www.westermo.com

Lynx L210-F2G-EX 

Industrial Ethernet 10-port Switch

Содержание Lynx L210-F2G-EX

Страница 1: ...www westermo com Lynx L210 F2G EX Industrial Ethernet 10 port Switch ...

Страница 2: ...2 6643 22601 ...

Страница 3: ...o can be found at www westermo com Software tools Related software tools are available at www westermo com support software tools License and copyright for included Free Libre Open Source Software This product includes software developed by third parties including Free Libre Open Source Software FLOSS The specific license terms and copyright associated with the software are included in each softwa...

Страница 4: ...s a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important inf...

Страница 5: ...oss sectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DINrail must be connected to protective earth Upon removal of the product ensure that the protective earthing conductor or the connection to earth via the DIN rail is disconnected last WARNING PROTECTIVE FUSE It must be possible to disconnect manually from the power supply Ensure compliance to...

Страница 6: ...e damages to internal electronic parts by discharging your body to a grounding point e g use a wrist strap CAUTION CLASS 1 LASER PRODUCT Do not look directly into a fibre optical port or any connected fibre although the product is designed to meet the Class 1 Laser regulations and complies with 21 CFR 1040 10 and 1040 11 CAUTION HANDLING OF SFP TRANSCEIVERS SFP transceivers are supplied with plugs...

Страница 7: ...roduct is disposed of correctly you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health which could be caused by inappropriate disposal Care recommendations Follow the care recommendations below to maintain full operation of product and to fulfill the warranty obligations Do not drop knock or shake the product Rough handling abo...

Страница 8: ...evant requirements of EN 60079 0 and EN 60079 15 All external connections to the equipment and where applicable the SFP modules must not be inserted or removed unless either the area in which the equipment is installed is known to be non hazardous or the circuits connected have been de energized The network cables once installed must be properly fixated by the use of cable ties or similar to reduc...

Страница 9: ...Multimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceivers 1 Gbit 1100 0144 GMLC550 SX Multimode LC Connector 550 m 850 nm SX 1100 0147 GMLC2 SX Multimode LC Connector 2 km 1310 nm SX 1100 0141 GSLC10 LX Singlemode LC Connector 10 km 1310 nm LX 1100 0142 GSLC50 XD Singlemode LC Connector 50 km 1550 nm XD 1100 0143 GSLC80 ZX Singlemode...

Страница 10: ...0079 15 erfüllt installiert werden Alle äußeren Anschlüsse des Gerätes und auch die SFP Module dürfen nur dann verbunden oder getrennt werden wenn entweder der Bereich in dem das Gerät installiert ist nachweislich ungefährlich ist oder die verbundenen Stromkreise spannungsfrei sind Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder ähnlichem Material ordnungsgemäß befest...

Страница 11: ... A Multimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceiver 1 Gbit 1100 0144 GMLC550 SX Multimode LC Anschluss 550 m 850 nm SX 1100 0147 GMLC2 SX Multimode LC Anschluss 2 km 1310 nm SX 1100 0141 GSLC10 LX Singlemode LC Anschluss 10 km 1310 nm LX 1100 0142 GSLC50 XD Singlemode LC Anschluss 50 km 1550 nm XD 1100 0143 GSLC80 ZX Singlemo...

Страница 12: ... et EN 60079 15 Toutes les connexions externes à l équipement et le cas échéant les modules SFP ne doivent pas être insérés ou retirés sauf si la zone dans laquelle l équipement est installé est reconnue comme non dangereuse ou si les circuits raccordés sont hors tension Une fois les câbles réseau installés ils doivent être correctement fixé grâce à des attaches de câbles ou autre élément semblabl...

Страница 13: ...iDi A multimode Bi Di 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B multimode Bi Di 2 km 1550 nm TX 1310 nm RX Transmetteurs SFP 1 Gbit 1100 0144 GMLC550 SX multimode connecteur LC 550 m 850 nm SX 1100 0147 GMLC2 SX multimode connecteur LC 2 km 1310 nm SX 1100 0141 GSLC10 LX monomode connecteur LC 10 km 1310 nm LX 1100 0142 GSLC50 XD monomode connecteur LC 50 km 1550 nm XD 1100 0143 SLC80 monom...

Страница 14: ...radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Corrosive environment Notice This product has been successfully tested in a corrosion test according to IEC 60068 2 60 method 3 This means that the product meets the requirements to be placed in an envi...

Страница 15: ...s used in safety critical applications such as tunnels traffic signal control and railway systems Installations in harsh environments and places with heavy electrical interference require the use of a reliable media Lynx provides a number of solutions using fibre optic transceivers Multi or singlemode transceivers can be used to build point to point or redundant ring networks with ranges up to 120...

Страница 16: ... mA Data rate 10 100 Mbit s No 2 TD In Out Transmitted Received data No 3 RD In Out Transmitted Received data No 4 Not Connected No 5 Not Connected No 6 RD In Out Transmitted Received data No 7 Not Connected No 8 Not Connected Shield Connected to PE Galvanically isolated via signal transformers and capacitively isolated to GND PE through a 2kV 1000pF capacitor LED Indicators Power connection SFP t...

Страница 17: ...external supply current capability for proper startup Ethernet TX Electrical specification IEEE std 802 3 Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type TNV 1 Transmission range Up to 150 m with CAT5e cable or better Isolation to All other ports Connection RJ 45 auto MDI MDI X Shielded cable Shielded CAT5e or better is recommended Conductive housing Y...

Страница 18: ... Digital input Maximum voltage load current 60 VDC 2 mA Voltage levels Logic one 12V Logic zero 1V Isolation to All other ports Connection Detachable screw terminal Conductor cross section 0 14 1 5 mm2 AWG 28 16 Stripping length cable 7 mm Tightening torque terminal screw 0 22 0 25 Nm Tightening torque screw flange 0 3 Nm Console Electrical specification TTL level Data rate 115 2 kbit s Data forma...

Страница 19: ...lcohol hexane or naphtha Supported transceivers Firmware prior to 4 4 0 accepts Westermo branded transceivers only From 4 5 0 other transceivers are accepted with a notice and the product will no longer be UL approved Temp specifications are also depending on the used transeivers Note To comply with UL 62368 1 only UL recognized SFP transceivers should be used CAUTION HANDLING OF SFP TRANSCEIVERS ...

Страница 20: ... 30 MHz to 6 5 GHz Conducted RF emission CISPR 16 2 1 ANSI C63 4 Power port Class B Signal ports Dielectric strength UL 62368 1 Power port to all other ports 1 5 kVrms 50 Hz 1 min Signal ports to all other ports Environmental Temperatures EN 60068 2 1 EN 60068 2 2 Operating 40 to 70 C 40 to 158 F Storage and transport 50 to 85 C 58 to 185 F Humidity EN 60068 2 30 Operating 5 to 95 relative humidit...

Страница 21: ...ermo cable 1211 2027 2 Connect cable to your computer USB port if drivers are needed they can be downloaded from our Web page 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information about the CLI see the WeOS management guide Bottom view Console Port I O connection Accessories Description Art no Westermo console cable 1211 2027 RJ45 ...

Страница 22: ...larm relay status contact Iin 80 mA max No 3 Digital in Input Digital in Uin 60 VDC max No 4 Digital in Input Digital in Iin 2 mA max The Status output is a potential free opto isolated normally closed solid state relay This can be configured to monitor various alarm events within the Lynx product see WeOS Management Guide An external load in series with an external voltage source is required for ...

Страница 23: ...resent on DC1 DC2 OFF Product has no power GREEN Voltage present on DC2 RED No voltage present on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Product configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Product elected as RSTP STP root switch USR1 OFF Configurable see WeOS Management Guide GREEN RED 1 to 10 OFF No Link GREEN Link established GREEN FLASH ...

Страница 24: ...t uses convection cooling To avoid obstructing the airflow around the product use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the product Spacing is recommended for the use of product in full operating temperature range and service life 10mm 10mm This product has an integrated DIN clip To remove the product press down the support at the ba...

Страница 25: ...vailable in the chapter The Command Line Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note Version of IP Config tool must be 10 3 0 or higher Configuration Configure the product via web browser The product can easily be configured via a web browser Open the link http 192 168 2 200 in your web browser and you will be pr...

Страница 26: ...u now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables The ON LED will stop flashing This initiates the factory reset process and after approximately 1 minute the product will restart with factory default settings When the switch has boo...

Страница 27: ...27 6643 22601 Dimensions Measurements are stated in millimeters 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1 ...

Страница 28: ...REV I 6643 22601 2020 12 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com ...