Prepare the master units
Configure network, with master and slaves. Check that it is running correctly with
…
the electrical serial network.
Prepare the fibre optical network.
Redundant ring. Set switch S2:1 and 3 to ON and all others to OFF, at all units.
…
(If the status interface should be local, set S2:6 to ON)
Set present data rate with S1.
…
Connect the fibre links between the units.
…
Connect the power supply to all units.
…
• The Fibre links should be in operation, indicated by active CH 1 and CH 2 LED’s.
Connect each of the slaves to the port of corresponding ODW-622.
…
Connect the master to the port of one ODW-622.
…
The Redundant ring application is up and running.
…
Start up guide, redundant ring application