![Westermo Lynx SERIES Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/westermo/lynx-series/lynx-series_user-manual_960352021.webp)
Ethernet TX
Electrical specification
IEEE std 802.3
Data rate
10 Mbit/s, 100 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Circuit type
TNV-1
Transmission range
Up to 150 m with CAT5e cable or better
Isolation
All other ports
Connection
RJ-45, auto MDI/MDI-X
Cabling
Shielded CAT5e or better is recommended
Shielded cable
Not required, except when installed in railway application as signalling and
telecommunications apparatus and located close to rails
a
Conductive chassis
Yes
Number of ports
4
a
To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.
Ethernet SFP pluggable connections (FX or TX)
Electrical specification
IEEE std 802.3
Data rate
100 Mbit/s, 1000 Mbit/s, transceivers supported
Duplex
Full or Auto, depending on transceiver
Transmission range
Depending on transceiver, see datasheet for SFP transceivers
Connection
SFP slot holding fibre transceiver or copper transceiver
Number of ports
1 or 2
I/O connection, Relay output
Maximum voltage/current
60 VDC/80 mA
Connect resistance
Maximum 30
Ω
Isolation
To all other ports
Connector
Detachable screw terminal
Conductor cross section
0.14 - 1.5 mm² (AWG 28 - 16)
Stripping length cable
7 mm
Tightening torque, terminal
screw
0.22 - 0.25 Nm
Tightening torque, screw
flange
0.3 Nm
Lynx L106/206-F2G
21
Содержание Lynx SERIES
Страница 1: ...www westermo com OS Lynx L106 206 F2G Industrial Ethernet 6 Port Switch...
Страница 26: ...Lynx L106 206 F2G...