Danger! Do not open connected unit

1 2 3 4 5

LINE

CONNECTION

V.24/RS-232-C

CONNECTION

Switch settings

Transmitter (carrier) activated by

ON

1 2 3 4 5 6 7 8 9

S1

Always active

ON

1 2 3 4 5 6 7 8 9

S1

AUX

ON

1 2 3 4 5 6 7 8 9

S1

SRS

ON

1 2 3 4 5 6 7 8 9

S1

RFR

ON

1 2 3 4 5 6 7 8 9

S1

RTS

ON

1 2 3 4 5 6 7 8 9

S1

DTR

ON

1 2 3 4 5 6 7 8 9

S1

DTR and AUX

ON

1 2 3 4 5 6 7 8 9

S1

DTR and SRS

ON

1 2 3 4 5 6 7 8 9

S1

DTR and RFR

ON

1 2 3 4 5 6 7 8 9

S1

DTR and RTS

CTS controlled by

ON

1 2 3 4 5 6 7 8 9

S1

RTS

ON

1 2 3 4 5 6 7 8 9

S1

Always high

ON

1 2 3 4 5 6 7 8 9

S1

DCD

ON

1 2 3 4 5 6 7 8 9

S1

Factory settings

ON

1 2 3 4 5 6 7 8 9

S2

S1

ON

OFF

S1 Selection of signal activating transmitter (carrier)

Selection of signal controlling CTS

S2 Selection of power supply 115/230V AC

Switch settings MA-12

The MA-12 can through different switch settings be adapted to a variety of running con-
ditions. To set the switches, open the plastic case by placing and turning a screw-driver
between top and bottom at the rear of the case.

Содержание MA-12 AC

Страница 1: ...streckenmodem INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG 6012 2001 www westermo se MA 12 AC MA 12 DC Westermo Teleindustri AB 1999 REV A Galavanic Isolation CE Approved Balance...

Страница 2: ...sformer supply Insulation voltage 1500V Overvoltage protection N t Breakdown voltage 440V at 230V AC and 220V at 115V AC Interface 2 Breakdown voltage transmitter 15V and receiver 5 8V Surge capacity...

Страница 3: ...9 S1 DTR and RFR ON 1 2 3 4 5 6 7 8 9 S1 DTR and RTS CTS controlled by ON 1 2 3 4 5 6 7 8 9 S1 RTS ON 1 2 3 4 5 6 7 8 9 S1 Always high ON 1 2 3 4 5 6 7 8 9 S1 DCD ON 1 2 3 4 5 6 7 8 9 S1 Factory sett...

Страница 4: ...sub female Direction 1 Pin CCITT V 24 Description no Circuit number I 2 103 TD Transmitted Data O 3 104 RD Received Data I 4 105 RTS Request to Send O 5 106 CTS Clear to Send O 6 107 DSR Data Set Rea...

Страница 5: ...ons according to MA 12 AC 1 2 3 4 5 1 2 3 POWER 12 36V DC LINE CONNECTION V 24 RS 232 C CONNECTION Transmission range interface 2 Cable Transmission rate bit s 42pF m 600 1200 2400 4800 9600 19200 384...

Страница 6: ...n RTS Indicates the carrier control status A good way to check the MA 12 is to carry out a loop back test Connect T to R and T to R Connect the RS 232 port to a terminal When keys are pressed on the t...

Страница 7: ...13 6012 2001 OWN COMMENTS...

Страница 8: ...ermo Teleindustri AB S 640 40 Stora Sundby Sweden Phone 46 16 612 00 Fax 46 16 611 80 E mail info westermo se Westermo Web site www westermo se Westermo Teleindustri AB have distributors in several co...

Отзывы: