background image

5

6651-2221

Before installation:

Read this manual completely and gather all information on the product. Make sure that 
you understand it fully. Check that your application does not exceed the safe operating 
specifications for this product. 

WARNING - SAFETY DURING INSTALLATION

 The product must be installed by qualified service personnel 
and built in to an apparatus cabinet or similar, where access is 
restricted to service personnel only.

WARNING - HAZARDOUS VOLTAGE

Do not open an energized product. Hazardous voltage may occur 
when connected to a power supply. 

WARNING - PROTECTIVE FUSE

It must be possible to disconnect manually from the power supply. 
Ensure compliance to national installation regulations. Replacing 
the internal fuse must only be performed by Westermo qualified 
personell.

CAUTION - CLASS 1 LASER PRODUCT

Do not look directly into a fibre optical port or any connected 
fibre, although the product is designed to meet the Class 1 Laser 
regulations and complies with 21 CFR 1040.10 and 1040.11.

CAUTION - ELECTROSTATIC DISCHARGE (ESD) 

Prevent electrostatic discharge damages to internal electronic 
parts by discharging your body to a grounding point (e.g. use a 
wrist strap).

Содержание ODW-720-F1

Страница 1: ...www westermo com ODW 720 F1 Fibre Optic Modem Industrial Converter RS 232 to Fibre Optic Link Point to Point applications...

Страница 2: ...2 6651 2221...

Страница 3: ...essed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Westermo reserves the right to revise this document or withdraw it at any t...

Страница 4: ...potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product...

Страница 5: ...product Hazardous voltage may occur when connected to a power supply WARNING PROTECTIVE FUSE It must be possible to disconnect manually from the power supply Ensure compliance to national installation...

Страница 6: ...pal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring this product is disposed of correctly you will...

Страница 7: ...n which case the user will be required to correct the interference at his own expense Agency approvals and standards compliance Type Approval Compliance EMC EN 61000 6 1 Immunity residential environme...

Страница 8: ...freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radiated emission CISPR 16 2 3 Enclosure EN 61000 6 3 ANSI C63 4 FCC part 15 Conducted emission CISPR 16 2 1 AC power ports EN 61000 6 3...

Страница 9: ...al RS 232 and a fibre optic link ODW 720 F1 can also be used to convert from RS 232 to RS 485 by using one ODW 720 F1 and one ODW 730 F1 Data rate up to 250 kbit s ODW 720 F1 converts data using rates...

Страница 10: ...unit using at least 18 AWG 0 75 mm2 wiring Shielded cable Not required External supply current capability for proper startup Status Port type Signal relay changeover contacts Rated voltage Up to 48 VD...

Страница 11: ...aratus and located close to rails Conductive housing Isolated to all other circuits and housings To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3...

Страница 12: ...O 2 Common C 3 Open no contact with C when fibre optical links are in operation NC Position Direction Description Product marking 1 In Common voltage COM 2 In Voltage A VA 3 In Voltage B VB 4 In Commo...

Страница 13: ...ical inter face OFF No data received on the electrical inter face RD Flash Data received on the optical interface and transmitted out on the electrical interface OFF No data received on the optical in...

Страница 14: ...with ODW 720 F2 units please refer to the ODW 720 F2 user guide for details on how to configure the units S1 DIP switch ON 1 2 3 4 5 6 7 8 S1 1 S1 8 always OFF for point to point applications S2 DIP s...

Страница 15: ...es from PLC master that are correctly received the ODW 720 F1 should be indicated by flashing TD LED Frames that are received via the fibre link will be transmitted to the PLC slave and indicated by f...

Страница 16: ...ent fibre transceivers and connectors can be used RS 232 interface The RS 232 interface is a female 9 position D sub Pin assignments are compliance with the EIA RS 232 standard Status port The status...

Страница 17: ...cing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be mounted...

Страница 18: ...REV J 6651 2221 2021 05 Westermo Network Technologies AB Sweden Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Отзывы: