Содержание Lynx

Страница 1: ... Westermo Teleindustri AB www westermo com User Guide 6643 22601 Industrial Ethernet 10 port Switch Lynx L110 F2G EX L210 F2G EX WeOS ...

Страница 2: ... any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo can be found at the following Internet address http www westermo com Safety Warning Do not open connected unit Hazardous voltage may occur within this unit when connected t...

Страница 3: ...plies with the relevant requirements of EN 60079 0 and EN 60079 15 All external connections to the equipment and where applicable the SFP modules must not be inserted or removed unless either the area in which the equipment is installed is known to be non hazardous or the circuits connected have been de energized The network cables once installed must be properly fixated by the use of cable ties o...

Страница 4: ...Multimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceivers 1 Gbit 1100 0144 GMLC550 SX Multimode LC Connector 550 m 850 nm SX 1100 0147 GMLC2 SX Multimode LC Connector 2 km 1310 nm SX 1100 0141 GSLC10 LX Singlemode LC Connector 10 km 1310 nm LX 1100 0142 GSLC50 XD Singlemode LC Connector 50 km 1550 nm XD 1100 0143 GSLC80 ZX Singlemode...

Страница 5: ...N 60079 0 und EN 60079 15 erfüllt installiert werden Alle äußeren Anschlüsse des Gerätes und auch die SFP Module dürfen nur dann verbunden oder getrennt werden wenn entweder der Bereich in dem das Gerät installiert ist nachweislich ungefährlich ist oder die verbundenen Stromkreise spannungsfrei sind Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder ähnlichem Material or...

Страница 6: ... A Multimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceiver 1 Gbit 1100 0144 GMLC550 SX Multimode LC Anschluss 550 m 850 nm SX 1100 0147 GMLC2 SX Multimode LC Anschluss 2 km 1310 nm SX 1100 0141 GSLC10 LX Singlemode LC Anschluss 10 km 1310 nm LX 1100 0142 GSLC50 XD Singlemode LC Anschluss 50 km 1550 nm XD 1100 0143 GSLC80 ZX Singlemo...

Страница 7: ...ables à EN 60079 0 et EN 60079 15 Toutes les connexions externes à l équipement et le cas échéant les modules SFP ne doivent pas être insérés ou retirés sauf si la zone dans laquelle l équipement est installé est reconnue comme non dangereuse ou si les circuits raccordés sont hors tension Une fois les câbles réseau installés ils doivent être correctement fixé grâce à des attaches de câbles ou autr...

Страница 8: ...Di A multimode Bi Di 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B multimode Bi Di 2 km 1550 nm TX 1310 nm RX Transmetteurs SFP 1 Gbit 1100 0144 GMLC550 SX multimode connecteur LC 550 m 850 nm SX 1100 0147 GMLC2 SX multimode connecteur LC 2 km 1310 nm SX 1100 0141 GSLC10 LX monomode connecteur LC 10 km 1310 nm LX 1100 0142 GSLC50 XD monomode connecteur LC 50 km 1550 nm XD 1100 0143 SLC80 monomo...

Страница 9: ...art 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a ...

Страница 10: ...idential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6 4 Electromagnetic compatibility Emission for industrial environments 2007 EN 55024 Information technology equipment Immunity 1998 A1 2001 A2 2003 EN 55022 Information technology equipment Emission 2006 A1 2007 EN 50121 4 Railway applications Electromagnetic compatibility Emiss...

Страница 11: ... emission EN 55022 Enclosure Class A FCC Part 15 Class A Conducted RF emission EN 55022 Power port Class B Signal ports Class B Dielectric strength EN 60950 1 Power port to all other ports 1 5 kVrms 50 Hz 1 min Signal ports to all other ports 1 5 kVrms 50 Hz 1 min Environmental Temperatures Operating 40 to 70 C 40 to 158 F Storage and transport 50 to 85 C 58 to 185 F Humidity Operating 5 to 95 rel...

Страница 12: ...environments and places with heavy electrical interference require the use of a reliable media Lynx provides a number of solutions using fibre optic transceivers Multi or singlemode transceivers can be used to build point to point or redundant ring networks with ranges up to 120 km between each switch Our BIDI transceiver which transmits and receives data on a single fibre can be used in applicati...

Страница 13: ... range Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails Conductive housing Yes Number of ports 8 Refer to Safety section To minimise the risk of interference a shielded cable is recommended when the cable is...

Страница 14: ...rmat 8 data bits no parity 1 stop bit no flow control Circuit type SELV Connection 2 5 mm jack use only Westermo cable 1211 2027 SFP Transceivers Supported transceivers Firmware prior to 4 4 0 accepts Westermo branded transceivers only From 4 5 0 other transceivers are accepted with a notice and the unit will no longer be UL approved Temp specifications are also depending on the used transeivers N...

Страница 15: ...ee user manual for proven transient protection LED Indicators for details see page 13 Power connection for details see page 9 and 12 SFP transceivers for details see page 4 9 and 10 I O connection for details see page 10 and 12 Console port for details see page 10 and 12 Cable 1211 2027 Connection to console port The console port can be used to connect to the CLI Command Line Interface The followi...

Страница 16: ... Alarm relay status contact Iin 80 mA max No 3 Digital in Input Digital in Uin 60 VDC max No 4 Digital in Input Digital in Iin 2 mA max The Status output is a potential free opto isolated normally closed solid state relay This can be configured to monitor various alarm events within the Lynx unit see WeOS Management Guide An external load in series with an external voltage source is required for p...

Страница 17: ...C1 OFF Unit has no power GREEN Power OK on DC1 RED Power failure on DC1 DC2 OFF Unit has no power GREEN Power OK on DC2 RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch USR1 OFF Configurable see WeOS Management Guide GREEN RED 1 to 10 OFF No Lin...

Страница 18: ...ated DIN clip Removal Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Spacing is recommended for the use of unit in full operating temperature range and service life 10mm 10mm Removing Lynx with integrated DIN clip Press down the support at ...

Страница 19: ...anagement Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Configure the unit via Web browser The unit can easily be configured via a Web browser Open the link http 192 168 2 200 in your web browser and you will be prompted with a Login screen ...

Страница 20: ... now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables The ON LED will stop flashing This initiates the factory reset process and after approximately 1 minute the unit will restart with factory default settings When the switch has booted ...

Страница 21: ...21 6643 22601 Dimensions Measurements are stated in millimeters 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1 ...

Страница 22: ......

Страница 23: ......

Страница 24: ...ce infos westermo fr www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 1...