background image

10

6645-2204

Fibre optic power budget

Model

MCW-211-MM 

xx2

MCW-211-SM 

SC15

MCW-211-SM 

LC15

MCW-211-SM 

LC40

Transmitted 
wavelength

1310 nm

1310 nm

1310 nm

1310 nm

Min. output 
power,  
transmitter

–19 dBm

–15 dBm

–15 dBm

–5 dBm

Max. output 
power,  
transmitter

–12 dBm

–8 dBm

–8 dBm

0 dBm

Input sensitivity, 
receiver

–31 dBm

–34 dBm

–31 dBm

–34 dBm

Min. power 
budget

12 dBm

19 dBm

16 dBm

29 dBm

Max. power 
budget

19 dBm

26 dBm

23 dBm

34 dBm

Recommended 
fibre cable and 
core / cladding 
diameter

Multimode 

50/125, 62.5/125

Singlemode 

9/125, 10/125

Singlemode 

9/125, 10/125

Singlemode 

9/125, 10/125 

Fibre type

Normal attenuation  

@ 1310 nm multimode

Normal attenuation  

@ 1310 nm singlemode

50/125

3.0 dBm/km

62,5/125

3.5 dBm/km

9/125

0.5 dBm/km

10/125

0.5 dBm/km

Attenuation in connectors / splices

Type

Normal attenuation

Connector

0.2 – 0.4 dBm

Fusion splice

0.1 dBm

Mechanical splice

0.2 dBm

Содержание MCW-211 SERIES

Страница 1: ...www westermo com MCW 211 Series Industrial Ethernet Media Converter...

Страница 2: ...2 6645 2204...

Страница 3: ...s for a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prio...

Страница 4: ...l fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations Care recommendations Follow the care recommendations below to maintain full operation of unit a...

Страница 5: ...leaned by the use of forced nitrogen and some kind of cleaning stick Recommended cleaning fluids Methyl ethyl isopropyl or isobutyl alcohol Hexane Naphtha Maintenance No maintenance is required as lon...

Страница 6: ...SM LC40 10 100Base T TX 1 port 100Base FX 1 port 3645 0050 MCW 211 MM LC2 10 100Base T TX 1 port 100Base FX 1 port Corrosive environment Notice This product has been successfully tested in a corrosio...

Страница 7: ...2 3 ANSI C63 4 FCC part 15 Enclosure Class A Conducted emission CISPR 16 2 1 DC power ports Class A Dielectric strength EN 60950 Signal port to other isolated ports 1 5 kVrms 50 Hz 1 min Power port t...

Страница 8: ...solation to Ethernet TX Ethernet FX Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 12 Shielded cable Not required Direction relative this unit Ethernet TX Electrical specificati...

Страница 9: ...RD 4 5 6 In Out RD 7 8 Direction relative this unit Ethernet FX SC ST or LC Position Direction Description Product marking Rx In Receive port Rx Tx Out Transmit port Tx Direction relative this unit Po...

Страница 10: ...Min power budget 12 dBm 19 dBm 16 dBm 29 dBm Max power budget 19 dBm 26 dBm 23 dBm 34 dBm Recommended fibre cable and core cladding diameter Multimode 50 125 62 5 125 Singlemode 9 125 10 125 Singlemo...

Страница 11: ...h Ethernet data is transmitted or received on TX interface LINK FX OFF No Ethernet link FX ON Good Ethernet link FX Flash Ethernet data is transmitted or received on FX interface FX DPX OFF Half dupex...

Страница 12: ...nections Mounting This unit should be mounted on 35 mm DIN rail which is horizontally mounted on a wall or cabinet backplate This unit uses convection cooling To avoid obstructing the airflow around t...

Страница 13: ...upports MDI X configuration Configuration DIP switches are accessible under the lid on top of the unit DIP switches are used to configure the unit DIP switch settings Before DIP switch settings Preven...

Страница 14: ...g ON 1 2 3 4 5 6 7 8 Flow control disabled S1 ON 1 2 3 4 5 6 7 8 Flow control enabled S1 Link fault forward settings ON 1 2 3 4 5 6 7 8 TX FX Link fault forward disabled S1 ON 1 2 3 4 5 6 7 8 TX FX Li...

Страница 15: ......

Страница 16: ...REV D 6645 2204 2018 11 Westermo Network Technologies AB Sweden Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Отзывы: