5 6  7 8

Dual channel system redundant ring. 
E.g. both the primary and secondary 
channel are used simultaneously.

ON 

 1  2  3 4  5 6  7 8

Redundant ring mode.

ON 

 1  2  3 4  5 6  7 8

Set status port on both local fibre 
link (FL L) and remote fibre link  
(FL R) errors.

ON 

 1  2  3 4  5 6  7 8

Multidrop mid unit or 
Redundant ring member.

ON 

 1  2  3 4  5 6  7 8

Set status port on local fibre link 
(FL L) error only.

ON 

 1  2  3 4  5 6  7 8

Multidrop end unit. Redundant ring 
focal point.

ON 

 1  2  3 4  5 6  7 8

S2:7 has no function

ON 

 1  2  3 4  5 6  7 8

Use primary data channel.

ON 

 1  2  3 4  5 6  7 8

Always OFF

*   = RTS to CTS transport and secondary channel cannot be used at the same time.

Factory default

ON 

 1  2  3 4  5 6  7 8

S1

ON 

 1  2  3 4  5 6  7 8

S2

Содержание ODW-720-F2

Страница 1: ...Westermo Teleindustri AB www westermo com User Guide 6651 2231 Industrial Converter RS 232 to Fibre Optic Link Repeater line and redundant ring ODW 720 F2 Fibre Optic Modem...

Страница 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Страница 3: ...nected to a power supply Class 1 Laser Product This unit is designed to meet the Class 1 Laser regulations However the user is warned not to look directly into fibre optical fibre port or any connecte...

Страница 4: ...le protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used...

Страница 5: ...cerning explosive atmospheres caused by gases vapours or mists G Ex Indicates that this unit is in conformity with relevant European Ex standard s nA Type of protection used This unit is a non sparkin...

Страница 6: ...uest To Send RTS 8 Out Clear To Send CTS 9 Not connected Position Descripton Output values Rx In Receive port Max 0 dBm Tx Out Transmit port Position Descripton Input values 1 In Common Uin 10 60 VDC...

Страница 7: ...it is protected from light for example daylight or light from luminaires See Installation in an apparatus cabinet above for requirements on the external apparatus cabinet Secureness of plugs When this...

Страница 8: ...Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity industrial environments 2005 EN 61000 6 3 Electromagn...

Страница 9: ...ltage Mains freq 50 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radiated emission EN 55022 Enclosure Class B FCC part 15...

Страница 10: ...between electrical RS 232 and a fibre optical link ODW 720 can also be used to convert from RS 232 to RS 485 by using a ODW 720 in the same link as ODW 730 Repeater optical fibre links ODW 720 is a f...

Страница 11: ...larity protected Redundant power input Yes Isolation to RS 232 and Status port Connection Detachable screw terminal Connector size 0 75 2 5 mm2 AWG 18 13 Connect the unit using at least 18 AWG 0 75 mm...

Страница 12: ...system of an installation and may be directly connected to the protective earth Optical Power Budget The allowed link length is calculated from the optical power budget OPB the available optical power...

Страница 13: ...310 Tx1310 Rx 1550 Tx 1550 Rx 1310 Transmitter Output optical power min max 8 0 dBm 14 8 dBm Receiver Input sensitivity max 34 dBm 32 dBm Receiver Input optical power max 3 dBm 0 dBm Optical power bud...

Страница 14: ...D 3 In Transmitted Data TD 4 Not connected 5 Signal Ground SG 6 Out Data Set Ready DSR 7 In Request To Send RTS 8 Out Clear To Send CTS 9 Not connected RS 232 D sub Status screw terminal Position Desc...

Страница 15: ...ablished at CH 1 OFF No optical power detected and no link to other unit has been established at CH 1 TD Flash Data received on the electrical interface and transmitted out on the optical inter face O...

Страница 16: ...ON 1 2 3 4 5 6 7 8 1200 bit s ON 1 2 3 4 5 6 7 8 57 6 kbit s ON 1 2 3 4 5 6 7 8 9 bits data format ON 1 2 3 4 5 6 7 8 2400 bit s ON 1 2 3 4 5 6 7 8 115 2 kbit s ON 1 2 3 4 5 6 7 8 10 bits data format...

Страница 17: ...s ON 1 2 3 4 5 6 7 8 4 s S1 DIP switch Description V Y mode ON 1 2 3 4 5 6 7 8 Y mode ON 1 2 3 4 5 6 7 8 V mode OR OR OR channel 1 channel 2 RS 232 If both fibre channels 1 and 2 are used and not red...

Страница 18: ...multaneously ON 1 2 3 4 5 6 7 8 Redundant ring mode ON 1 2 3 4 5 6 7 8 Set status port on both local fibre link FL L and remote fibre link FL R errors ON 1 2 3 4 5 6 7 8 Multidrop mid unit or Redundan...

Страница 19: ...lay witch may be used to trigger an external alarm if a fault condition occurs During normal operation pins 1 and 2 are in contact with each other and pins 2 and 3 are isolated During an optical link...

Страница 20: ...cing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be mounted...

Страница 21: ...Referring documents For detailed information on how to configure the ODW 720 F2 for different applications Type Description Document number Management Guide Management Guide ODW 720 F2 6651 2235...

Страница 22: ......

Страница 23: ......

Страница 24: ...o com France infos westermo fr www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sv...

Отзывы: