6651-22641

Electromagnetic Compatibility

Phenomena

Test

Description

Level

ESD

EN 61000-4-2

Enclosure contact 

± 6 kV

Enclosure air

± 8 kV

RF field AM modulated 

IEC 61000-4-3

Enclosure

10 V/m 80% AM (1 kHz), 80 – 800 MHz
20 V/m 80% AM (1 kHz), 800 – 1000 MHz
20 V/m 80% AM (1 kHz), 1400 – 2700 MHz

RF field 900 MHz

ENV 50204

Enclosure

20 V/m pulse modulated 200 Hz, 900 ± 5 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports unbalanced

± 2 kV line to earth, ± 2 kV line to line 

Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Pulse Magnetic field

EN 61000-4-9

Enclosure

300 A/m, 6.4 / 16 µs pulse

Voltage dips  
and interruption

EN 61000-4-11

AC power ports

10 & 5 000 ms, interruption
200 ms, 40% residual voltage
500 ms, 70% residual voltage

Mains freq. 50 Hz

EN 61000-4-16

Signal ports

100 V 50 Hz line to earth

Mains freq. 50 Hz

SS 436 15 03

Signal ports

250 V 50 Hz line to line

Radiated emission 

EN 55022

Enclosure

Class B

FCC part 15

Class A

Conducted emission

EN 55022

AC power ports

Class B

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class A

Dielectric strength

EN 60950

Signal port to all other 
isolated ports

2 kVrms 50 Hz 1min

Power port to other 
isolated ports

3 kVrms 50 Hz 1min 
2 kVrms 50 Hz 1min (@ rated power < 60V)

Environmental

Temperature

Operating

–40 to +70°C

Storage & Transport

–40 to +70°C

Maximum surface  
temperature

135ºC (temperature class T4)

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz  
2 g, 8 – 500 Hz

Shock

IEC 60068-2-27

Operating

15 g, 11 ms

Packaging

Enclosure

UL 94

PC / ABS

Flammability class V-1

Dimension W x H x D

35 x 121 x 119 mm

Weight

0.26 kg

Degree of protection

IP 21

Cooling

IEC 529

Enclosure

Convection

Mounting

Horizontal on 35 mm DIN-rail

Type tests and environmental conditions

Содержание ODW-630-F1

Страница 1: ...www westermo com ODW 630 F1 Fibre Optic Modem Industrial Converter Serial RS 485 to Fibre Optic Link Point to Point applications...

Страница 2: ...2 6651 22641...

Страница 3: ...s for a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prio...

Страница 4: ...regulations However the user is warned not to look directly into fibre optical port or any connected fibre Care recommendations Follow the care recommendations below to maintain full operation of the...

Страница 5: ...s should be cleaned by using forced nitrogen and some kind of cleaning stick Recommended cleaning fluids Methyl ethyl isopropyl or isobutyl alcohol Hexane Naphtha Maintenance No maintenance is require...

Страница 6: ...r will be required to correct the interference at his own expense Type Approval Compliance EMC EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 3...

Страница 7: ...q 50 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radiated emission EN 55022 Enclosure Class B FCC part 15 Class A Conduc...

Страница 8: ...on OVP Over Voltage Protection OCP Over Current Protection Converter serial interface optical fibre ODW 630 F1 is a fibre optic modem that converts between electrical RS 485 and a fibre optic link ODW...

Страница 9: ...COM VA VB COM TX RX TX RX Fibre optical connection at point to point communication POWER CH 1 COM VA VB COM POWER CH 1 COM VA VB COM TX RX TX RX Fibre optical connection at point to point communicatio...

Страница 10: ...dundant power supply galvanic isolated 2 kVAC to other ports The ODW 630 F1 should be supplied with safety extra low voltage SELV It is designed to operate permanently over a wide DC or AC voltage inp...

Страница 11: ...ng 1 Fibre The optical fibre length delay 2 Converter electrical to fibre Signal processing delay 3 Converter fibre to electrical Signal processing delay Example 1 Synchronous data data transfer from...

Страница 12: ...1 Baud rate Baud rate in bit s Transmission range 1200 m depending on data rate and cable type EIA RS 485 Settings 120 W termination and failsafe biasing 680 W Protection Installation Fault Tolerant...

Страница 13: ...e optic link is determined by the differ ence between the transmitter s output optical power min and the receiver input sensitivity max FX Fibre Bi di LC 60 Bi di LC 40 Bi di LC 20 Bi di MM LC 2 Fibre...

Страница 14: ...s are in operation NO 2 C Common C 3 NC Open no con tact with C when fibre opti cal links are in operation NC Position Direction Description Product marking 1 In R EIA RS 485 A R 2 In R EIA RS 485 B R...

Страница 15: ...erial port Data will be transmitted to the fibre link OFF RD Fibre link data Receive Flashing Receive data on the fibre link This frame is transmitted to the serial port OFF FL R Red Failure Link Remo...

Страница 16: ...witch asynchronous mode ON 1 2 3 4 5 6 7 8 RS 485 2 wire ON 1 2 3 4 5 6 7 8 RS 485 4 wire ON 1 2 3 4 5 6 7 8 300 bit s ON 1 2 3 4 5 6 7 8 1 200 bit s ON 1 2 3 4 5 6 7 8 2 400 bit s ON 1 2 3 4 5 6 7 8...

Страница 17: ...t control ON 1 2 3 4 5 6 7 8 Set status port at local fibre link error S3 DIP switch No termination and fail safe Termination with fail safe 4 wire Termination with fail safe 2 wire ON 1 2 3 4 ON 1 2...

Страница 18: ...ODW 630 F1 RS 485 transmitter on time after last data transition SW 1 SW 2 Transmitter ON ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 6 s ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 1 s ON 1 2 3 4 5 6 7 8 ON...

Страница 19: ...s form a bus structure where the termination is at the end points of the bus See diagrams for details of how this is done with RS 485 2 wire and 4 wire Termination ODW 630 F1 Slave unit Slave unit Sla...

Страница 20: ...cing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be mounted...

Страница 21: ...s from PLC master and slave to respective ODW 630 F1s Frames from PLC master that are correctly received in the ODW 630 F1 will be indicated by flashing TD LED Frames that are received via the fibre l...

Страница 22: ...ed frame during configuration of the PLC master Ensure that the correct protocol dependent configuration has been selected Flashing of the TD LED indicates that a start bit has been identified The def...

Страница 23: ...23 6651 22641...

Страница 24: ...REV B 6651 22641 2019 01 Westermo Network Technologies AB Sweden Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Отзывы: