Safety

Before installation:

Read this manual completely and gather all information on the unit. Make sure 
that you understand it fully. Check that your application does not exceed the safe 
operating specifications for this unit. 
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is 
restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be 
possible to disconnect manually from the power supply. Ensure compliance to 
national installation regulations.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, 
follow the spacing recommendations (see Cooling section).

Before mounting, using or removing this unit:

Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this 
unit when connected to power supply.

Class 1 Laser Product

Do not look directly into fibre optical fibre port or any connected fibre although 
this unit is designed to meet the Class 1 Laser regulations.

Care recommendations

Follow the care recommendations below to maintain full operation of unit and to fulfil 
the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause 
damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not 
waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical 
part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo 
distributor office or Westermo Tech support.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port.
As long as no optical fibre is mounted on the connector, e.g. for storage, service or 
transportation, should the plug be applied.

!

!

!

Содержание ODW-610-F1

Страница 1: ...www westermo com ODW 610 F2 Fibre Optic Modem Industrial Converter PROFIBUS DP to Fibre Optic Link Repeater line and redundant ring...

Страница 2: ...2 6651 22611...

Страница 3: ...s for a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prio...

Страница 4: ...port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations Care recommendations Follow the care recommendations below to maintain full operation of unit and to fu...

Страница 5: ...special treatment It is very sensitive to dust and dirt If the fibre will be disconnected from the modem the protective hood on the transmitter receiver must be connected The protective hood must be...

Страница 6: ...ent in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Type Approval Compliance EMC EN 61000 6 1 Immun...

Страница 7: ...ion 200 ms 40 residual voltage 500 ms 70 residual voltage Mains freq 50 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radi...

Страница 8: ...r or when isolation of the electrical network is needed The maximum optical fibre distance depends on selected fibre transceiver and fibre type Data rate up to 12 Mbit s ODW 610 F2 converts PROFIBUS D...

Страница 9: ...he electrical port UnitS to which the addressed Slave is connected receives PROFIBUS DP data from the Slave UnitS converts slave data and transfers the slave frame via ring A The repeating of transfer...

Страница 10: ...only one optical fibre link end unit converted data will be transmitted in one direction via CH 1 only Data received from one ODW 610 F2 optical fibre port will be repeated through the other optical...

Страница 11: ...upplied with safety extra low voltage SELV It is designed to operate permanently over a wide input range and provided with two independent inputs allowing redundancy should either supply fail 9 positi...

Страница 12: ...all system delay The Redundant ring and Multidrop application Overall system delays differ see below Redundant ring one data exchange The data exchange between PROFIBUS DP master and slave via ODW 610...

Страница 13: ...s connected to PROFIBUS DP master and addressed slave Example Redundant ring one data exchange between master and one slave One PROFIBUS DP master and 11 slaves with data rate 1 5 Mbit s 12 ODW 610 F2...

Страница 14: ...t 1 0 Apeak Polarity Reverse polarity protected Redundant power input Yes Isolation to PROFIBUS DP and Status port Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded ca...

Страница 15: ...5 125 and 50 125 m Wavelength 1550 nm 1310 nm 1310 nm 1310 nm Transmitter Output optical power min max 5 0 dBm 5 0 dBm 15 8 dBm 20 14 dBm Receiver Input sensitivity 34 dBm max 34 dBm max 31 dBm max 31...

Страница 16: ...rminal PROFIBUS DP RS 485 D sub 3 position Direction Description No 1 NO Contact with C when link is in operation No 2 C Common No 3 NC Open no con tact with C when fibre link is in operation 4 positi...

Страница 17: ...2 out of opera tion CH 1 Channel ON Fibre link at port CH 1 in operation Data can be transmitted OFF Fibre link at port CH 1 out of opera tion DPR Receive PROFIBUS DP Flash Receive data on the electri...

Страница 18: ...ne optical fibre port CH 1 ON 1 2 3 4 5 6 7 8 Multidrop application mid unit Both optical fibre ports CH 1 CH 2 ON 1 2 3 4 5 6 7 8 Redundant ring application ON 1 2 3 4 5 6 7 8 65535 tbit interruption...

Страница 19: ...ON 1 2 3 4 5 6 7 8 6 faulty frame before data rate is seen as unidentified S1 No extended retry limit ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 7 faulty frame before data rate is seen as unidentified S1...

Страница 20: ...cing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be mounted...

Страница 21: ...e the fibre optical network Redundant ring Set switch S2 3 set to ON and all others to OFF at all units Connect the fibre links between the units Connect the power supply to all units The Fibre links...

Страница 22: ...twork Multidrop mid units CH 1 CH 2 Set switch S2 2 set to ON and all others to OFF Multidrop end units CH 1 only All switches should be set to OFF Connect the fibre links between the units Connect th...

Страница 23: ...onders at configuration of the PROFIBUS DP master If the time between transferred PROFIBUS DP frames is long it may be necessary to allow a longer time of interruption in receiving frames using DIP sw...

Страница 24: ...REV B 6651 22611 2019 01 Westermo Network Technologies AB Sweden Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Отзывы: