background image

11

6070-2001

Screw

Power

no.

supply

L

115*/230V

N

AC power

PE/Protective Earth

Connections MD-62  

Terminal connection (DCE)

(RS-232-C/V.24, 9-position female D-sub connector or 9-position screw-terminal)

Power connection 
MD-62 AC 

(3-position screw-terminal)

Power connection 
MD-62 DC

(2-position screw-terminal)

* MD-62 115V

Connection

Power

no.

Supply

1

– Voltage

2

+ Voltage

Direction

Pin

Screw

CCITT V.24

Description

no.

no.

Circuit no.

I

3

8

103

TD/Transmitted Data

O

2

7

104

RD/Received Data

I

7

6

105

RTS/Request To Send

O

8

5

106

CTS/Clear To Send

5

1 & 9

102

SG/Signal Ground

I

= Input  

O

= Output on MD-62

Fibre optic connection

MD-62

TX

RX

TX

RX

MD-62

Содержание MD-62 AC

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...re optic RS 232 V 24 Glasfaser Wandler RS 232 V 24 INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG 6070 2001 www westermo se MD 62 AC MD 62 DC Westermo Teleindustri AB 2000 Rev B Ga...

Страница 3: ...15V AC 24V DC 48V DC 15 10 15 10 50 50 15 25 Frequency 48 62Hz 48 62Hz Fuse F2 100mA S 100mA S 1 6A S 1 6A S 5x20 mm 5x20 mm 5x20 mm 5x20 mm Littelfuse Littelfuse Littelfuse Littelfuse Power consumpti...

Страница 4: ...cable Attenuation in connectors Attenuation in splice 0 2 0 4 dB Fusion 0 1 dB Mecanical 0 2 dB 50 125 16 6 dB 14 6 dB 62 5 125 18 6 dB 15 1 dB 100 140 25 9 dB 9 125 12 3 dB 50 125 10 7 dB 8 1 dB 62...

Страница 5: ...switches open the plastic case by removing the top cover Status signal Factory settings S1 Enabled ON 1 2 3 4 5 6 7 8 9 S1 Disabled ON 1 2 3 4 5 6 7 8 9 S1 ON 1 2 3 4 5 6 7 8 9 S2 ON 1 2 3 4 5 S2 ON 1...

Страница 6: ...62 AC 3 position screw terminal Power connection MD 62 DC 2 position screw terminal MD 62 115V Connection Power no Supply 1 Voltage 2 Voltage Direction Pin Screw CCITT V 24 Description no no Circuit n...

Страница 7: ...device is DTE If the most negative voltage is on pin 2 the device is DCE 3 The RS 232 cable is correct but it still does not work The LEDs may be helpful PWR The unit has power RD Data received from...

Страница 8: ...13 6070 2001 1 MD 62 DCE 1 DTE MD 62 DCE DCE MD 62 DCE 9 pole PC 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 20 21 25 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 20 21 25...

Страница 9: ...ions GmbH Bruchsaler Stra e 18 68753 Wagh usel Tel 49 0 7254 95400 0 Fax 49 0 7254 95400 9 E Mail westermo germany t online de Westermo Data Communications Ltd Solent Business Centre Millbrook Road We...

Страница 10: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: